• Title/Summary/Keyword: Loading area

Search Result 1,257, Processing Time 0.029 seconds

A study on the ice and snow loading condition in Taebaek and Sabuk area in Gangwon province for the construction of KEPCO 765kV transmission lines (한전 765 kV 송전선로 건설을 위한 강원도 태백.사북지역 착빙설 하중조건 검토)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1923-1924
    • /
    • 1996
  • Some part of the route in KEPCO 765kV transmission line being constructed passes through a high mountain area which is 800m above the sea level (Taebaek, Sabuk area in Gangwon province). This area is the top part of Taebaek mountains corresponding to the backbone of korean peninsula and has lots of snow during the winter season because the winter seasonal wind gone up along the mountainside of Taebaek Mts. meets open air of the East sea. KEPCO has experienced 63 faults of T/L between 1968 and 1993 in this area, which is a very serious problem. Especially 154kV Hwang-Ji T/L fault in 1990, 2 was a unprecedented case which needs to be analyzed carefully to take proper measures. After reviewing ice and snow loading conditions and analyzing the fault of Hwang-Ji T/L, we're going to determine the revisement of ice and snow loading condition in this area to increase reliability of 765kV transmission line.

  • PDF

Automated design of optimum longitudinal reinforcement for flexural and axial loading

  • Tomas, Antonio;Alarcon, Antonio
    • Computers and Concrete
    • /
    • v.10 no.2
    • /
    • pp.149-171
    • /
    • 2012
  • The problem of a concrete cross section under flexural and axial loading is indeterminate due to the existence of more unknowns than equations. Among the infinite solutions, it is possible to find the optimum, which is that of minimum reinforcement that satisfies certain design constraints (section ductility, minimum reinforcement area, etc.). This article proposes the automation of the optimum reinforcement calculation under any combination of flexural and axial loading. The procedure has been implemented in a program code that is attached in the Appendix. Conventional-strength or high-strength concrete may be chosen, minimum reinforcement area may be considered (it being possible to choose between the standards ACI 318 or Eurocode 2), and the neutral axis depth may be constrained in order to guarantee a certain sectional ductility. Some numerical examples are presented, drawing comparisons between the results obtained by ACI 318, EC 2 and the conventional method.

Behaviours of steel-fibre-reinforced ULCC slabs subject to concentrated loading

  • Wang, Jun-Yan;Gao, Xiao-Long;Yan, Jia-Bao
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.407-416
    • /
    • 2019
  • Novel steel fibre reinforced ultra-lightweight cement composite (ULCC) with compressive strength of 87.3MPa and density of $1649kg/m^3$ was developed for the flat slabs in civil buildings. This paper investigated structural behaviours of ULCC flat slabs according to a 4-specimen test program under concentrated loading and some reported test results. The investigated governing parameters on the structural behaviours of the ULCC slabs include volume fraction of the steel fibre and the patch loading area. The test results revealed that ULCC flat slabs with and without flexure reinforcement failed in different failure mode, and an increase in volume fraction of the steel fibre and loading area led to an increase in flexural resistance for the ULCC slabs without flexural reinforcement. Based on the experiment results, the analytical models were developed and also validated. The validations showed that the analytical models developed in this paper could predict the ultimate strength of the ULCC flat slabs with and without flexure reinforcement reasonably well.

우리나라 인공호의 부영양화 평가 및 예측에 관한 연구

  • 김재윤
    • Journal of Environmental Science International
    • /
    • v.7 no.4
    • /
    • pp.441-450
    • /
    • 1998
  • The purpose of this study is to evaluate and to predict of eutrophication in lakes by using VollenweiderGECD model and total phosphorus concentration and inflow rate which were measurded in 1993-1996. The results of study was as follows. The annual total phosphorus loading from the watershed was calculated to be 181-195tP /yr at lake Soyang, 591-680tP/yr at lake Chungju, 420-466tP/yr at lake Taechong, 229-278tP/yr at lake Andong, 103-106tP/yr at lake Hapchon, 57-59tP/yr at lake Imha, 194-244tP/yr at lake Namgang, 8386tP /yr at lake Chuam, 99-109tP /yr at lake Somjin. These are discharged, for the most parts, from population and ftshfarm facility. TP loading on the surface area at lake Soyang was 3.0lgP/$m^2$/yr, 2.82gP/$m^2$/yr, 2.84gP/$m^2$/yr, 3. 03gP/$m^2$/yr, at lake Chungju 7.91gP/$m^2$/yr, 6.87gP/$m^2$/yr, 7.38gP/$m^2$/yr, 7.l8gP/$m^2$/yr, at lake Taechong 6.7lgP/$m^2$/yr, 7.25gP/$m^2$/yr, 7.24gP/$m^2$/yr, 6.53gP/$m^2$/yr and TP loading on the surface area of Nakdong river basin, that is, lake Andong, Imha, Hapchon and Namgang were 5.39gP/$m^2$/yr, 4.47gP/$m^2$/yr, 4. 56gP/$m^2$/yr, 4.45gP/$m^2$/yr and 2.20gP/$m^2$/yr, 2.23gP/$m^2$/yr, 2.24gP/$m^2$/yr, 2.l7gP/$m^2$/yr and 4.50gP/$m^2$/ yr, 4.50gP/$m^2$/yr, 4.54gP/$m^2$/yr, 4.43gP/$m^2$/yr and 8.25gP/$m^2$/yr, 8.48gP/$m^2$/yr, 8.48gP/$m^2$/yr, 10. 39gP/$m^2$/yr respectively. Also those of lake Chuam was 2.51gP/$m^2$/yr, 2.61gP/$m^2$/yr, 2.52gP/$m^2$/yr, 2. 54gP/$m^2$/yr and TP loading on the surface area at lake Somjin was analysed 4.09gP/$m^2$/yr, 4.l0gP/$m^2$/yr, 3.98gP/$m^2$/yr,3.73gP/$m^2$/yr. The tropic states of nine lakes can be assessed as eutrophy because phosphorus loading exceeds the critical phosphorus loading by Vollenwelder-GECD model.

  • PDF

Stresses around an underground opening with sharp corners due to non-symmetrical surface load

  • Karinski, Y.S.;Yankelevsky, D.Z.;Antes, M.Y.
    • Structural Engineering and Mechanics
    • /
    • v.31 no.6
    • /
    • pp.679-696
    • /
    • 2009
  • The paper aims at analyzing the stress distribution around an underground opening that is subjected to non-symmetrical surface loading with emphasis on opening shapes with sharp corners and the stress concentrations developed at these locations. The analysis is performed utilizing the BIE method coupled with the Neumann's series. In order to implement this approach, the special recurrent relations for half plane were proven and the modified Shanks transform was incorporated to accelerate the series convergence. To demonstrate the capability of the developed approach, a horseshoe shape opening with sharp corners was investigated and the location and magnitude of the maximum hoop stress was calculated. The dependence of the maximum hoop stress location on the parameters of the surface loading (degree of asymmetry, size of loaded area) and of the opening (the opening height) was studied. It was found that the absolute magnitude of the maximum hoop stress (for all possible surface loading locations) is developed at the roof points when the opening height/width ratio is relatively large or when the pressure loading area is relatively narrow (compared to the roof arch radius), and contrarily, when the opening height/width ratio is relatively small or when the surface pressure is applied to a relatively wide area, the absolute magnitude of the maximum hoop stress is developed at the bottom sharp corner points.

Performance of Upflow Anaerobic Sludge Blanket (UASB) Reactor Depending on Reactor Configuration and Sludge Bed Fluidization (반응조 형태 및 슬러지층 유동화 특성에 따른 Upflow Anaerobic Sludge Blanket (UASB) 반응조의 운전효율)

  • Jeong Byung-Gon
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.179-185
    • /
    • 2006
  • Effect of organic loading rate on UASB performance was evaluated under the renditions of some surface area/reactor volume ratio and different reactor diameter. At the low leading rate of 0.4 kg $COD/m^3{\cdot}d$, reactor performance was not affected by reactor diameter. At the organic loading rate of 6 kg $COD/m^3{\cdot}d$, however, volatile acid accumulation and low COD removal efficiency is observed in reactor having 6.4 cm diameter, while volatile acid is not accumulated at all and high COD removal efficiency is observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor, while sludge bed ran not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of 20 kg $COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

Effects of Sediments on the Growth of Algae at Chusori Area in Daechung Reservoir (대청호 추소리 수역의 퇴적물이 조류 성장에 미치는 영향)

  • Oh, Kyoung-Hee;Kim, Yong-Jun;Cho, Young-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.533-542
    • /
    • 2015
  • In order to investigate the effect of internal loading from sediment on algal blooming at Chusori area in Daechung Reservoir, the amount and contamination level of sediment and the release rate of total phosphorus were analyzed. The sedimentary layer was consisted with two layers, and the average depth of upper and lower ones were 0.35 and 1.44 m, respectively. The fraction of inorganic phosphorus in the sediment was higher than that of organic phosphorus, and the fractions of phosphorus which responsible for internal loading were very high as in the range of 72.7 and 80.2% of inorganic phosphorus. The C/N ratio of sediment taken with core sampler indicated the organic compounds are originated from settled algae from water body. The average release rate of total phosphorus from sediment was $6.74({\pm}0.50)mg/m^2/day$. These results indicated that the internal loading from sediment contributes the excessive algal growth at Churosi area, and the countermeasures to improve the quality of sediments are required to manage algal blooming in Daechung Reservoir.

Fractions of Phosphorus in the Surficial Sediment of Dongjin Sea Area (동진강 해역 표층 퇴적물 중 인의 화학적 형태별 함량)

  • Lee, Hyun-Jeong;Son, Jae-Gwon;Park, Bong-Ju;Cho, Jae-Young
    • Journal of Korean Society of Rural Planning
    • /
    • v.11 no.4 s.29
    • /
    • pp.25-31
    • /
    • 2005
  • The present study was carried out to investigate the P fractions of surfical sediment of Dongjin sea area. Furthermore, potential released loading of adsorbed and non-apatite inorganic phosphorus were investigated in the sediment of Dongjin sea area. The contents of phosphorus fractions of the surficial sediment in Dongjin sea area were adsorbed-P 0.06%, nonapatite inorganic-P 13.02%, apatite-P 60.22%, and residual-P 26.70%. The most abundant fraction was apatite-P, residual-P, nonapatite inorganic-P, and adsorbed-P followed it. Potential released loading of adsorbed and non-apatite inorganic phosphorus surveyed 2.6 and 597ton respectively. These results show that sediment-managing and interception from external pollution are needed for water environmental maintenance of Dongjin sea area.

A Study on the Performance Characteristics of Direct Methanol Fuel Cell with Changing of Catalyst Loading (촉매량 변화에 따른 직접 메탄올 연료전지의 성능 특성에 관한 연구)

  • Seo, Sang-Hern;Lee, Chang-Sik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.6
    • /
    • pp.467-473
    • /
    • 2008
  • This study is to investigate the influence of catalyst loading quantity on the direct methanol fuel cell (DMFC) performance. In this paper, Pt-Ru and Pt-black loading as the catalyst were varied from 1 to $4mg/cm^2$ at the anode and cathode, respectively. The experiment was conducted with single fuel cell consisted of $5cm^2$ effective electrode area, serpentine type flow pattern and Nafion 117 membrane. Also, AC impedance and methanol crossover current were measured to investigate the performance loss precisely. As a result, the performance of fuel cell was significantly increased with the increase of cathode catalyst loading. However, the performance did not increase further above a certain Pt-Ru catalyst loading as the increase of anode catalyst loading.

Effects of Various Loading Periods on the Consolidation Characteristics of Remolded Clay - With Special Reference to Gwangyang Marine Clayey Soil - (하중재하기간이 재성형 점토의 압밀특성에 미치는 영향 - 광양항 해성점토를 중심으로 -)

  • Hong, Jae-Cheol;Kim, Jin-Young;Shim, Jae-Rok;Kang, Kwon-Soo;Kim, Ju-Hyun;Baek, Won-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.2
    • /
    • pp.53-64
    • /
    • 2014
  • This study sets it's face to define effects of the various loading periods in normal consolidation area on clay's compression and long-term consolidation characteristics through a laboratory test using homogeneous remolded clay. Moreover, by carrying out a long-term consolidation test which diversifies initial consolidation applicable to effective overburden loading in the various loading period. This study intended to suggest the method predicting the final settlement on the basis of loading periods by comparing and analyzing compression curve's characteristics according to loading weight of each stage and increase in loading period when carrying out the standard consolidation test. From the test results, the study shows that as of the soft clay's compression characteristics on the basis of various loading periods, preconsolidation load has a tendency to be decreased slightly as the loading period is getting more and more longer at each step after initial consolidation load puts on the remolded clay which is caused by secondary consolidation's increase in the latter part of each phase. And those effects have an weaker influence on compression index in normal consolidation area at the same time as secondary consolidation brought out quasi-overconsolidation and stabilization of clay's structure, have an influence re-compression index is increased in overconsolidation area on the other hand.