• 제목/요약/키워드: Loading Resistor

검색결과 12건 처리시간 0.024초

초퍼저항 및 de-loading 협조제어를 통한 해상풍력 연계용 HVDC시스템 DC전압 상승 억제 방안 (DC Voltage Build-Up Suppression Scheme of HVDC System for Offshore Wind Farm Connection using Chopper Resistor and de-loading)

  • 이형진;강병욱;김재철
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.750-756
    • /
    • 2017
  • This paper presents a method for DC voltage control of HVDC system connection of offshore wind farms. In the event of fault in AC grid, HVDC system need to meet LVRT regulations. When HVDC system meet LVRT regulation, unbalance is caused between power input and power output for DC link. Therefore, LVRT regulation lead to DC voltage increase of HVDC system. To control the DC voltage increase, the chopper resistor can be suggested. In this paper, DC voltage suppression is proposed using chopper resistor and de-loading. The effectiveness of the chopper resistor was verified using PSCAD/EMTDC.

메탈 필름 저항의 펄스 대전력 시험 (Pulse energy high Power test of metal film resistor)

  • 손윤규;장성덕;권세진;오종석;조무현;이경태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2103-2105
    • /
    • 2005
  • Metal film type of resistor have been tested to invest maximum usable power at the pulsed high voltage and pulsed high current. Experiments were carried out using capacitor charging power supply and dump switch. Pulsed amplitude were varied from 1kV to 25kV. The peak current reached was 1kA. Datasheet are given for the limited pulsed power and energy for metal film type of resistor in nanosecond and microsecond time range. The experimental investigation of the threshold loading of the resistor in the high current and voltage pulsed mode has shown that the process of destruction of resistor has specific features for each mode. The mechanisms of failure and destruction of resistors under action of high-voltage and high-current pulses are discussed.

  • PDF

안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가 (Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality)

  • 이윤희;어성욱
    • 한국물환경학회지
    • /
    • 제29권6호
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.

감광성 폴리머 저항 페이스트 제조와 미세패턴 후막저항의 형성 (Fabrication of Photosensitive Polymer Resistor Paste and Formation of Finely-Patterned Thick Film Resistors)

  • 김동국;박성대;유명재;심성훈;경진범
    • 공업화학
    • /
    • 제20권6호
    • /
    • pp.622-627
    • /
    • 2009
  • 알칼리 수용액에 현상이 가능한 감광성 수지재료와 전도성 카본블랙 필러를 이용하여 포토 패터닝이 가능한 폴리머 후막 저항 페이스트를 제조하고 평가하였다. 감광성 수지로는 인쇄회로기판의 보호층으로 주로 사용되는 photo solder resist(PSR)를 사용하여 자외선에 의한 노광 및 알칼리 수용액에의 현상이 가능하게 하였다. 감광성 폴리머 저항 페이스트를 제작한 후, PCB 테스트 보드를 이용하여 후막저항체의 전기적 특성을 평가하였다. 카본블랙의 첨가량에 따라 시트저항은 감소하였으나, 과량 첨가시에는 현상성에 한계를 나타내었다. 재경화에 따라서 시트저항이 감소하였으며, 카본블랙의 첨가량이 많을수록 그 변화율은 작게 나타났다. 포토공정을 적용하여, 미세 패터닝된 meander형 후막저항체를 제조할 수 있었고, 이 방법을 통하여 적은 면적에도 시트저항의 수십 배에 달하는 큰 저항값을 구현할 수 있었다.

저항 부하된 소형 다이폴을 이용한 3축 등방성 전기장 프로브 설계 (3-Axial Isotropic Electric-Field Probe Design with Resistor-Loaded Short Dipole)

  • 문성원;장병준
    • 한국전자파학회논문지
    • /
    • 제28권3호
    • /
    • pp.246-249
    • /
    • 2017
  • 본 논문에서는 저항 부하를 갖는 소형 다이폴을 이용하여 3축 등방성 전기장 측정 프로브를 설계하였다. 특히, 상용 저항소자와 PCB를 이용함으로써 상용화에 장점이 있다. 설계된 전기장 측정 프로브는 저항 부하로 인한 광대역 특성으로 100 kHz에서 3 GHz까지의 광대역 특성을 갖는다. 제작 결과 광대역에 걸쳐 ${\pm}0.39dB$ 이내의 등방성 특성, 0.1 V/m의 수신감도 특성, 3 dB 이내의 주파수 응답 특성을 얻었다. 특히 250 kHz에서 3 GHz까지의 주파수 응답 특성은 ${\pm}1.4dB$의 우수한 특성을 보여 기존 전기장 프로브에 비해 우수한 특성 개선을 보였다.

종래의 차동증폭기를 사용한 인공위성 배터리 셀 전압 감시 시스템 (Satellite Battery Cell Voltage Monitor System Using a Conventional Differential Amplifier)

  • 구자춘;최재동;최성봉
    • 한국항공우주학회지
    • /
    • 제33권2호
    • /
    • pp.113-118
    • /
    • 2005
  • 본 논문은 한쪽 또는 양쪽의 측정 점들이 종래의 차동증폭기에서 허용되는 전압 범위를 초과할 때 차동전압 측정을 위한 인공위성 배터리 셀 전압 감시 시스템을 제시하였다. 본 시스템은 다수개의 직렬로 연결된 셀들로 구성된 재충전 가능한 인공위성 배터리에서 몇몇의 셀 전압들이 높은 공통모드 전압에서 측정될 때 각 셀 전압 감시를 위해 특히 유용하다.

생물환원전극 미생물연료전지에서 외부저항 및 유입부하에 따른 유기물 및 질소 제거와 전기생산에 미치는 영향 (Effect of the Organic and Nitrogen Removal and Electricity Production on Changing the External Resistor and the Inflow Loading in the Biocathode Microbial Fuel Cell)

  • 김지연;김병군;김홍석;윤주환
    • 한국물환경학회지
    • /
    • 제31권5호
    • /
    • pp.556-562
    • /
    • 2015
  • In order to remove the organic substances and the nitrate-nitrogen contained in wastewater, some researchers have studied the simultaneous removal of organics and nitrogen by using different biocathode microbial fuel cells (MFCs). The operating conditions for removing the contaminants in the MFCs are the external resistances, HRTs, the concentration of the influent wastewater, and other factors. This study aimed to determine the effect of the external resistors and organic loading rates, from the changing HRT, on the removal of the organics and nitrogen and on the production of electric power using the Denitrification Biocathode - Microbial Fuel Cell (DNB-MFC). As regards the results of the study, the removal efficiencies of $SCOD_{Cr}$ did not show any difference, but the nitrate-nitrogen removal efficiencies were increased by decreasing the external resistance. The maximum denitrification rate achieved was $129.2{\pm}13.54g\;NO_3{^-}-N/m^3/d$ in the external resistance $1{\Omega}$, and the maximum power density was $3,279mW/m^3$ in $10{\Omega}$. When the DNB-MFC was operated with increasing influent organic and nitrate loading by reducing the HRTs, the $NO_3{^-}-N$ removal efficiencies were increased linearly, and the maximum nitrate removal rate was $1,586g\;NO^3{^-}-N/m^3/d$ at HRT 0.6 h.

Design of Metamaterial-Inspired Wideband Absorber at X-Band Adopting Trumpet Structures

  • Kim, Beom-Kyu;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • 제14권3호
    • /
    • pp.314-316
    • /
    • 2014
  • This letter presents two types of metamaterial-inspired absorbers adopting resistive trumpet structures at the X band. The unit cell of the first type is composed of a trumpet-shaped resonator loading a chip resistor, a metallic back plane, and a FR4 (${\varepsilon}_r=4.4-j0.02$) substrate between them (single-layer). The absorption rate is 99.5% at 13.3 GHz. The full width at half maximum (FWHM) is 95 % at 11.2 GHz (from 5.9 to 16.5 GHz). The size of unit cell is $5.6{\times}5.6{\times}2.4mm^3$. The second type has been optimized with a $7{\Omega}$/square uniform resistive coating, removing the chip resistors but leading to results comparable to the first type. The proposed absorbers are almost insensitive to polarizations of incident waves due to symmetric geometry.

다이아프램 감지부 구조를 갖는 소형 로드셀의 정격출력 계산에 관한 연구 (Calculation of rated output in diaphragm type miniature load cell)

  • 권영하;강대임;주진원
    • 한국정밀공학회지
    • /
    • 제7권2호
    • /
    • pp.58-64
    • /
    • 1990
  • As the miniature load cells have small inner space and sensing elements of which are thin and very sensitive to manufacturing conditions, it is very difficult to predict the rated outputs and control them by using the compensation resistor. The very useful equation has been derived for calculation of theoretical rated outputs for diaphragm type miniature load cells when commercial diaphragm strain gages are used. Four diaphragm type miniature load cells of which capacities are from 300 N to 1, 000 N and outer diameters are 20 mm and 26.5 mm are manufactured. The differences between calculating results and actural ones are less than 5%. According to numerical analysis the decrease of rated outputs caused to main error is examined in existence of loading button.

  • PDF

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.