Evaluation of Mechanical Properties and FEM Analysis on Thin Foils of Copper (구리 박막의 기계적 물성 평가 및 유한요소 해석)

  • Kim Yun-Jae;An Joong-Hyok;Park Jun-Hyub;Kim Sang-Joo;Kim Young-Jin;Lee Young-Ze
    • Tribology and Lubricants
    • /
    • v.21 no.2
    • /
    • pp.71-76
    • /
    • 2005
  • This paper compares of mechanical tensile properties of 6 kinds of copper foil. The beam lead made with copper foil. Different from other package type such as plastic package, Chip Size Package has a reliability problem in beam lead rather than solder joint in board level. A new tensile loading system was developed using voice-coil actuator. The new tensile loading system has a load cell with maximum capacity of 20 N and a non-contact position measuring system based on the principle of capacitance micrometry with 0.1nm resolution for displacement measurement. Strain was calculated from the measured displacement using FE analysis. The comparison of mechanical properties helps designer of package to choose copper for ensuring reliability of beam lead in early stage of semiconductor development.

Poly(vinyl pyrrolidone) Conjugated Lipid System for the Hydrophobic Drug Delivery

  • Lee, Hye-Yun;Yu, Seol-A;Jeong, Kwan-Ho;Kim, Young-Jin
    • Macromolecular Research
    • /
    • v.15 no.6
    • /
    • pp.547-552
    • /
    • 2007
  • Water soluble polymer, poly(vinyl pyrrolidone) was chosen to conjugate with 1,2-dioleoyl-sn-glycero-3-phosphoethanolamine-N-(succinyl) (N-succinyl DPPE) to make a new drug delivery system. PVP with an amine group (amino-PVP) was polymerized by free radical polymerization. The amine group of amino-PVP was conjugated with the carboxylic group of N-succinyl DPPE. The resultant conjugate could form nanoparticles in the aqueous solution; these nanoparticles were termed a lipid-polymer system. The critical aggregation concentration was measured with pyrene to give a value of $1{\times}10^{-3}g/L$. The particle size of the lipid-polymer system, as measured by DLS, AFM and TEM, was about 70 nm. Lipophilic component in the inner part of the lipid-polymer system could derive the physical interaction with hydrophobic drugs. Griseofulvin was used as a model drug in this study. The loading efficiency and release profile of the drug were measured by HPLC. The loading efficiency was about 54%. The release behavior was sustained for a prolonged time of 12 days. The proposed lipid-polymer system with biodegradable and biocompatible properties has promising potential as a passive-targeting drug delivery carrier because of its small particle size.

A Study on the Removal of Phenol by Hybrid Process coupling adsorption with microfiltration (흡착과 정밀여과의 혼성공정에 의한 페놀 제거에 관한 연구)

  • ;;Fane, A. G.
    • Membrane Journal
    • /
    • v.6 no.2
    • /
    • pp.109-116
    • /
    • 1996
  • This work is a fundamental study for applying hybrid process coupling adsorption with microfiltration to waste-water treatment. Phenol was separated by adsorption on powdered activated carbon, adsorbed phenol with activated carbon was separated by microfiltration. As the particle size in suspension increased, filtration resistance decreased, and effect of particle concentration on resistance was less pronounced. The rate of uptake was greatly dependent on the degree of phenol loading. For a smaller amounts of activated carbon, the change of permeate concentration before break point and phenol loading with time were steeper than in the case of large amounts. Permeate concentration before break point decreased with decreasing particle size, this could be due to the increase of outer surface of particle and film mass transfer coefficient.

  • PDF

Estimation of Optimum Tug Capacity for VLCC and Its Application to VLCC Terminal in Gwang-Yang Harbor

  • In-Yong GONG;Lee, Chang-Min;Chan-Su-YANG;Lee, Han-Jin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.08a
    • /
    • pp.3-13
    • /
    • 2004
  • The total tug capacity needed for berthing/de-berthing operations of a ship may vary depending on the ship type, size, loading conditions, and environmental circumstances. Traditionally, total tug capacity is determined based on the local guidelines of port authorities or on the rule of thumb. However, the social demands for the enhancement of ship safety at harbor and the economical demands for the cost-effectiveness of tug usage makes it necessary for port authorities to develop more reasonable and detailed guidelines on tug usage which takes various conditions into account. In this paper, the method to estimate the optimum tug capacity of VLCC is suggested by considering various ship conditions such as its size, loading conditions, and environmental circumstances such as wind, wave, tidal currents, and geographical characteristics of a terminal. This method is applied to a VLCC terminal located in Gwang-Yang Harbor of Korea and the results are compared with the local guidelines of the harbor, which shows that there may be a room for the amendment of local guidelines on tug usage.

  • PDF

Method and mechanism of dispersing agent free dispersion of short carbon fibers in silicon carbide powder

  • Raunija, Thakur Sudesh Kumar;Mathew, Mariamma;Sharma, Sharad Chandra
    • Carbon letters
    • /
    • v.15 no.3
    • /
    • pp.180-186
    • /
    • 2014
  • This study highlights a novel method and mechanism for the rapid and effective milling of carbon fibers (CFs) in silicon carbide (SiC) powder, and also the dispersion of CFs in SiC powder. The composite powders were prepared by chopping and exfoliation of CFs, and ball milling of CFs and SiC powder in isopropyl alcohol. A wide range of CFs loading, from 10 to 50 vol%, was studied. The milling of CFs and SiC powder was checked by measuring the average particle size of the composite powders. The dispersivity of CFs in SiC powder was checked through scanning electron microscope. The results show that the usage of exfoliated CF tows resulted in a rapid and effective milling of CFs and SiC powder. The results further show an excellent dispersion of CFs in SiC powder for all CFs loading without any dispersing agent.

Impedance Matching of Electrically Small Antenna with Ni-Zn Ferrite Film

  • Lee, Jaejin;Hong, Yang-Ki;Lee, Woncheol;Park, Jihoon
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.428-431
    • /
    • 2013
  • We demonstrate that a partial loading of $Ni_{0.5}Zn_{0.5}Fe_2O_4$ (Ni-Zn ferrite) film remarkably improves impedance matching of electrically small $Ba_3Co_2Fe_{24}O_{41}$ ($Co_2Z$) hexaferrite antenna. A 3 ${\mu}m$ thick Ni-Zn ferrite film was deposited on a silicon wafer by the electrophoresis deposition process and post-annealed at $400^{\circ}C$. The fabricated Ni-Zn ferrite film has saturation magnetization of $268emu/cm^3$ and coercivity of 89 Oe. A partial loading of the Ni-Zn ferrite film on the $Co_2Z$ hexaferrite helical antenna increases antenna return loss to 24.7 dB from 9.0 dB of the $Co_2Z$ antenna. Experimental results show that impedance matching and maximum input power transmission to the antenna without additional matching elements can be realized, while keeping almost the same size as the $Co_2Z$ antenna size.

Nonlocal Formulation for Numerical Analysis of Post-Blast Behavior of RC Columns

  • Li, Zhong-Xian;Zhong, Bo;Shi, Yanchao;Yan, Jia-Bao
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.403-413
    • /
    • 2017
  • Residual axial capacity from numerical analysis was widely used as a critical indicator for damage assessment of reinforced concrete (RC) columns subjected to blast loads. However, the convergence of the numerical result was generally based on the displacement response, which might not necessarily generate the correct post-blast results in case that the strain softening behavior of concrete was considered. In this paper, two widely used concrete models are adopted for post-blast analysis of a RC column under blast loading, while the calculated results show a pathological mesh size dependence even though the displacement response is converged. As a consequence, a nonlocal integral formulation is implemented in a concrete damage model to ensure mesh size independent objectivity of the local and global responses. Two numerical examples, one to a RC column with strain softening response and the other one to a RC column with post-blast response, are conducted by the nonlocal damage model, and the results indicate that both the two cases obtain objective response in the post-peak stage.

Design of a Compact LPDA Antenna using Inverted-L Shaped Dipole Elements (Inverted-L 형태의 다이폴 소자를 이용한 소형 LPDA 안테나 설계)

  • Yeo, Jun-Ho;Lee, Jong-Ig
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.7A
    • /
    • pp.678-682
    • /
    • 2011
  • In this paper, a compact log periodic dipole array (LPDA) antenna operating from 1 to 6 GHz is studied. Inverted-L shaped dipole elements are used to miniaturize the lateral size of an LPDA antenna and the spacing factor is also decreased to reduce the total length of the LPDA antenna. As the top-loading length of the inverted-L shaped dipole elements is increased, the width of the LPDA antenna is decreased but the bandwidth and the gain of the antenna are decreased. The fabricated compact LPDA antenna is printed on FR4 substrate With a dielectric constant of 4.4 and a thickness of 1.6 mm, and its size is reduced to 32% in width and 49% in length compared to a standard LPDA antenna.

Investigation of Aggregate Size Effect on Cracking Behavior in Concrete Fracture Test using Mechanoluminescent Paint (압광 페인트를 이용한 콘크리트 파괴시험시 골재크기가 균열성상에 미치는 영향조사)

  • Lee, Chang Joon;Kim, Wha-Jung;Kim, Ji-Sik;Jeon, Ki-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.93-98
    • /
    • 2012
  • In order to capture the fast crack propagation in an unmanipulated concrete fracture test, we employed mechanoluminascent(ML) material, which emits visible light when stressed, as a crack visualization tool. Three-point bending fracture test setup, a paint type ML material and a high speed camera were used to capture the images of fast moving cracks. The maximum size of coarse aggregates of concrete was used as an experimental parameter. The crack images, loading, and crack mouth opening displacement were successfully recorded as a function of time elapsed. From the test results, several interesting cracking behavior in the unmanipulated fracture test was observed in such that (1) the crack moves fast while the load is slowly decreased after the maximum loading, and (2) the crack in concrete with larger coarse aggregates moves faster than the others.

Wall slip of vaseline in steady shear rheometry

  • Song, Ki-Won;Chang, Gap-Shik;Koo, Ja-Seung
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.2
    • /
    • pp.55-61
    • /
    • 2003
  • The steady shear flow properties of vaseline generally used as a base of the pharmaceutical dosage forms were studied in the consideration of wall slip phenomenon. The purpose of this study was to show that how slip may affect the experimental steady-state flow curves of semisolid ointment bases and to discuss the ways to eliminate (or minimize) wall slip effect in a rotational rheometer. Using both a strain-controlled ARES rheometer and a stress-controlled AR1000 rheometer, the steady shear flow behavior was investigated with various experimental conditions ; the surface roughness, sample preparation, plate diameter, gap size, shearing time, and loading methods were varied. A stress-controlled rheometer was suitable for investigating the flow behavior of semisolid ointment bases which show severe wall slip effects. In the conditions of parallel plates attached with sand paper, treated sample, smaller diameter fixture, larger gap size, shorter shearing time, and normal force control loading method, the wall slip effects could be minimized. A critical shear stress for the onset of slip was extended to above 10,000 dyne/$\textrm{cm}^2$. The wall slip effects could not be perfectly eliminated by any experimental conditions. However, the slip was delayed to higher value of shear stress by selecting proper fixture properties and experimental conditions.