• Title/Summary/Keyword: Local emissions

Search Result 257, Processing Time 0.031 seconds

A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials (단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구)

  • Jung, Young In;Choi, Sang Min
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

Difference in Chemical Composition of PM2.5 and Investigation of its Causing Factors between 2013 and 2015 in Air Pollution Intensive Monitoring Stations (대기오염집중측정소별 2013~2015년 사이의 PM2.5 화학적 특성 차이 및 유발인자 조사)

  • Yu, Geun Hye;Park, Seung Shik;Ghim, Young Sung;Shin, Hye Jung;Lim, Cheol Soo;Ban, Soo Jin;Yu, Jeong Ah;Kang, Hyun Jung;Seo, Young Kyo;Kang, Kyeong Sik;Jo, Mi Ra;Jung, Sun A;Lee, Min Hee;Hwang, Tae Kyung;Kang, Byung Chul;Kim, Hyo Sun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.16-37
    • /
    • 2018
  • In this study, difference in chemical composition of $PM_{2.5}$ observed between the year 2013 and 2015 at six air quality intensive monitoring stations (Bangryenogdo (BR), Seoul (SL), Daejeon (DJ), Gwangju (GJ), Ulsan (US), and Jeju (JJ)) was investigated and the possible factors causing their difference were also discussed. $PM_{2.5}$, organic and elemental carbon (OC and EC), and water-soluble ionic species concentrations were observed on a hourly basis in the six stations. The difference in chemical composition by regions was examined based on emissions of gaseous criteria pollutants (CO, $SO_2$, and $NO_2$), meteorological parameters (wind speed, temperature, and relative humidity), and origins and transport pathways of air masses. For the years 2013 and 2014, annual average $PM_{2.5}$ was in the order of SL ($${\sim_=}DJ$$)>GJ>BR>US>JJ, but the highest concentration in 2015 was found at DJ, following by GJ ($${\sim_=}SJ$$)>BR>US>JJ. Similar patterns were found in $SO{_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$. Lower $PM_{2.5}$ at SL than at DJ and GJ was resulted from low concentrations of secondary ionic species. Annual average concentrations of OC and EC by regions had no big difference among the years, but their patterns were distinct from the $PM_{2.5}$, $SO{_4}^{2-}$, $NO_3{^-}$, and $NH_4{^+}$ concentrations by regions. 4-day air mass backward trajectory calculations indicated that in the event of daily average $PM_{2.5}$ exceeding the monthly average values, >70% of the air masses reaching the all stations were coming from northeastern Chinese polluted regions, indicating the long-range transportation (LTP) was an important contributor to $PM_{2.5}$ and its chemical composition at the stations. Lower concentrations of secondary ionic species and $PM_{2.5}$ at SL in 2015 than those at DJ and GJ sites were due to the decrease in impact by LTP from polluted Chinese regions, rather than the difference in local emissions of criteria gas pollutants ($SO_2$, $NO_2$, and $NH_3$) among the SL, DJ, and GJ sites. The difference in annual average $SO{_4}^{2-}$ by regions was resulted from combination of the difference in local $SO_2$ emissions and chemical conversion of $SO_2$ to $SO{_4}^{2-}$, and LTP from China. However, the $SO{_4}^{2-}$ at the sites were more influenced by LTP than the formation by chemical transformation of locally emitted $SO_2$. The $NO_3{^-}$ increase was closely associated with the increase in local emissions of nitrogen oxides at four urban sites except for the BR and JJ, as well as the LTP with a small contribution. Among the meterological parameters (wind speed, temperature, and relative humidity), the ambient temperature was most important factor to control the variation of $PM_{2.5}$ and its major chemical components concentrations. In other words, as the average temperature increases, the $PM_{2.5}$, OC, EC, and $NO_3{^-}$ concentrations showed a decreasing tendency, especially with a prominent feature in $NO_3{^-}$. Results from a case study that examined the $PM_{2.5}$ and its major chemical data observed between February 19 and March 2, 2014 at the all stations suggest that ambient $SO{_4}^{2-}$ and $NO_3{^-}$ concentrations are not necessarily proportional to the concentrations of their precursor emissions because the rates at which they form and their gas/particle partitioning may be controlled by factors (e.g., long range transportation) other than the concentration of the precursor gases.

Effect of exhaust gas dilution rate on formation of flameless combustion using liquid fuel (액체연료 무화염형성에 미치는 배기가스희석율의 영향)

  • Cha, Chun Loon;Lee, Ho Yeon;Hwang, Sang Soon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.301-303
    • /
    • 2014
  • Flameless combustion, well known as MILD (Moderate Intensity Low oxygen Dilution) combustion or CDC(Colorless Distributed Combustion), is considered as one of the promising technology for achieving low NOx and CO emissions with improving thermal efficiency of combustion system. In this paper, the effects of exhaust gas dilution rate on formation of flameless combustion of liquid fuel were analyzed using three-dimensional numerical simulations for application of gas turbine combustor with high power density. Results show that the local high temperature region was decreased and flame temperature was spatially uniformly distributed due to higher dilution rate of burnt gas as similar pattern of gas phase flameless combustion. But the evaporation and mixing process of liquid fuel are found to be another important factors for formation of flameless combustion.

  • PDF

Estimating the Economic Value of Function for Public Benefits on Practice of Organic Farming - Using Choice Experiments (유기농업의 공익기능에 대한 경제적 가치 평가 -실험선택법을 적용하여-)

  • Yoo, Jin-Chae;Kong, Ki-Seo;Yeo, Sun-Sik;Seo, Myung-Chul
    • Korean Journal of Organic Agriculture
    • /
    • v.18 no.3
    • /
    • pp.291-313
    • /
    • 2010
  • The objective of this paper is to apply choice experiment methods to estimate non-market value of organic farming and its policy implication. A preliminary survey shows that the attributes of organic farming are reduce environmental pollution, bio-diversity improvements, cultural diversity improvements and maintain local community, reduce green-house gas emissions, energy saving, landscape improvements and tax for organic farming improvement policy. Questionnaire was eight different choice sets presented to each respondent. Implicit values of the attributive levels of organic farming have been calculated into tax money costs per house. This paper compared the six feasible scenarios in terms of willingness to pay per year. This study is expected to contribute to government's organic farming policies and quantitative information related to practice of organic farming.

Modeling of SO$_2$ Emissions from Yatagan Power Plant

  • Im, Ulas;Yenigun, Orhan
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.69-72
    • /
    • 2003
  • The meteorological model, CALMET, and its plume dispersion model, CALPUFF, were used in order to simulate the dispersion of $SO_2$ emitted from Yatagan Power Plant and its effect on Yatagan district in the episodic event on December 2 and 3, 2000. It is found that south westerly and light winds and the nighttime surface inversion layers lead to accumulation of pollutants over Yatagan district. The results are compared with the measurements done by Local Environmental Authorities of Mu la. The simulation results indicate that the maximum ground level concentrations were found northeast from the source, which agrees with experimental measurement. On the other hand, the magnitude of results obtained with the model shows some differences compared with experimental measurements.

  • PDF

External cost Forecasting of Virtual Point Source in Suwon Area Using Impact Pathway Analysis - A Comparison of Suwon to Paris - (영향경로해석을 이용한 수원시 가상 점오염원의 외부비용 예측 - 수원시와 파리시 비교분석을 중심으로 -)

  • Jeong, Sang Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.291-303
    • /
    • 2005
  • Impact pathway analysis(IPA) is a bottom-up approach to estimates health and environmental risks from emissions of classical pollutants (eg. $PM_{10}$, $SO_2$, $NO_x$ and CO). The model starts from the emission rates of facility, calculates the yearly mean concentrations of pollutants at the ground level using atmospheric dispersion models. After this, proper epidemiological exposure-response functions are applied to determine the impact on the receptors. Finally the methodology can monetise the calculated physical impact on the basis of selected economic evaluation. The aim of this study is to evaluate an external cost of virtual point source in Suwon area using IPA. The results shows minor modification of local input data can make it possible to apply the model to Suwon area.

Structural optimization of stiffener layout for stiffened plate using hybrid GA

  • Putra, Gerry Liston;Kitamura, Mitsuru;Takezawa, Akihiro
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.809-818
    • /
    • 2019
  • The current trend in shipyard industry is to reduce the weight of ships to support the reduction of CO2 emissions. In this study, the stiffened plate was optimized that is used for building most of the ship-structure. Further, this study proposed the hybrid Genetic Algorithm (GA) technique, which combines a genetic algorithm and subsequent optimization methods. The design variables included the number and type of stiffeners, stiffener spacing, and plate thickness. The number and type of stiffeners are discrete design variables that were optimized using the genetic algorithm. The stiffener spacing and plate thickness are continuous design variables that were determined by subsequent optimization. The plate deformation was classified into global and local displacement, resulting in accurate estimations of the maximum displacement. The optimization result showed that the proposed hybrid GA is effective for obtaining optimal solutions, for all the design variables.

The Novel Configuration for Building Energy System Including Build ins Microgrid (빌딩 마이크로그리드가 포함된 새로운 빌딩에너지 시스템 구축방향에 관한 연구)

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.235-240
    • /
    • 2008
  • The recent development of efficient thermal prime movers for distributed generation id changing the focus of the production of electricity from large centralized power plants to local generation units scattered over the territory. The scientific communality is addressing the analysis and planning of the distributed energy resources(der) with wide spread approaches, taking into account technical, environmental, economical and social issues. The coupling of cogeneration system to absorption/electric chillers or heat pumps as well as the interactions with renewable sources, allow for setting up multi-generation systems for building cooling heating and power(BCHP) systems of different energy vectors such as electricity, heat(at different enthalpy levels), cooling power, hydrogen, various chemical substances and so forth. Adoption of the composite multi-generation systems may lead to significant benefits in term of higher efficiency, reduced $CO_2$ emissions and enhanced economy. This paper outlines the main aspects of the BCHP system framework, illistrating its characteristics and summarizing the relevant distributed multi-generation structures.

  • PDF

Research Method and Prediction Model of PM2.5 in Cities

  • Yang, ZhenYu;Xia, Sai;Jin, Jie
    • Journal of Urban Science
    • /
    • v.8 no.2
    • /
    • pp.25-28
    • /
    • 2019
  • Hefei has suffered from heavy air pollution, especially car exhaust and industry emissions. The smoke contains PM2.5 and PM10. These smoke will enter people's bodies and have a bad impact on the human body. This review is about PM2.5. This review covers the sources and hazards of PM2.5. It introduces the use of modelling methods to analyze PM2.5 pollution in various places and proposes treatment measures. These cities were heavily polluted by PM2.5, and after the local government's management and renovation, there has been a significant improvement. However, there are still many shortcomings in the process of pollution improvement. This review combines the means used in the process of pollution prevention and control in Handan City, Beijing. Hefei now suffers from some of the same pollution as these cities did in the past.

Simultaneous optical ignition and spectroscopy of a two-phase spray flame for feedback control System (이상상태 분무 화염에서의 레이저 점화 및 분광 측정을 통한 피드백 제어 연구)

  • Lee, Seok Hwan;Kim, Hyunwoo;Do, Hyungrok;Yoh, Jack J.
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.215-218
    • /
    • 2015
  • Simultaneous laser ignition and spectroscopy is a scheme that enables rapid determination of the local equivalence ratio and condensed fuel concentration during a reaction in a two phase spray flame. We have conducted quantitative analysis of the LIBS signals according to the equivalence ratio, droplet size, droplet number density and droplet concentration as a part of novel feedback control strategy proposed for flame ignition and stabilization with simultaneous in situ combustion flow diagnostics. This is a desirable scheme since such real time information onboard an engine for instance can be constantly monitored and fed back to the control loop to enhance the mixing process and minimize emissions of unwanted species and potential combustion instability.

  • PDF