• Title/Summary/Keyword: Local response

Search Result 1,587, Processing Time 0.028 seconds

Seismic response of 3D steel buildings with hybrid connections: PRC and FRC

  • Reyes-Salazar, Alfredo;Cervantes-Lugo, Jesus Alberto;Barraza, Arturo Lopez;Bojorquez, Eden;Bojorquez, Juan
    • Steel and Composite Structures
    • /
    • v.22 no.1
    • /
    • pp.113-139
    • /
    • 2016
  • The nonlinear seismic responses of steel buildings with perimeter moment resisting frames (PMRF) and interior gravity frames (IGF) are estimated, modeling the interior connections first as perfectly pinned (PPC), and then as partially restrained (PRC). Two 3D steel building models, twenty strong motions and three levels of the PRC rigidity, which are represented by the Richard Model and the Beam Line Theory, are considered. The RUAUMOKO Computer Program is used for the required time history nonlinear dynamic analysis. The responses can be significantly reduced when interior connections are considered as PRC, confirming what observed in experimental investigations. The reduction significantly varies with the strong motion, story, model, structural deformation, response parameter, and location of the structural element. The reduction is larger for global than for local response parameters; average reductions larger than 30% are observed for shears and displacements while they are about 20% for bending moments. The reduction is much larger for medium- than for low-rise buildings indicating a considerable influence of the structural complexity. It can be concluded that, the effect of the dissipated energy at PRC should not be neglected. Even for connections with relative small stiffness, which are usually idealized as PPC, the reduction can be significant. Thus, PRC can be used at IGF of steel buildings with PMRF to get more economical construction, to reduce the seismic response and to make steel building more seismic load tolerant. Much more research is needed to consider other aspects of the problem to reach more general conclusions.

A Study on Policy Model of Promotion Project for Local Industry for Endogenous Rural Development (내생적 지역발전을 위한 향토산업육성사업의 정책모형에 관한 연구)

  • Son, Eun-Il;Satoshi, Hoshino
    • Journal of Korean Society of Rural Planning
    • /
    • v.18 no.4
    • /
    • pp.1-12
    • /
    • 2012
  • This study postulates a partial mediation model(study model I) and a whole mediation model(study model II) to examine the effect on endogenous rural development of local innovation capability strengthening in the local industry promotion project, the establishment of promotion system, and the revitalization of local economy. To accomplish study purposes, 169 response samples from 85 project groups which drive the local industry promotion project were verified using SPSS 12.0 and AMOS 5.0. The results showed that in the partial mediation model, the local innovation capability strengthening had a significantly positive effect on the establishment of promotion system, the establishment of promotion system had a significant effect on the revitalization of local economy, and the revitalization of local economy had a significant effect on the endogenous rural development, while the establishment of promotion system and local innovation capability strengthening didn't have effect on the endogenous rural development. In the whole mediation model, the local innovation capability strengthening had a significant effect on the revitalization of local economy, the establishment of promotion system on the revitalization of local economy, and the revitalization of local economy on the endogenous rural development. According to the verifications of study model I and II, the endogenous rural development is achieved after the revitalization of local economy through the establishment of promotion system and the local innovation capability strengthening. From these results, this study presents suggestions, limits of study and directions in the future study.

Efficient equalizer design for multi-carrier transmission system in local area access (가입자 지역 다중반송파 전송시스템의 등화기 구현)

  • 최재호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.3
    • /
    • pp.32-38
    • /
    • 2001
  • Multi-carrier data transmission system performance is mostly limited by Inter- symbol-interference that is caused by a dispersive characteristic of the transmission channel. In order to enhance the system performance to meet the service requirements of local access, the channel impulse response shortening method incorporated with a channel frequency response compensation method is proposed. For a fast and efficient implementation of the equalizer proposed, Kalman and LMS algorithms are successively used. To verify the channel equalization performance, a set of computer simulation is performed on a filter bank based multitone system operating in a typical high-speed local area data transmission environment. The results showed us a comparable signal-to-interference improvement over the conventional multitone equalization scheme.

  • PDF

Stringer Shape Optimization of Aircraft Panel Assembly Structure (항공기 패널 조립체 구조물의 스트링거 형상 최적화)

  • Kim Hyoung-Rae;Park Chan-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.136-142
    • /
    • 2006
  • Optimization of the aircraft panel assembly constructed by skin and stringers is investigated. For the design of panel assembly of the aircraft structure, it is necessary to determine the best shape of the stringer which accomplishes lowest weight under the condition of no instability. A panel assembly can fail in a variety of instability modes under compression. Overall modes of flexure or torsion can occur and these can interact in a combined flexural/torsion mode. Flexure and torsion can occur symmetrically or anti-symmetrically. Local instabilities can also occur. The local instabilities considered in this paper are buckling of the free and attached flanges, the stiffener web and the inter-rivet buckling. A program is developed to find out critical load for each instability mode at the specific stringer shape. Based on the developed program, optimization is performed to find optimum stringer shape. The developed instability analysis program is not adequate for sensitivity analysis, therefore RSM (Response Surface Method) is utilized instead to model weight and instability constraints. Since the problem has many local minimum, Genetic algorithm is utilized to find global optimum.

Damage identification of vehicle-track coupling system from dynamic responses of moving vehicles

  • Zhu, Hong-Ping;Ye, Ling;Weng, Shun;Tian, Wei
    • Smart Structures and Systems
    • /
    • v.21 no.5
    • /
    • pp.677-686
    • /
    • 2018
  • The structural responses are often used to identify the structural local damages. However, it is usually difficult to gain the responses of the track, as the sensors cannot be installed on the track directly. The vehicles running on a track excite track vibration and can also serve as response receivers because the vehicle dynamic response contains the vibration information of the track. A damage identification method using the vehicle responses and sensitivity analysis is proposed for the vehicle-track coupling system in this paper. Different from most damage identification methods of vehicle-track coupling system, which require the structural responses, only the vehicle responses are required in the proposed method. The local damages are identified by a sensitivity-based model updating process. In the vehicle-track coupling system, the track is modeled as a discrete point supported Euler-Bernoulli beam, and two vehicle models are proposed to investigate the accuracy and efficiency of damage identification. The measured track irregularity is considered in the calculation of vehicle dynamic responses. The measurement noises are also considered to study their effects to the damage identification results. The identified results demonstrate that the proposed method is capable to identify the local damages of the track accurately in different noise levels with only the vehicle responses.

Progressive collapse vulnerability in 6-Story RC symmetric and asymmetric buildings under earthquake loads

  • Karimiyan, Somayyeh;Kashan, Ali Husseinzadeh;Karimiyan, Morteza
    • Earthquakes and Structures
    • /
    • v.6 no.5
    • /
    • pp.473-494
    • /
    • 2014
  • Progressive collapse, which is referred to as the collapse of the entire building under local damages, is a common failure mode happened by earthquakes. The collapse process highly depends on the whole structural system. Since, asymmetry of the building plan leads to the local damage concentration; it may intensify the progressive collapse mechanism of asymmetric buildings. In this research the progressive collapse of regular and irregular 6-story RC ordinary moment resisting frame buildings are studied in the presence of the earthquake loads. Collapse process and collapse propagation are investigated using nonlinear time history analyses (NLTHA) in buildings with 5%, 15% and 25% mass asymmetry with respect to the number of collapsed hinges and story drifts criteria. Results show that increasing the value of mass eccentricity makes the asymmetric buildings become unstable earlier and in the early stages with lower number of the collapsed hinges. So, with increasing the mass eccentricity in building, instability and collapse of the entire building occurs earlier, with lower potential of the progressive collapse. It is also demonstrated that with increasing the mass asymmetry the decreasing trend of the number of collapsed beam and column hinges is approximately similar to the decreasing trend in the average story drifts of the mass centers and stiff edges. So, as an alternative to a much difficult-to-calculate local response parameter of the number of collapsed hinges, the story drift, as a global response parameter, measures the potential of progressive collapse more easily.

Systematic Forecasting Bias of Exit Poll: Analysis of Exit Poll for 2010 Local Elections (출구조사의 체계적인 예측 편향에 대한 분석: 2010년 지방선거 출구조사를 중심으로)

  • Kim, Young-Won;Choi, Yun-Jung
    • Survey Research
    • /
    • v.12 no.3
    • /
    • pp.25-48
    • /
    • 2011
  • In this paper, we overview the sample design, sampling error, non-response rate and prediction errors of the exit poll conducted for 2010 local elections and discusses how to detect a prediction bias in exit poll. To investigate the bias problem in exit poll in regional(Si-Do) level, we analyze exit poll data for 2007 presidential election and 2006 local elections as well as 2010 local elections in Korea. The measure of predictive accuracy A proposed by Martin et al.(2005) is used to assess the exit poll bias. The empirical studies based on three exit polls clearly show that there exits systematic bias in exit poll and the predictive bias of candidates affiliated to conservative party (such as Hannara-Dang) is serious in the specific regions. The result of this study on systematic bias will be very useful to improving the exit poll methodology in Korea.

  • PDF

Analysis of Design Wind Load Level for System Supports Considering Local Basic Wind Velocity and Construction Period (지역별 기본풍속과 공사기간을 반영한 시스템 동바리 설계 풍하중 분석)

  • Lee, Sun-Woo;Won, Jeong-Hun;Mha, Ho-Seong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.53-61
    • /
    • 2014
  • This study evaluated wind loads considering a local basic wind velocity and construction periods to define the level of applied wind loads for system supports. Structural responses of system supports were examined and compared to those of system supports with the level of wind loads following various standards and specifications for permanent and temporary structures. And, the maximum combined stress ratios were estimated to evaluate the structural safety of a considered system support. From results, it was found that the wind load level should be applied in accordance with construction periods when estimating the safety of system supports. Looking into the response by change of the basic wind velocity according to local regions, it is no need to consider wind loads in regions with the basic wind velocity of 30 m/s. However, it was analyzed that wind loads should be considered in the regions with the basic wind velocity of 40 m/s or above. In addition, wind loads should be considered in designing system supports located at the region with the basic wind velocity of 35 m/s starting from construction period of 1.5 years. The standard specification for temporary work was analyzed as an incorrect standard in evaluating wind loads, since it underestimated the response of system supports in accordance with the local basic wind velocity and construction periods.

Profile Analysis on Signal Measured Local Ice Load during Icebreaking in Arctic Sea (북극해에서의 쇄빙시 국부 빙하중 계측 신호에 대한 파형 분석)

  • Jeon, Young-Ju;Rim, Chae-Whan;Lee, Tak-Kee
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • The aim of this study is to investigate the characteristics on the profile of local ice load acting on side shell of port side in bow part due to broken ice during icebreaking of ships in ice covered waters. The first Korean icebreaking research vessel 'ARAON' had a sea ice field trial in the Arctic Sea during early August, 2010, and the signals due to local ice impact measured from several strain gauges installed at bow part were gathered. It is known that these data with structural response characteristics due to local ice impact have some different characteristics with a typical hydraulic impact pressure - time history. In this study, the time history on the measured signals was analyzed and the characteristic values were presented using non-dimensional parameters.

Optimal Design Method of Dynamic Vibration Absorber to Reduce Resonant Vibration Response of Ship Local Structure (선박 국부구조의 공진응답 저감을 위한 동흡진기 최적 설계 방법)

  • Kwon, Hyuk;Cho, Daeseung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.3
    • /
    • pp.134-140
    • /
    • 2022
  • Ship local structure sometimes experiences severe vibration due to the resonance with an excitation force generated by the propulsion system. In that case, the installation of dynamic vibration absorber such as Tuned Mass Damper (TMD) on the structure can be considered as an effective alternative countermeasure to reduce the troublesome vibration if structural modification or change of excitation frequencies is difficult. Meanwhile, the conventional optimal design method of TMD premises the target structure exposed on an excitation force without the constraint of its magnitude and frequency range. However, the frequencies of major ship excitation forces due to propulsion system are normally bounded and its magnitude is varied according to its operation speed. Hence, the optimal design of TMD to reduce the resonant vibration of ship local structure should be differently approached compared with the conventional ones. For the purpose, this paper proposes an optimal design method of TMD considering maximum frequency and magnitude variation of a target harmonic excitation component. It is done by both lowering the resonant response at the 1st natural frequency and locating the 2nd natural frequency over maximum excitation frequency for the idealized 2 degree of freedom system consisted of the structure and the TMD. For the validation of the proposed method, a numerical design case of TMD for a ship local structure exposed on resonant vibration due to a propeller excitation force is introduced and its performance is compared with the conventionally designed one.