• Title/Summary/Keyword: Load switch

Search Result 457, Processing Time 0.039 seconds

A Novel Fault Detection Method of Open-Fault in NPC Inverter System (NPC 인버터의 개방성 고장에 대한 새로운 고장 검출 방법)

  • Lee, Jae-Chul;Kim, Tae-Jin;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.115-122
    • /
    • 2007
  • In this paper, a novel fault detection method for fault tolerant control is proposed when the NPC inverter has a open failure in the switching device. The open fault of switching device is detected by checking the variation of a leg-voltage in the neutral-point-clamped inverter and the two phases control method is used for continuously balance the three phases voltage to the load. It can be achieve the fault tolerant control for improving the reliability of the NPC inverter by the fault detection and reconfiguration. This method has fast detection ability and a simple realization for fault detection, compared with a conventional method. Also, this fast detection ability improved the harmful effects such as DC-link voltage unbalance and overstress to other switching devices from a delay of fault detection. The proposed method has been verified by simulation and experiment.

Parallel Optimal Power Flow Using PC Clustering (PC 클러스터링을 이용한 병렬 최적조류계산에 관한 연구)

  • Kim, Cheol-Hong;Mun, Kyeong-Jun;Kim, Hyung-Su;Park, J.H.;Kim, Jin-Ho;Lee, Hwa-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.190-193
    • /
    • 2004
  • Optimal Power Flow (OPF) is becoming more and more important in the deregulation environment of power pool and there is an urgent need of faster solution technique for on-line application. So this paper presents parallel genetic algorithm-tap search for the solution of the OPF. The control variables modeled unit active power outputs, generator-bus voltage magnitudes and transformer-tap settings. A number of functional operating constraints, such as branch flow limits, load bus boltage magnitude limits and generator reactive capabilities are included as penalties in the fitness function. In parallel GA-TS, GA operators are executed for each process. If best fitness of the GA is not changed for several generations, TS operators are executed for the upper three populations to enhance the local searching capabilities. With migration operation, best string of each node is transferred to the neighboring node after predetermined iterations are executed. For parallel computing, we developed a PC-cluster system consisting of 8 PCs. Each PC employs the 2 GHz Pentium IV CPU and is connected with others through ethernet switch based fast ethernet. To show the usefulness of the proposed method, developed algorithm has been tested and compared on an IEEE 30-bus system in the reference paper. From the simulation results, we can find that the proposed algorithm is efficient for the OPF.

  • PDF

Development of a Power Management System for Efficient Power usage of Intelligent Ship (지능형 선박의 효울적인 전력사용을 위한 전력 관리 시스템 개발)

  • Park, Ji-Sang;Jeon, Min-Ho;Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.609-615
    • /
    • 2013
  • As with any ships, adequate power provision is crucial, especially on the ocean navigating ships far from the land. In order to resolve the effective and economic power supply system of any ship in operation, in this paper, we propose a power management system that intelligently controls the power supply in ships. Power management systems in this design consist of a power load detection system, a generator configuration system, and a power monitoring system respectively. The CT / PT sensor is used to measure amount of current and power in the power detection system, and according to the collected information from various sensor, the generator configuration system will switch on and off the main / sub generator effectively. Finally, the power monitoring system will display all status information of this power management system at a glance for users. This power management systems implemented in this paper is evaluated via real-time experiments, which works well as designed, and certified by KSCIEC61892-1:2012 and KSCIEC60950-1:2008.

Design of IoT-based Energy Monitoring System for Residential Building (IoT 기반 주택형 건물 에너지 모니터링 시스템 설계)

  • Lee, Min-Goo;Jung, Kyung-Kwon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1223-1230
    • /
    • 2021
  • Recently, energy resource management is a major concern around the world. Energy management activities minimize environmental impacts of the energy production. This paper presents design and prototyping of a home electric energy monitoring system that provides residential consumers with real time information about their electricity use. The developed system is composed of an in-house sensing system and a server system. The in-home sensing system is a set of wireless smart plug which have an AC power socket, a relay to switch the socket ON/OFF, a CT sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. Each sensing node sends its detection signal to a home gateway via wireless link. The home gateway stores the received signals into a remote database. The server system is composed of a database server and a web server, which provides web-based monitoring system to residential consumers. We analyzed and presented energy consumption data from electrical appliances for 3 months in home. The experimental results show the promising possibilities to estimate the energy consumption patterns and the current status.

Development of Rain Shelter for Chinese Cabbage Rainproof Cultivation (배추재배용 비가림하우스 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Moon, Doo Gyung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.4
    • /
    • pp.293-302
    • /
    • 2014
  • This study was carried out to develop rain shelter which can make an appropriate size and environment for Chinese cabbage rainproof cultivation. Fifty three farms with chinese cabbage rainproof cultivation system have been investigated to set up width and height of rain shelter. Mostly the width of 6m was desired for rain shelter and the height of 1.6m for their eaves, so these values were chosen as the dimensions for rain shelter. After an analysis of their structural safety and installation costs by the specifications of the rafter pipe, Ø$25.4{\times}1.5t$ and 90cm have been set as the size of rafter that such size costs the least. This size is stable with $27m{\cdot}s^{-1}$ of wind velocity and 17cm of snow depth. Therefore it is difficult to apply this dimension to area with higher climate load. In order to sort out such problem, the rain shelter has been designed to avoid damage on frame by opening plastic film to the ridge. Once greenhouse band is loosen by turning the manual switch at the both sides of rain shelter and open button of controller is pushed then switch motor rises up along the guide pipe and plastic film is opened to the ridge. Chinese cabbage can be damaged by insects if rain shelter is opened completely as revealed a field. To prevent this, farmers can install an insect-proof net. Further, the greenhouse can be damaged by typhoon while growing Chinese cabbage therefore the effect of an insect-proof net on structural safety has been analyzed. And then structural safety has been analyzed through using flow-structure interaction method at the wind condition of $40m{\cdot}s^{-1}$. And it assumed that wind applied perpendicular to side of the rain shelter which was covered by insect-proof net. The results indicated that plastic film was directly affected by wind therefore high pressure occurred on the surface. But wind load on insect-proof net was smaller than on plastic film and pressure distribution was also uniform. The results of structural analysis by applying pressure data extracted from flow analysis indicated that the maximum stress occurred at the end of pipe which is the ground part and the value has been 54.6MPa. The allowable stress of pipe in the standard of structural safety must be 215 MPa or more therefore structural safety of this rain shelter is satisfied.

Design and Analysis of a 12 V PWM Boost DC-DC Converter for Smart Device Applications (스마트기기를 위한 12 V 승압형 PWM DC-DC 변환기 설계 및 특성해석)

  • Na, Jae-Hun;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.239-245
    • /
    • 2016
  • In this study, a 12 V PWM boost converter was designed with the optimal values of the external components of the power stage was well as the compensation stage for smart electronic applications powered by a battery device. The 12 V boost PWM converter consisted of several passive elements, such as a resistor, inductor and capacitor with a diode, power MOS switch and control IC chip for the control PWM signal. The devices of the power stage and compensation stage were designed to maintain stable operation under a range of load conditions as well as achieving the highest power efficiency. The results of this study were first verified by a simulation in SPICE from calculations of the values of major external elements comprising the converter. The design was also implemented on the prototype PCBboard using commercial IC LM3481 from Texas Instruments, which has a nominal output voltage of 12 V. The output voltage, ripple voltage, and load regulation with the line regulation were measured using a digital oscilloscope, DMM tester, and DC power supply. By configuring the converter under the same conditions as in the circuit simulation, the experimental results matched the simulation results.

Efficient Channel Scheduling Technique Using Release Time Unscheduled Channel Algorithm in OBS WDM Networks (OBS WDM 망에서 비 할당된 채널 개방시간을 이용한 효율적인 채널 스케줄링 기법)

  • Cho Seok-man;Kim Sun-myeng;Choi Dug-kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10A
    • /
    • pp.912-921
    • /
    • 2005
  • Optical burst switching(OBS) is a promising solution for building terabit optical routers and realizing If over WDM. Channel scheduling Algorithm for reduce contention is one of the major challenges in OBS. We address the issue of how to provide basic burst channel scheduling in optical burst switched WDM networks with fiber delay lines(FDLs). In OBS networks the control and payload components or a burst are sent separately with a time gap. If CHP arrives to burst switch node, because using scheduling algorithm for data burst, reservation resources such as wavelength and transmit data burst without O/E/O conversion, because contention and void between burst are happened at channel scheduling process for data burst that happened the link utilization and bust drop probability Existent proposed methods are become much research to solve these problems. Propose channel scheduling algorithm that use Release Time of bust to emphasize clearance between data and data dissipation that is happened in data assignment in this treatise and maximize bust drop probability and the resources use rate (RTUC : Release Time Unscheduled Channel). As simulation results, Confirmed that is more superior in terms of data drop and link utilization than scheduling algorithm that is proposed existing. As simulation results, confirmed improved performance than scheduling algorithm that is proposed existing in terms of survival of burst, efficiency resource and delay. However, In case load were less, degradation confirmed than existent scheduling algorithm relatively, and confirmed that is superior in data drop aspect in case of load increased.

Design of an Energy Management System for On-Chip Solar Energy Harvesting (온칩 태양 에너지 하베스팅을 위한 에너지 관리 시스템 설계)

  • Jeon, Ji-Ho;Lee, Duck-Hwan;Park, Joon-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.2
    • /
    • pp.15-21
    • /
    • 2011
  • In this paper, an energy management circuit for solar energy harvesting system is designed in $0.35{\mu}m$ CMOS technology. The solar energy management system consists of an ISC(Integrated Solar Cell), a voltage booster, and an MPPT(Maximum Power Point Tracker) control unit. The ISC generates an open circuit voltage of 0.5V and a short circuit current of $15{\mu}A$. The voltage booster provides the following circuit with a supply voltage about 1.5V. The MPPT control unit turns on the pMOS switch to provide the load with power while the ISC operates at MPP. The SEMU(Solar Energy Management Unit) area is $360{\mu}m{\times}490{\mu}m$ including pads. The ISC area is $500{\mu}m{\times}2000{\mu}m$. Experimental results show that the designed SEMU performs proper MPPT control for solar energy harvested from the ISC. The measured MPP voltage range is about 370mV∼420mV.

Development of Elbow Wearable Robot for Elderly Workers (고령층 근로자들을 위한 팔꿈치 착용형 로봇의 개발)

  • Lee, Seok-Hoon;Lee, Si-Haeng;Kim, Jung-Yup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.617-624
    • /
    • 2015
  • This paper describes the development of a wearable robot to assist the elbow muscle for use by elderly workers in aging societies. Various previously developed wearable robots have drawbacks in terms of their price, portability, and slow recognition of the wearer's intention. In this paper, emphasis is placed on the following features to minimize these drawbacks. The first feature is that an actuator is attached only at the elbow joint that withstands the highest moment during arm motion to reduce the weight, volume, and price of the robot and increase its practicality. The second is that operation of the wearable robot is divided into two modes, a tracking mode and a muscle strengthening mode, and the robot can automatically switch between these modes by analyzing the wearer's intention through the brachial muscle strength measuring device developed in this study. The assistive performance of the developed wearable robot is experimentally verified by motion tracking experiments without an external load and muscle strengthening experiments with an external load. During the muscle strengthening experiments, the power of the muscle of the upper arm is measured by a commercial electromyography (EMG) sensor. Motion tracking performance at a speed of $120^{\circ}/s$ and muscle assistance of over 60 % were obtained using our robot.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.