• Title/Summary/Keyword: Loading type

Search Result 1,907, Processing Time 0.032 seconds

Performance assessment of pitch-type wave energy converter in irregular wave conditions on the basis of numerical investigation

  • Poguluri, Sunny Kumar;Kim, Dongeun;Bae, Yoon Hyeok
    • Ocean Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.23-38
    • /
    • 2022
  • In this paper, a pitch-type wave energy converter (WEC-rotor) is investigated in irregular wave conditions for the real sea testing at the west coast of Jeju Island, South Korea. The present research builds on and extends our previous work on regular waves to irregular waves. The hydrodynamic characteristics of the WEC-rotor are assessed by establishing a quasi-two-dimensional numerical wave tank using computational fluid dynamics by solving the Reynolds-averaged Navier-Stokes equation. The numerical solution is validated with physical experiments, and the comparison shows good agreement. Furthermore, the hydrodynamic performance of the WEC-rotor is explored by investigating the effect of the power take-off (PTO) loading torque by one-way and two-way systems, the wave height, the wave period, operational and high sea wave conditions. Irrespective of the sea wave conditions, the absorbed power is quadratic in nature with the one-way and two-way PTO loading systems. The power absorption increases with the wave height, and the increment is rapid and mild in the two-way and one-way PTO loading torques, respectively. The pitch response amplitude operator increases as the wave period increases until the maximum value and then decreases. For a fixed PTO loading, the power and efficiency are higher in the two-way PTO loading system than in the one-way PTO loading system at different wave periods.

Seismic Performance and Design Process of a Ceiling Bracket-Typed Modular Connection (천장 브래킷형 모듈러 시스템의 접합부 내진 성능과 설계 프로세스)

  • Lee, Seungjae;Kang, Changhoon;Park, Jaeseong;Kwak, Euishin;Shon, Sudeok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.27-34
    • /
    • 2020
  • This paper examines the seismic performance and structural design of the ceiling bracket-type modular connection. The bracket-type system reduces the cross-sectional area loss of members and combines units using fitting steel plate, and it has been developed to be fit for medium-story and higher-story buildings. In particular, this study conducted the cyclic loading test for the performance of the C-type and L-type brackets, and compared the results. The test results were also compared with the commercial FEA program. In addition, the structural design process for the bracket-type modular connection was presented. The two connections, proposed as a result of the test results, were all found to secure the seismic performance level of the special moment steel frame. In the case of initial stiffness, the L-type bracket connection was found to be great, but in the case of the maximum moment or fully plastic moment, it was different depending on the loading direction.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

A Study on the Evaluation Methods of the Load-Carrying Capacity of PSC I Type Girder Considering Material Nonlinear (재료 비선형을 고려한 PSC I형 거더교의 내하력평가 기법에 관한 고찰)

  • 심종성;김규선;문도영;주민관
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.187-192
    • /
    • 2003
  • Nowadays, It has adapted both Ultimate Strength Design(USD) and Allowable Stress Design(ASD) Method evaluating load-carrying capacity of PSC I Type Girder Bridge. But it has confused because the each method has brought some different results. This study shows some results of loading test of the PSC I type Girder Bridge and analyzed the structural behavior by FEM analysis considering material nonlinear. Parametric study of effective prestress of post tendon is performed and compared to results of loading test.

  • PDF

Effects of Carbon Black Content and Vulcanization Type on Cure Characteristics and Dynamic Mechanical Property of Styrene-Butadiene Rubber Compound

  • Changwoon Nah;Kim, Wan-Doo;Lee, Seag
    • Macromolecular Research
    • /
    • v.9 no.3
    • /
    • pp.157-163
    • /
    • 2001
  • The influences of carbon black loading and cure type on the cure characteristics including kinetics and dynamic mechanical properties were investigated for a styrene-butadiene rubber (SBR). The rate constants of accelerated sulfur vulcanization reaction at three different temperatures were determined using a cure rheometer, and they were compared with those from the direct measurement of sulfur concentration. The strain softening behavior under dynamic deformation, known as the Payne effect was also discussed depending on the carbon black loading and cure type.

  • PDF

Characteristic of Vertical Stress in Sandy Soil according to Loading Types (재하방법에 따른 사질토 지반의 연직응력 특성)

  • Nam, Hyo-Seok;Lee, Sang-Ho;Kwon, Moo-Nam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.6
    • /
    • pp.83-90
    • /
    • 2009
  • This study was carried out to evaluate the vertical stress properties in sandy soil according to changes of loading type in soil bin compacted three layers. The following conclusions and comparisons have been made based on careful analysis from theoretical and experimental methods. : When sandy soil subjected to cycle-loading, compression of foundation and diffusion of vertical stress increment(${\Delta}{\sigma}_2$) were influenced by magnitude of loading plate. When sandy soil subjected to reloading after removing of pre-loading, the distribution of ${\Delta}{\sigma}_2$ depth at one time of loading plate width was different from its distribution at more deep point cause of load hysteresis, so in case of design of structure, the effect of ${\Delta}{\sigma}_2$ as depth must be considered. The increment of vertical stress will be different as loading condition and foundation depth, the loading condition must be considered in case of structure design.

Damage Behavior of High Strength Reinforced Concrete Columns under Biaxial Lateral Loading (2방향 수평력을 받는 고강도 철근콘크리트 기둥의 파괴거동에 관한연구)

  • 박재영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.411-416
    • /
    • 2000
  • The behavior of high strength reinforced concrete columns subjected to uniaxal reversal loading and biaxial reversal circle path loading was investigated. Four full scale test specimens were tested. All specimens were adopted cantilever type, in order that the critical region is to locate only at the bottom of column. The parameters studied were transverse reinforcement ratio, uniaxial lateral loading and biaxial lateral loading. The damage features of columns by the biaxial loading are different from those of the uniaxial loading, However, the maximum strength and the draft angle at maximum strength were almost the same under uniaxial and biaxial loading. The transverse reinforcement under biaxial loading was very effective for increasing ductility of specimens.

  • PDF

Effect of fiber reinforcing on instantaneous deflection of self-compacting concrete one-way slabs under early-age loading

  • Vakhshouri, Behnam;Nejadi, Shami
    • Structural Engineering and Mechanics
    • /
    • v.67 no.2
    • /
    • pp.155-163
    • /
    • 2018
  • The Early-age construction loading and changing properties of concrete, especially in the multi-story structures can affect the slab deflection, significantly. Based on previously conducted experiment on eight simply-supported one-way slabs this paper investigates the effect of concrete type, fiber type and content, loading value, cracking moment, ultimate moment and applied moment on the instantaneous deflection of Self-Compacting Concrete (SCC) slabs. Two distinct loading levels equal to 30% and 40% of the ultimate capacity of the slab section were applied on the slabs at the age of 14 days. A wide range of the existing models of the effective moment of inertia which are mainly developed for conventional concrete elements, were investigated. Comparison of the experimental deflection values with predictions of the existing models shows considerable differences between the recorded and estimated instantaneous deflection of SCC slabs. Calculated elastic deflection of slabs at the ages of 14 and 28 days were also compared with the experimental deflection of slabs. Based on sensitivity analysis of the effective parameters, a new model is proposed and verified to predict the effective moment of inertia in SCC slabs with and without fiber reinforcing under two different loading levels at the age of 14 days.

An Experimental Study on Interrelation of Influential Parameters on Unbonded Tendon Stress

  • Moon, Jeong-Ho;Lim, Jae-Hyung
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.2E
    • /
    • pp.111-116
    • /
    • 2006
  • The purpose of this study is to investigate the relations between unbonded tendon stress and its influential parameters, i.e. bonded reinforcement ratio, span/depth ratio, and loading type. To this end, the influence of such parameters was examined with twenty eight test results of previous studies. Afterwards, an experimental study was carried out with twenty one test specimens. The investigation of previous and current experiments revealed the followings; (1) The bonded reinforcement ratio and prestressing ratio were proved to be important variables on the unbonded tendon stress. (2) The ratio of span to depth and the type of loading affected the unbonded tendon stress partially although their effects varied with bonded reinforcement ratio. (3) AASHTO LRFD Code and Moon/Lim's design equations predicted the experimental results well with the safety margin.

Forced Resonant Type EMI Dipole Antennas for Frequencies Below 80 MHz

  • Kim, Ki-Chai
    • Journal of electromagnetic engineering and science
    • /
    • v.2 no.1
    • /
    • pp.45-49
    • /
    • 2002
  • This paper presents the basic characteristics of a forced resonant type EMI dipole antennas for frequencies below 80 MHz in which two reactance elements are used for the impedance matching at the fined point. The input impedance of the short dipole less than half-wavelength is controlled by the properly determined loading position and the value of loading reactance. The numerical results show that the small-sized EMI dipole antenna with loller antenna factors for frequencies below 80 MHz can be realized by the reactance loading. In case tole proposed center driven forced resonant type EMI dipole antenna with 0.3 λ length is loaded from the center, the input impedance is matched at feed line with 50 $\Omega$, and hence the antenna has lower factors in the frequency range of 30 to 80 MHz.