• Title/Summary/Keyword: Local Solution

Search Result 1,347, Processing Time 0.032 seconds

Automated static condensation method for local analysis of large finite element models

  • Boo, Seung-Hwan;Oh, Min-Han
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.807-816
    • /
    • 2017
  • In this paper, we introduce an efficient new model reduction method, named the automated static condensation method, which is developed for the local analysis of large finite element models. The algebraic multilevel substructuring procedure is modified appropriately, and then applied to the original static condensation method. The retained substructure, which is the local finite element model to be analyzed, is defined, and then the remaining part of the global model is automatically partitioned into many omitted substructures in an algebraic perspective. For an efficient condensation procedure, a substructural tree diagram and substructural sets are established. Using these, the omitted substructures are sequentially condensed into the retained substructure to construct the reduced model. Using several large practical engineering problems, the performance of the proposed method is demonstrated in terms of its solution accuracy and computational efficiency, compared to the original static condensation method and the superelement technique.

Local Tax Legislative Power for Fiscal Decentralization Reinforcement (지방재정분권강화를 위한 지방세 입법권)

  • Kim, Dong-Bok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.537-542
    • /
    • 2009
  • The Question is to expend Non-Provide Taxes(so on Local Income Tax and Local Consumption Tax). Can we legislate Non-Provide Taxes and levy them to a taxpayer? This Paper is to study a Scheme of Solution for Expansion of Fiscal Decentralization and search Laws and Ordinance, Theories and Case Law of the Major states. Therefore This Study is to aim for expanding at Legislation Power of Local Tax.

  • PDF

Bypass, homotopy path and local iteration to compute the stability point

  • Fujii, Fumio;Okazawa, Shigenobu
    • Structural Engineering and Mechanics
    • /
    • v.5 no.5
    • /
    • pp.577-586
    • /
    • 1997
  • In nonlinear finite element stability analysis of structures, the foremost necessary procedure is the computation to precisely locate a singular equilibrium point, at which the instability occurs. The present study describes global and local procedures for the computation of stability points including bifurcation points and limit points. The starting point, at which the procedure will be initiated, may be close to or arbitrarily far away from the target point. It may also be an equilibrium point or non-equilibrium point. Apart from the usual equilibrium path, bypass and homotopy path are proposed as the global path to the stability point. A local iterative method is necessary, when it is inspected that the computed path point is sufficiently close to the stability point.

Local Irritation of DA-125 (DA-125의 국소자극성)

  • 안병옥;백남기;이순복;김원배;양중익;김부영;김대병;이종권
    • Biomolecules & Therapeutics
    • /
    • v.1 no.1
    • /
    • pp.20-25
    • /
    • 1993
  • DA-125, a new anthracycline derivative, shows significant anticancer activities. We conducted a study to examine the local irritating effect of DA-125 using mice and rabbits. In the skin test in mice, intradermal injection of 0.4 mg of DA-125, compared to a dosage of 0.2 mg of adriamycin, had weak irritating potentials to induce skin ulceration and erythematous induration. A dosage of 0.6 mg of DA-125 produced similar degree of lesions in perivascular irritation model to that of 0.2 mg of adriamycin, but the healing time was shorter in the case of mice treated with DA-125. In ocular irritation study in rabbit, the highest M.O.I.(mean ocular irritation index) of 0.5% DA-125 solution was 0.67, therefore DA-125 could be considered as a practically non-irritating anticancer agent. These results suggest that substitution of DA-125 for Adriamycin would reduces the possibility of outbreaks of local irritation and the severity of the lesions.

  • PDF

Local Coordinative Reactive Power Control Method to Manage Voltage/Momentary Reactive Reserve (전압 및 순동무효예비력 확보를 위한 지역 변전소에서의 무효전력제어장치 협조방식 연구)

  • Lee, Geun-Joon;Yoon, Jong-Soo;Jang, Byung-Hoon;Jung, Sung-Won;Yoon, Sun-Ho;Lee, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.115-116
    • /
    • 2008
  • This paper discusses local reactive power control method of substation which has FACTS controller(STATCOM) and other reactive power controllers. Not only The relation between entral control and local control method was discussed, but also local STATCOM control methd was done. With this results, revised coordinative control method which can implement system voltage sensitivity characteristics of each control devices. Also, this method can give proper solution for system status which requires momentary reactive reserve. This method is expected to be applied to control multiple substation reactive power devices which is combined with SCADA system.

  • PDF

Analysis of Spherical Air Membrane Dome Structures with Local Loadings (공기막 돔의 국부 하중 해석)

  • 이광순;박정현;홍기섭;홍영균
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.325-332
    • /
    • 1998
  • The use of air-supported membrane has considerable attention in recent years. There are, however, a number of problems in the behavior of these structures that have not been fully investigated. For example, the problem of local loafing on such membranes has not been analyzed yet. The paper presents an analysis of internal and external potential energy of a spherical air-supported membrane with vertical longitudinal axis, subjected to local loadings. An internal pressure value of the applied load is established at which tile potential of these structures change positive. During such change the loading portion of the membrane comes into work beyond stable state. The mathematical method is used throughout the paper in obtaining solution. For the mathematical modeling, two assumption are used. One is the theta's elimination and the other is the infinite condition. The paper is illustrating the examples of spherical air membrane dome subjected to local load.

  • PDF

Bus Reconfiguration Strategy Based on Local Minimum Tree Search for the Event Processing of Automated Distribution Substations

  • Ko Yun-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.177-185
    • /
    • 2005
  • This paper proposes an expert system that can enhance the accuracy of real-time bus reconfiguration strategy by adopting the local minimum tree search method and that can minimize the spreading effect of the fault by considering the operating condition when a main transformer fault occurs in an automated substation. The local minimum tree search method is used to expand the best-first search method. This method has the advantage that it can improve the solution performance within the limits of the real-time condition. The inference strategy proposed expert system consists of two stages. The first stage determines the switching candidate set by searching possible switching candidates starting from the main transformer or busbar related to the event. The second stage determines the rational real-time bus reconfiguration strategy based on heuristic rules from the obtained switching candidate set. Also, this paper proposes generalized distribution substation modeling using graph theory, and a substation database based on the study results is designed.

Mobile Robot Path Planner for Environment Exploration (효율적 환경탐사를 위한 이동로봇 경로 계획기)

  • Bae, Jung-Yun;Lee, Soo-Yong;Lee, Beom-Hee
    • The Journal of Korea Robotics Society
    • /
    • v.1 no.1
    • /
    • pp.9-16
    • /
    • 2006
  • The Mobile robots are increasingly being used to perform tasks in unknown environments. The potential of robots to undertake such tasks lies in their ability to intelligently and efficiently search in an environment. An algorithm has been developed for robots which explore the environment to measure the physical properties (dust in this paper). While the robot is moving, it measures the amount of dust and registers the value in the corresponding grid cell. The robot moves from local maximum to local minimum, then to another local maximum, and repeats. To reach the local maximum or minimum, simple gradient following is used. Robust estimation of the gradient using perturbation/correlation, which is very effective when analytical solution is not available, is described. By introducing the probability of each grid cell, and considering the probability distribution, the robot doesn't have to visit all the grid cells in the environment still providing fast and efficient sensing. The extended algorithm to coordinate multiple robots is presented with simulation results.

  • PDF

Local Irritation of DA-3285, Recombinant Human Erythropoietin (유전자재조합법으로 생산한 human erythropoietin(DA-3285)의 국소자극성에 관한 연구)

  • 김옥진;김동환;안병옥;김원배;양중익
    • Toxicological Research
    • /
    • v.12 no.1
    • /
    • pp.101-111
    • /
    • 1996
  • The local irritation studies of DA-3285, recombinant human erytropoietin(rHu-EPO), were carried out in rabbits after the following treatment; single application into the conjunctival sac of the eye, single subcutaneous injection, 7-day repeated subcutaneous injection and 8-day repeated infusion into the ear vein. Also, the local irritancy of DA-3285 leaked around vein was studied in mice by single perivascular injection. The results obtained were as follows. In the result of ocular irritation test, DA-3285 could be considered as a non-irritating material. In single and 7-day repeated subcutaneous irritation test, the irritancy of DA-3285 was not so much different from that of saline. The vascular irritancy of DA3285 by 8-day repeated infusion was negligible and similar to that of saline. And the irritancy of DA3285 by perivascular injection was comparable to that of saline. These results indicate that DA-3285 has no irritating activity when injected through subcutaneous or intravenous route for clinical practice as 3.5% solution.

  • PDF

Simplified dynamic analysis of slender tapered thin-walled towers with additional mass and rigidity

  • Takabatake, Hideo;Mizuki, Akira
    • Structural Engineering and Mechanics
    • /
    • v.3 no.1
    • /
    • pp.61-74
    • /
    • 1995
  • A linearly tapered, doubly symmetric thin-walled closed member, such as power-transmission towers and tourist towers, are often characterized by local variation in mass and/or rigidity, due to additional mass and rigidity. On the preliminary stage of design the closed-form solution is more effective than the finite element method. In order to propose approximate solutions, the discontinuous and local variation in mass and/or rigidity is treated continuously by means of a usable function proposed by Takabatake(1988, 1991, 1993). Thus, a simplified analytical method and approximate solutions for the free and forced transverse vibrations in linear elasticity are demonstrated in general by means of the Galerkin method. The solutions proposed here are examined from the results obtained using the Galerkin method and Wilson-${\theta}$ method and from the results obtained using NASTRAN.