• Title/Summary/Keyword: Local cooling

Search Result 345, Processing Time 0.029 seconds

Effectiveness of Cooling Vest in Hot Environment (더운환경에서의 냉각조끼의 착용효과에 관한 연구)

  • 최정화;황경숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.1
    • /
    • pp.83-90
    • /
    • 2001
  • Cooling garments are being considered for reducing heat strain in hot environment. We evaluated the effectiveness of ice gel-based cooling vest in hot environment both resting and exercising. Four male subjects were exposed to heat(4$0^{\circ}C$, 50%RH) with vest or without it. The results were as follows; In case of the trial wearing ice gel-based cooling vest, total body weight loss, and local sweat volume were less than those without it. Mean skin temperature, rectal temperature, pulse, energy expenditure, temperature of inside clothes, and humidity of inside also were lower than those without cooling vest. By subjective thermal sensation, subjective humidity sensation, and thermal comfort sensation, it was proved that non-wearing vest decreased comfort than wearing that. These results suggested that wearing ice gel-based cooling vest reduced human heat strain in hot environment both resting and exercising.

  • PDF

Numerical Study on the Thermal Characteristics of the Various Cooling Methods in Electronic Equipment

  • Son, Young-Seok;Shin, Jee-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.46-55
    • /
    • 2004
  • Thermal characteristics of the various cooling methods in electronic equipment are studied numerically. A common chip cooling system is modeled as a parallel channel with protruding heat sources. A two-dimensional model has been developed for the numerical analysis of compressible. viscous. laminar flow. and conjugate heat transfer between parallel plates with uniform block heat sources. The finite volume method is used to solve this problem. The assembly consists of two channels formed by two covers and one printed circuit board that is assumed to have three uniform heat source blocks. Various cooling methods are considered to find out the efficient cooling method in a given geometry and heat sources. The velocity and the temperature fields. the local temperature distribution along the surface of blocks. and the maximum temperature in each block are obtained. The results are compared to examine the thermal characteristics of the different cooling methods both quantitatively and qualitatively.

Effects of radiation-modulated cooling on the momentum transfer from stellar feedback

  • Na, Chongsam;Kimm, Taysun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.70.2-70.2
    • /
    • 2019
  • Strong radiation fields can change the ionization state of metals and hence cooling rates. In order to understand their effects on the momentum transfer from radiation and supernova feedback, we perform a suite of radiation-hydrodynamic simulations with radiation-modulated metal cooling. For this purpose, we pre-tabulate the metal cooling rates for a variety of spectral shapes and flux levels with the spectral synthesis code, Cloudy, and accurately determine the rates based on the local radiation field strength. We find that the inclusion of the radiation-modulated metal cooling decreases the total radial momentum produced by photo-ionization heating by a factor of ~3 due to enhanced cooling at temperature T~10^3-4 K. The amount of momentum transferred from the subsequent SN explosions, however, turns out to be little affected by radiation, as the main cooling agents at T~10^5-6 K are only destroyed by soft X-ray radiation which is generally weak. We further discuss the total momentum budget in various conditions.

  • PDF

A Local Softening Method for Reducing Die Load and Increasing Service Life in Trimming of Hot Stamped Part (핫스템핑 부품의 전단가공에서 전단 하중의 감소 및 트리밍 금형 수명 향상을 위한 국부 연화 방법)

  • Choi, H.S.;Lim, W.S.;Kang, C.G.;Kim, B.M.
    • Transactions of Materials Processing
    • /
    • v.20 no.6
    • /
    • pp.427-431
    • /
    • 2011
  • In general, hot stamped component is trimmed by costly and time consuming laser cutting when the material strength is over 1,500MPa. The aim of this work was to demonstrate that the trimming die life is improved and the trimming load is decreased by lowering the strength of the region to be trimmed. The model employed in this study was a hat shape, similar to the cross section of many hot stamped products. FE-analysis of hot stamping process was performed to evaluate the effect of tool shape on cooling rate at the area to be trimmed. The best tool shape was thus identified, which created slower cooling and lower hardness at the region to be trimmed. The wear at the cutting tool edge was also reduced.

Design of EPICS based Control System for RCCS Cooling Water System in PEFP DTL (양성자 가속장치 냉각계통의 제어시스템의 EPICS 구현에 대한 연구)

  • Yoon, J.C.;Kim, K.R.;Kim, H.S.;Kwon, S.J.;Kim, Hui-Seop;Hwang, W.H.;Park, J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1599-1600
    • /
    • 2007
  • The DTL water skid cooling system and Resonant Control Cooling Systems (RCCS) will employ a control system that can be operated by a local, programmable logic controller (PLC), interfaced through a touch screen interface, mobile alarm SMS server system, or it can be operated through the PEFP global control system network. The RCCS is implemented using Experimental Physics and Control System (EPICS) based hardware and software and is integrated with other networked PEFP EPICS systems. This presentation discusses the features of the local control system.

  • PDF

Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region (희박 분무영역에서의 분무냉각 막 비등 열전달에 관한 연구)

  • Kim Yeung Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.2 s.233
    • /
    • pp.279-286
    • /
    • 2005
  • This study presents experimental results on the heat transfer coefficients in the film boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distributions of a two dimensional dilute spray impinging on a hot plate were experimentally investigated. A stainless steel block was cooled down from intial temperature of about $800^{\circ}C$ by twin fluid (air-water) flat spray. It was found from the experimental results that the heat transfer area was classified into the stagnation region and wall-flow region. In the stagnation region, the experimental data of local heat transfer coefficient was closely correlated with the local droplet-flow-rate supplied from the spray nozzle directly. Thus, the local heat transfer coefficients are in good agreement with the predicted values from the correlations proposed by our previous study. In wall-flow region, however, remarkable differences are observed between experimental data and predicted values because the number of rebound droplets increase with increasing the distance from the stagnation point.

Study on Film Boiling Heat Transfer of Spray Cooling in Air-Water Full Cone Spray System (물-공기 원추형 분무시스템에 있어서 분무냉각 막비등 열전달에 관한 연구)

  • Kim, Yeung-Chan;Yun, Seung-Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1236-1242
    • /
    • 2006
  • The local heat flux of spray cooling in the film boiling region were experimentally investigated for the spray region of $D_{max}$ = $0.005{\sim}0.03m^3/(m^2s)$. A twin-fluid full cone spray nozzle was employed for the experiment and the distributions of droplet flow rates were obtained for air-water full cone sprays. A stainless steel block was cooled down from initial temperature of about $800^{\circ}C$ by full cone spray. In the region near the stagnation point, it was found that the experimental data are in good agreement with the results predicted from the correlations between the local heat transfer and the local droplet flow rate proposed in the previous report. However, it was found that the experimental data of $D_r$ > $0.01m^3/(m^2s)$ are a little smaller than the results predicted from the correlations.

An Experimental Investigation of Jet Impingement Cooling Using the Vortex Tube (보텍스튜브를 이용한 충돌냉각의 실험적 연구)

  • Shin, Woon-Chul;Kim, Chang-Soo;Bae, Shin-Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.8-15
    • /
    • 2007
  • The jet impingement cooling characteristics are investigated experimentally. The study is motivated by the potential application of local hot spot cooling by means of the vortex tube. The purposes of this research are to examine the effect of the nozzle-block spacing and flow rate. The results of jet through vortex tube is compared with ones of circular Jet. Flow visualization by the smoke-wire technique is also performed to investigate the flow structure. As the nozzle-block spacing is increased and flow rate decreased, the cooling effect of the Jet through the vortex tube decreases mere remarkably than that of the circular jet. So the cooling effect for the jet through the vortex tube is higher than that for the circular jet at $H/D{\leq}3$, $Q{\geq}10m^3/h$.

STUDY ON COOLING PERFORMANCE BY CONVECTIVE HEAT TRANSFER WITH DIFFERENT DISK BRAKE SHAPES (브레이크 디스크 형상에 따른 대류열전달에 의한 방열성능 연구)

  • Park, C.W.;Lee, D.R.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.64-71
    • /
    • 2016
  • This research is to numerically investigate the convective cooling performance in the Disk brake. Research concentrates on the heat transfer coefficient and cooling performance which are selected with cooling local locations. Cooling performance of the Hole disk has been compared by Ventilated Disk. According to the results of heat transfer on the disk brake, activated velocity distributions more appear in the Hole disk. This is due to the fact that a number of hole units have exactly 120 on the surface of the hole disk. Therefore, velocity distributions of hole disk brake is better activated than Ventilated disk. According to the calculations of Nusselt number between surface and atmosphere in the interested cooling area, average value of cooling effect has been increased 13.5% by the hole disk at driving of speed 65 km/h situation and grown 18% by the hole disk at driving speed of 100 km/h. Due to the flow of air through the hole route, cooling performance of the hole disk was very excellent. In addition, cooling effect on edge of the bottom is better than the vicinity of center.