• Title/Summary/Keyword: Loading rates

Search Result 580, Processing Time 0.028 seconds

Effects of Rotational Speed and Hydraulic Residence Time on the Ammonia Removal of a Rotating Biological Contactor (RBC) (회전속도와 수리학적 체류시간이 회전원판식(Rotating Biological Contactor;RBC) 여과조의 암모니아 제거에 미치는 영향)

  • 오승용;조재윤;김종만
    • Journal of Aquaculture
    • /
    • v.16 no.3
    • /
    • pp.142-150
    • /
    • 2003
  • Performance of a biological filter, the rotating biological contactor (RBC), is affected by rotational speed and hydraulic residence time (HRT). A RBC with a disc diameter of 62 cm, total surface area of 48.28 $m^2$, volume of 0.34 ㎥, and submergence ratio of 35.4% was tested for the combinations of five rotational speeds (1, 2, 3, 4 & 5 rpm) and three HRT (0.5, 1.0 & 2.0 hr) to find out the maximum removal efficiencies of total ammonia nitrogen (TAN) and nitrite nitrogen of a simulated recirculating aquaculture system. Ammonia loading rate in the system was 25 g of TAN/ ㎥. day. Removal efficiencies were checked when TAN concentrations in the system stabilized for 3 days in each treatment. The concentration of TAN in the system decreased with increasing rotational speed of the RBC up to 4 rpm in all HRT (P<0.05). At the rotational speed of 5 rpm, the efficiencies decreased in all HRT (P<0.05). When the rotational speeds were 1, 2, 3, 4, and 5 rpm, TAN concentrations in the system were 1.35, 0.94, 0.69, 0.66, and 0.76 mg/L at the 0.5 hr HRT, 2.86, 1.18, 0.96, 0.87, and 1.11 mg/L at the 1.0 hr HRT, and 5.30, 2.44, 1.99, 1.77, and 2.01 mg/L at the 2.0 hr HRT, respectively. The TAN removal efficiencies of the RBC at the rotational speeds of 1, 2, 3, 4, and 5 rpm were 32.9, 49.5, 65.1, 72.9, and 62.9% in 0.5 hr HRT,33.1, 74.1, 87.1, 95.8, and 78.5% in 1.0 hr HRT, and 35.5, 76.7, 89.6, 97.0, and 85.5% in 2.0 hr HRT, respectively. TAN removal efficiency of RBC per pass increased with increasing HRT. However, TAN concentration in the system also increased. The best operating condition among the treatments was obtained at the treatment of 0.5 hr HRT and 4 rpm (P<0.05). The TAN concentration was 0.66 mg/L. Concentrations of nitrite nitrogen (NO$_2$$^{[-10]}$ -N) in the system decreased with increasing rotational speed in all HRT while that in the system increased with increasing HRT in all rotational speeds. The ranges of NO$_2$$^{[-10]}$ -N concentrations at HRT of 0.5, 1.0, and 2.0 hr in the system were 0.26~0.32, 0.31~0.56, and 0.43~l.45 mg/L, respectively. The ranges of daily removal rates of TAN in this system were 20.03~23.0 g TAN/㎥ㆍday and those of nitrite nitrogen were 19.65~30.25 g NO$_2$$^{[-10]}$ -N/㎥ㆍday.

Study on The Qptimization of Operating Conditions of batch-type Grain Dryer (평면식 건조기의 적정작업조건 설정에 관한 연구)

  • 박경규;정창주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.4
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

Application of Automatic Stormwater Monitoring System and SWMM Model for Estimation of Urban Pollutant Loading During Storm Events (빗물 자동모니터링장치와 SWMM 모델을 이용한 강우시 도시지역 오염부하량 예측에 관한 연구)

  • Seo, Dongil;Fang, Tiehu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.373-381
    • /
    • 2012
  • An automatic flow and water quality monitoring system was applied to estimate pollutant loads to an urban stream during storm events in DTV (Daeduk Techno Valley), Daejeon, Korea. The monitoring system consists of rainfall gage, ultrasonic water level meter, water quality sensors for DO, temperature, pH, conductivity, turbidity and automatic water sampler for further laboratory analysis. All data are transmitted through on-line system and the monitoring system is designed to be controlled manually in the field and remotely from laboratory computer. Flow rates were verified with field measurements during storm events and showed good agreements. Automatic sampler was used to collect real time samples and analyzed for BOD, COD, TN, TP, SS and other pollutant concentrations in the laboratory. SWMM (Storm Water Management Model) urban watershed model was applied and calibrated using the observed flow and water quality data for the study area. While flow modeling results showed good agreement for all events, water quality modeling results showed variable levels of agreement. These results indicate that current options in the SWMM model to predict pollutant build up and wash-off effects are not sufficient to satisfy modeling of all the rainfall events under study and thus need further modification. This study showed the automatic monitoring system can be used to provide data to assist further refinement of modeling accuracy. This automatic stormwater monitoring and modeling system can be used to develop basin scale water quality management strategies of urban streams in storm events.

Anaerobic Treatment of Leachate Solubilized from Thermal Hydrolysis of Sludge Cake (하수슬러지 케이크 열수분해 탈리액의 혐기성 분해 특성)

  • Kang, Ho;Oh, Baik-Yong;Shin, Kyung-Sook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.10
    • /
    • pp.583-589
    • /
    • 2015
  • This study was performed to evaluate the feasibility of anaerobic pretreatment for the leachate solubilized from thermal hydrolysis of sewage sludge cake. Overall process for the treatment of sludge cake consists of thermal hydrolysis, crystallization of magnesium, ammonium, and phosphate (MAP) for the leachate and anaerobic digestion of supernatant from MAP crystallization. The experimental evidence showed that the optimum ratio of Mg : P for the struvite crystallization of leachate solubilized from thermal hydrolysis of sludge cake was 1.5 to 1.0 as weight basis at the pH of 9.5. With this operational condition, the removal efficiencies of ammonia nitrogen and phosphorous achieved 50% and 97%, respectively. The mesophilic batch test showed that the ultimate biodegradability of the supernatant from MAP crystallization reached 63% at S/I ratio of 0.5. The readily biodegradable fraction of 90% ($S_1$) of the MAP supernatant BVS (Biodegradable Volatile Solids, $S_0$) degraded with $k_1$ of $0.207day^{-1}$ for the initial 17 days where as the rest slowly biodegradable fraction ($S_2$) of 10% of BVS degraded with $k_2$ of $0.02day^{-1}$ for the rest of the operational period. Semi-Continuously Fed and Mixed Reactor (SCFMR) was chosen as one of the best candidates to treat the MAP supernatant because of its total solids content over 6%. Maximum average biogas production rates reached 0.45 v/v-d and TVS removal efficiency of 37~41% was achieved at an hydraulic retention time (HRT) of 20 days and its corresponding organic loading rate (OLR) of 1.43 g VS/L-d.

Estimation of Water Quality Environment in Youngsan and Seumjin River Basins (영산강과 섬진강 유역의 하천 수질환경 평가)

  • 양해근;최희철
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.1
    • /
    • pp.16-31
    • /
    • 2003
  • The water quality environment in Youngsan and Seumjin river basins was investigated based on the concept of the comprehensive Water Quality Index (WQI) and a spacial pollution source. Artificial factors influencing to river water quality have been analyzed. The specific delivery load of Youngsan river basin was found to be 8.34~97.25 kg/day/$\textrm{km}^2$, Gomagwon stream and Gwangju stream showed the relatively high rates as 97.25 kg/day/$\textrm{km}^2$ and 86.06 kg/day/$\textrm{km}^2$, respectively. The specific delivery load in Seumjin river basin was estimated to be 10.98∼19.51 kg/day/$\textrm{km}^2$, Suggesting no Significant Contribution of pollution. WQI of Youngsan watershed revealed 1.36~3.45, whereas Seumjin watershed showed a relatively low value of 0.5~1.47 And it is concluded that the specific delivery load suggested in this study provides the essential core data of the upper limit of pollutants receptor in the watershed area studied. From this study, it is suggested that the integrated environmental management of river basin requires the analysis of pollutants generation rate of the basin and the receptor capability for the self-purification.

A Study of Musculotendinous Problems of Students Majoring in Musical Instruments in Korea (기악과 학생들의 근육과 건 증상에 대한 조사연구)

  • Lee, Eun-Nam;Lee, Eun-Ok;Lee, In-Sook;Park, In-Hyae;Park, Jeong-Sook;Bae, Sung-Cheol;So, Hee-Young
    • Journal of muscle and joint health
    • /
    • v.4 no.1
    • /
    • pp.48-60
    • /
    • 1997
  • This study was undertaken to identify the musculotendinous problems and contributing factors to those problems In students majoring in musical instruments in Korea. The data were collected from March 2, 1996 to March 31, 1996 from 261 music students in various geographical areas. The data were analyzed for descriptive statistics, t-test, chi-square using SPSS $PC^+$ program. The results of this study were as follows : 1. In a questionnaire survey of 261 music students, one hundred twenty five(47.9%) reported having had various musculotendinous symptoms. Twenty seven students among the those who had previous symptoms(21.9%) reported the present symptoms. 2. The experience rates of musculotendinous problems in keyboard players, string players and woodwind players were 50.3%, 48.2%, 33.3% respectively. 3. Most of the students practiced most intensively during their high school years and the musculotendinous symptoms began at the same period. 4. Pain, tenderness and stiffness were the most common symptoms, while paresthesia and motor dysfunction were rare. This indicates that most players had muscle tendinous overuse, while small number had nerve entrapment and motor dysfunction. 5. In past and present symptoms, string players experienced musculotendinous symptoms mainly in both sides of shoulders, lumbar area, left finger, and left wrist, while keyboard players experienced more symptoms in the right wrist, shoulder, fingers than left side. 6. The major contributing factors to the symptoms were weight of instrument, types of instruments, types of daily activities, duration of practice, and playing technique. 7 The most frequent treatment modalities for the symptoms were acupuncture or moxibustion, other alternative therapy such as heat compress and massage. Through this study it was found that the musculotendinous problems might be increased along with their career, due to lack of knowledge about preventive measures and patterns of health behavior seeking alternative modalities rather than professional consultation. Therefore, preventive measures that focus on playing habits such as duration of practice, frequency of rest and position while playing should be developed and taught to the students, their parents, and music educators. Doctors who are interested in this area should attempt to correct the position and posture while playing of the posture. And measures for reduction of loading of instrument weight should also be developed.

  • PDF

Dynamic Deformation Characteristics of Joomunjin Standard Sand Using Cyclic Triaxial Test (반복삼축압축시험을 이용한 주문진 표준사의 동적변형특성 분석)

  • Kim, You-Seong;Ko, Hyoung-Woo;Kim, Jae-Hong;Lee, Jin-Gwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.53-64
    • /
    • 2012
  • In this study, the modified cyclic triaxial tests with Joomunjin standard sand are performed for dynamic deformation characteristics, such as Young's moduli and damping ratio. The cyclic triaxial test is equipped with Local Displacement Transducer (LDT) on the outside of a cell which has a range from $10^{-4}$ to $10^{-1}$ of shear strains, ${\gamma}$ (%), instead of conventional cyclic triaxial test which has linear variable displacement transducer (LVDT) with low precision. With the small strain control, tests were carried out at various loading rates, void ratios, and effective confining pressures. Based on the test results, such as dynamic deformation characteristics, shear modulus, and damping ratio, it is found that the test can measure more range of medium strains (0.02-0.2%) than results obtained from conventional test (resonant column test). For the medium strain range, dynamic deformation characteristics investigated by the cyclic triaxial test are also different from those predicted by nonlinear model in conventional test.

Anti-lipase and Lipolytic Activities of EtOH Extract from Juniperus rigida (노간주나무 에탄올추출물의 지방 흡수 억제 및 지방분해 효능)

  • Lee, Young-Seop;Kim, Jung-Hhyun;Kim, Hyo-Jun;Sohn, Eun-Jin;Kim, Chan-Sik;Jeong, Il-Ha;Jo, Kyu-Hyung;Kim, Joo-Hwan;Kim, Jin-Sook
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.3
    • /
    • pp.216-220
    • /
    • 2010
  • Obesity is an important risk factor that significantly increases mortality and disease rates in the cardiovascular disease, diabetes, and various diseases. So far, the most powerful way to inhibit fat absorption is pancreatic lipase inhibitors. In this study, we investigated the anti-obesity effect of the extract of Juniperus rigida. Juniperus rigida extract (JRE) had a inhibitory effect on pancreatic lipase activity ($IC_{50}$=8.63 ${\mu}g$/ml). In in vivo oil-emulsion loading test, this extract also inhibited the intestinal fat absorption. In addition, we measured inhibitory effects of JRE on activity of phosphodiesterase (PDE) and hormone sensitive lipase (HSL) among the important enzymes associated with lipolysis. JRE strongly inhibited PDE activity ($IC_{50}$=4.56 ${\mu}g$/ml), whereas inhibitory effect on HSL activity was very weak compared with orlistat. As a result, JRE inhibited the absorption of fat by inhibiting the activity of pancreatic lipase and induced lipolysis through inhibition of PDE activity. Therefore, we suggest that Juniperus rigida may be a potential therapeutic agent improving obesity.

Analysis and Service Quality Evaluation on NDSL Website (NDSL 웹사이트 분석 및 서비스 품질평가)

  • Lee, Ju-Hyun;Lee, Eung-Bong;Kim, Hwan-Min
    • Journal of Information Management
    • /
    • v.37 no.4
    • /
    • pp.69-91
    • /
    • 2006
  • The purpose of this study is to improve the effectiveness and quality of web service by analyzing the web service problems and suggesting the solutions through the expert service quality evaluation from the point of view of users and website quality evaluation by measurement tools for a whole NDSL website. In case of website analysis, this study analyzed the website completeness of NDSL site and looked into the problem that users can judge by intuition during their use of the site, and evaluated the searchability and usability for web-based service quality evaluation by centering on the service quality of database quality items. After the results of this analysis, it appeared that there was not a big problem on the use. But after searching, several problems were found on loading rates, website completeness, user sensitiveness, the protection of private information, metadata completeness, website accessability, etc. And as a result of the evaluation of website service quality, it does not show the all satisfactory results in the function of search methods and search result printing, mark list and the items related to full-text in the part of searchability and usability. However, comparing with the results of other information organizations, it shows the similar level of quality.

Estimation of Water Quality Improvement and Reduction of Influent Pollution by Installation of Water Treatment System Filled with Bio-stone Ball (바이오스톤 볼 수처리 시스템에 의한 오염물질 저감 및 저수지의 수질개선효과 산정)

  • Choi, Sunhwa;Kim, Heungseop;Chung, Sewoong
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.5
    • /
    • pp.471-482
    • /
    • 2019
  • Water treatment system filled with Bio-stone Ball (BSB) have been developed for the purification of polluted water in many rivers and lakes. The real-scale plants of BSB water treatment system was constructed for field application test and water purification evaluation in Maewha reservoir. The average water purification efficiencies of BSB watertreatment system shows BOD 70.3% (47.2~97.4%), COD 45.3% (26.1~64.7%), TOC 19.2% (8.5~50.0%), SS 82.8% (73.1~92.7%), Chl-a 80.4% (57.2~91.8%), TN 23.2% (6.4~39.5%), and TP 51.8% (-1.1~80.1%). BSB water treatment system shows very high at 70~80% in the water purification efficiencies of BOD, Chl-a, and SS. The average of pollution loading reduction by installation of BSB treatment system shows 39.2% for COD and 16.8% for TP. The water quality improvement rates (%) of the Maewha reservoir shows TOC 14.5%, COD 14.5%, Chl-a 12.5% and TP 25.1%. The BSB watertreatment system can be applied to many agricultural reservoirs and major rivers to deal with serious water pollution issues.