• Title/Summary/Keyword: Local fouling

Search Result 12, Processing Time 0.023 seconds

Liquid Velocity and Local Fouling in Coagulation-submerged Microfiltration Module for Drinking Water Treatment (정수처리를 위한 응집-침지식 정밀여과 모듈의 유체유속 및 국부오염)

  • Choi, Youngkeun;Kim, Hyun-Chul;Noh, Soohong
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.268-275
    • /
    • 2015
  • Effects of aeration intensity on local fouling were investigated in submerged membrane modules. Higher liquid velocities were observed at the section with the lower fiber packing density. The liquid velocity is increased with increasing the gas-liquid injection factor. The high shear stress coincided with the high liquid velocity. The shear stress increases with the increasing of gas-liquid injection factor and the liquid velocity improves with the increasing of gas-liquid injection factor. Irreversible fouling resistance ($R_{ir}$) of the fiber position is significant in a local region of high suction pressure near the suction point of the fiber (position 1). The ratio of $R_{ir}/R_m$ and $R_{ir}/R_r$ of position 1 was highest compared to the position 2 and 3. Irreversible fouling resistances results confirmed the preferential deposition of foulants near the suction part of the fiber where the local suction pressure is the highest and correspondingly, more particles are accumulated to the membrane surface. The effects of local fouling along the fiber length are significant factors to optimize the design of submerged modules.

Particulate Two-Phase Flow Analysis for Fouling Prediction(I)-Design of Hot Wind Tunnel and Its Performance Experiment- (파울링 예측을 위한 가스-입자 이상 유동 해석(1)-고온 풍동 설계 및 성능실험-)

  • Ha, Man-Yeong;Lee, Dae-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3695-3705
    • /
    • 1996
  • We designed the hot wind tunnel to reproduce the conditions of utility boiler and carried out its performance test, in order to investigate the particulate two-phase flow behaviour, the fouling and heat transfer characteristics to the heat exchanger. The hot wind tunnel introduces the control system to control the temperature in the test section. The particle is injected into the hot gas stream. The fouling probe (cylindrical tube) is positioned normal to the particulate gas-particle two-phase flow and cooled by the air. The temperature of gas and cooling air, and temperature in the fouling probe are measured as a function of time, giving the local and averaged heat transfer and fouling factor. The shape of particulate deposition adhered to the fouling probe is also observed.

A Study on the Fouling Effect of Geothermal Water Scale in In-line tube Bank (직렬 관군에서 지열수스케일의 파울링 영향에 관한연구)

  • 윤석범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.131-139
    • /
    • 1999
  • An experimental study was conducted to investigate the fouling effects of geothermal water scale deposited onto a heating surface upon its forced convection heat transfer characteristics. Scales deposited onto the heating surfaces of heat exchangers seriously reduce the heat transfer perfor-mance and also increase the hydrodynamic drag. Accordingly fouling is an important problem in the design and operation of heat exchangers. The cylinders were settled in tandem with equal dis-tance between neighbouring cylinders and only the test cylinder was heated under the condition of constant heat flux. The Reynolds number was varied from 13000310 through 50003100. It is found that the heat transfer of the in-line tube banks greatly varies with the fouling of geothermal water scale especially its scale height. Further the local and average Nusselt numbers strongly depend upon the cylinder spacing and the Reynolds number.

  • PDF

A Study on the Effect of Scale Roughness attached Surface of Heat Exchangers (표면에 부착되는 스케일의 조도가 열교환기 성능에 미치는 영향에 관한 연구)

  • Kim, Min-Soo;Choi, Nag-Jung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.235-242
    • /
    • 2010
  • An experimental investigation has been conducted to clarify roughness effects of geothermal water scale deposited onto a heating surface upon its forced convection heat transfer characteristics. Examined was a circular cylinder, on which particles of silica scale having five different sizes are uniformly distributed. The Reynolds number was varied from 13000 through 50000. Local and mean heat transfer characteristics were measured as functions of particle size and Reynolds number. Subsequently the mean fouling resistance was estimated from those results, and its characteristics are clarified. It was found that the heat transfer of cylinders greatly varies with the fouling of geothermal water scale, especially its scale height. Further, the local and average Nusselt numbers strongly depend upon the cylinder spacing and the Reynolds number.

Heat Transfer Enhancement in Cross-flow Heat Exchanger Using Vortex Generator (와류발생기를 사용한 직교류 열교환기의 열전달 촉진)

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil;Lee, Sang-Sub;Kim, Byeong-Chae;Park, Dong-Seong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.61-66
    • /
    • 2003
  • Fouling is very serious problem in heat exchanger because it rapidly deteriorates the performance of heat exchanger. Cross-flow heat exchanger with vortex generators is developed, which enhance heat transfer and reduce fouling. In the present heat exchanger, shell and baffle are removed from the conventional shell-and-tube heat exchanger. The naphthalene sublimation technique is employed to measure the local heat transfer coefficients. The experiments are performed for single circular tube, staggered array tube bank and in-line array tube bank with and without vortex generators. Local and average Nusselt numbers of single tube and tube bank with vortex generator are investigated and compared to those of without vortex generator.

  • PDF

An Experimental Study of Fouling Effect on the Heat Transfer Around a Tube in Staggered Tube Banks (엇갈림 관군에서 원관 주위의 열전달에 미치는 파울링 영향에 관한 실험적 연구)

  • Kim, Min-Su;Baek, Byeong-Jun;Park, Bok-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1478-1485
    • /
    • 2000
  • An experimental study has been performed to investigated the forced convection heat transfer characteristics of 6 circular cylinders in staggered arrangement in a cross flow of air. The water scale deposited on condenser wall of power plant was used to investigate the effect of roughness of scaled surfaces. The relative roughness*average diameter of scale/cylinder diameter) was in a range of k/d=0.0066, 0.0111, 0.0167, 0.0222 and 0.0278. The cylinder spacings(L/d) varies from 1.5 to 4.0 where L denote the cylinder spacings along and normal to the upstream uniform flow direction. The Reynolds number was varied in a range of 10, 000$\leq$ Re $\leq$ 50,000. The local and mean Nusselt numbers were investigated as a function of scale roughness, the cylinder spacing and Reynolds number. The results are compared with those of clean cylinder and inline tube bank, subsequently the mean fouling resistance over the entire circumference was estimated from those results as a function of scale roughness, the cylinder spacing and Reynolds number.

Design, fabrication, and performance analysis of a twisted hollow fibre membrane module configuration

  • Palmarin, Matthew J.;Young, Stephanie;Lee, Tsun Ho
    • Membrane and Water Treatment
    • /
    • v.6 no.1
    • /
    • pp.15-26
    • /
    • 2015
  • The compact structure and high-quality effluent of membrane bioreactors make them well-suited for decentralized greywater reclamation. However, the occurrence of membrane fouling continues to limit their effectiveness. To address this concern, a unique membrane module configuration was developed for use in a decentralized greywater treatment system. The module featured local aeration directly below a series of inclined membrane bundles, giving the overall module a twisted appearance compared to a module with vertically orientated fibres. The intent of this design was to increase the frequency and intensity of collisions between rising air bubbles and the membrane surface. Material related to the construction of custom-fit modules is rarely communicated. Therefore, detailed design and assembly procedures were provided in this paper. The twisted module was compared to two commercially available modules with diverse specifications in order to assess the relative performance and marketability of the twisted module with respect to existing products. Contaminant removal efficiencies were determined in terms of biochemical oxygen demand, chemical oxygen demand, ammonia, total nitrogen, total phosphorus, and turbidity for each module. Membrane fouling was monitored in terms of permeate flux, transmembrane pressure, and membrane resistance. Following 168 h of operation, the twisted module configuration demonstrated competitive performance, indicating good potential for further development and commercialization.

Performances of submerged membrane photocatalysis reactor during treatment of humic substances

  • Halim, Ronald;Utama, Robert;Cox, Shane;Le-Clech, Pierre
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.283-296
    • /
    • 2010
  • During the disinfection of potable water, humic substances present in the solution react with chlorine to form potential carcinogenic compounds. This study evaluates the feasibility of using a submerged membrane photocatalysis reactor (SMPR) process for treatment of humic substances through the characterization of both organic removal efficiency and membrane hydraulic performance. A simple SMPR was operated and led to the removal of up to 83% of the polluting humic matters. Temporal rates of organic removal and membrane fouling were found to decrease with filtration time. Using tighter membrane in the hybrid process resulted in not only higher organic removal, but also more significant membrane fouling. Under the experimental conditions tested, optimum $TiO_2$ concentration for humic removal was found to be 0.6 g/L, and increasing initial pollutant concentration expectedly resulted in a more substantial membrane fouling. The importance of the influent nature and pollutant characteristics in this type of treatment was also assessed as various water sources were tested (model humic acid solution vs. local water containing natural organic matters). Results from this study revealed the promising nature of the SMPR process as an alternative technique for organic removal in the existing water treatment system.

Experimental Study on the Removal of Biofouling from Specimens of Small Ship Constructions Using Water Jet (물 제트를 이용한 소형선박제작 시편의 선체부착생물 제거에 관한 실험적 연구)

  • Seo, Daewon;Oh, Jungkeun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1078-1085
    • /
    • 2022
  • Fouling organisms attached to a ship not only greatly increase the resistance of the ship as they grow on the hull but also cause disturbances in local marine ecosystems as they move with the ship. Accordingly, the International Maritime Organization has started discussing the removal of biofouling and evaluation of cleaning performance to prevent the migration of hull-fouling species. In this study, specimens of FRP(Fiber Reinforced Plastic), HDPE(High Density Polyethylene), and CFRP(Carbon Fiber Reinforced Plastic) materials used for small ship construction were cured in Gyeokpo Port (Jeonlakbuk-do) for about 80 days. Then, attached organism removal experiments were performed using a water jet nozzle. The results show that seaweeds, such as laver, were removed when the distance between the nozzle and the specimen was 1.8 cm and the pressure was 100 bar. Furthermore, it was confirmed that the cleaning of barnacles was possible only when the pressure was 200 bar or more.

The DISNY facility for sub-cooled flow boiling performance analysis of CRUD deposited zirconium alloy cladding under pressurized water reactor condition: Design, construction, and operation

  • Ji Yong Kim;Yunju Lee;Ji Hyun Kim;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3164-3182
    • /
    • 2023
  • The CRUD on the fuel cladding under the pressurized water reactor (PWR) operating condition causes several issues. The CRUD can act as thermal resistance and increases the local cladding temperature which accelerate the corrosion process. The hideout of boron inside the CRUD results in axial offset anomaly and reduces the plant's shutdown margin. Recently, there are efforts to revise the acceptance criteria of emergency core cooling systems (ECCS), and additionally require the modeling of the thermal resistance effect of the CRUD during the performance analysis. There is an urgent need for the evaluation of the effect of the CRUD deposition on the cladding heat transfer under PWR operating conditions, but the experimental database is very limited. The experimental facility called DISNY was designed and constructed to analyze the CRUD-related multi-physical phenomena, and the performance analysis of the constructed DISNY facility was conducted. The thermal-hydraulic and water chemistry conditions to simulate the CRUD growth under PWR operating conditions were established. The design characteristics and feasibility of the DISNY facility were validated by the MARS-KS code analysis and separate performance tests. In the current study, detailed design features, design validation results, and future utilization plans of the proposed DISNY facility are presented.