Development of 6-component Load Cell Using Plate Beams (평판보를 이용한 6분력 로드셀 개발에 관한 연구)

  • 김갑순;이세헌;엄기원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.109-115
    • /
    • 1998
  • This paper describes the development of a 6-component load cell with plate beams which may be used to measure forces Fx, Fy, Fz and moments Mx, My, Mz simultaneously in industry. We have analyzed the bending strains on the surface of the beams under forces or moments by using Finite Element Method and designed the sensing elements of 6-component load cell. We have also determined the attachment location of strain gages of each load cell and fabricated 6-component load cell. To evaluate the rated strain and interference error of each load cell, we have carried out characteristic test of 6-component load cell.

  • PDF

A Study on the Efficiency of a Load Sensing Main Control Valve Using SimulationX (SimulationX를 이용한 부하 감지형 메인 컨트롤밸브의 효율에 관한 연구)

  • Kim, Dong Myoung;Lee, Jung Min;Jung, Won Jee;Jang, Joo Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.87-95
    • /
    • 2016
  • In this study, we develop a model of an open center and load-sensing system and for a main control valve to analyze system characteristics and efficiency using SimulationX. In order to analyze the operating characteristics of the pressure and flow of the main control valve of an open center system, a test was performed at each port. The reliability of the model was confirmed by comparing the similarity of the analysis results with the test results before analyzing the operating characteristics of the system. Development of the load sensing main control valve was performed by adding a flow sharing valve and a notched shape to the open center system based on it's the proven reliability. The authors performed the simulation under the same load conditions in order to compare the efficiency of the systems. Additionally, the combined operation performance was investigated by means of analyzing the characteristics of flow distribution under different load conditions.

Anti-Saturation Algorithm for a Load Sensing Hydraulic Servo System with Multiple Actuators (다중 작동기를 가진 부하감응 유압서보장치의 포화방지 알고리즘)

  • 이춘호;최필환;김철수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.977-981
    • /
    • 1996
  • A load sensing hydraulic system is widely used to military and commercial mobile applications fur its high running efficiency. Although concept and general control schemes are well known, the poor maneuverability of simultaneous multioperation of actuators still remains to be solved. In this paper, a new control algorithm is proposed to prevent the saturation of the system in such operating conditions, in which the total required flowrate of actuators may exceed the pump supply flowrate. The effectiveness of the proposed algorithm is verified through experiments.

  • PDF

A minimum energy control of a load-sensing hydraulic servo system

  • Kim, S.D.;Cho, H.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.747-752
    • /
    • 1987
  • The dynamic characteristics of a load-sensing hydraulic servo system are complex and highly unstable. Another property of the system is that the setting value of pump compensator is closely related to energy efficiency as well as control performance of the system. This necessitates the development of an effective control algorithm which guarantees good control performance, stability and energy efficiency. This paper considers a suboptimal PID control for the velocity control problem of the load-sensing hydraulic servo system. The results of simulations studies and experiments show that the proposed suboptimal controller can produce much better control performance than nonoptimal controllers and give effective energy efficiency.

  • PDF

Agent-Based Load Balancing Method for Web GIS Services; Web-Based Forest Fire Management System

  • Jo, Yun-Won;Jo, Myung-Hee;Oh, Jeong-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.17 no.4
    • /
    • pp.359-368
    • /
    • 2001
  • The prototype of forest fire management system on Web was studied. In the architecture of this system, one of the most important concerns is to handle load upcoming to Web Server so that it provides Web service without any delay or failure. In order to solve this problem, the agent is designed on dispatcher in a Web server cluster and implemented to distribute load dynamically by considering the information related to load coming to the Web Server such as the number of connection to the Map Server. The proposed forest fire management system has user-friendly interface with the GIS mapping functionality by selecting Map Objects Internet Map Server (MO IMS) as Map Server and is implemented using Java as programming language.

Design and Analysis of Column Type Sensing Element for Large Compact Load Cell (대용량 Compact형 로드셀의 기둥형 감지부 설계 및 해석)

  • Kang, Dae-Im;Shin, Hong-Ho;Kim, Jong-Ho;Park, Yon-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.4
    • /
    • pp.601-607
    • /
    • 2003
  • The column type is used as the sensing element of the load cell to measure the large force in the range of 10$^4$~ 10$^{7}$ N. However. it is not easy to handle the load with large capacity due to its size. It is, therefore, necessary to design a compact load cell with a low aspect ratio. Thus this paper showed the characteristic evaluation of compact load cell with respect to the shape of supporting plate. The supporting plate of the load cell was an annular type with inner(D$_{i}$) and outer(D$_{o}$) diameters. Using the strain distribution obtained from FEM. the supporting plate was designed to get the stable output voltage of the load cell. The three designed supporting plates were manufactured, and the result of characteristic experiment of the load cell, using the 10 MN hydraulic force standard machine, was compared with FEM.M.M.

A High Voltage, High Side Current Sensing Boost Converter

  • Choi, Moonho;Kim, Jaewoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.36-37
    • /
    • 2013
  • This paper presents high voltage operation sensing boost converter with high side current. Proposed topology has three functions which are high voltage driving, high side current sensing and low voltage boost controller. High voltage gate driving block provides LED dimming function and switch function such as a load switch of LED driver. To protect abnormal fault and burn out of LED bar, it is applied high side current sensing method with high voltage driver. This proposed configuration of boost converter shows the effectiveness capability to LED driver through measurement results.

  • PDF

Nondestructive Sensing Evaluation of Ni Nanowire Strands and Carbon Nanotube/Epoxy Composites Using Electro-Micromechanical Techniques (Electro-Micromechanical 시험법을 이용한 Ni Nanowire Strands 및 Carbon Nanotube 강화 에폭시 복합재료의 비파괴 감지능 평가)

  • Jung, Jin-Gyu;Kim, Sung-Ju;Park, Joung-Man
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.269-272
    • /
    • 2005
  • Nondestructive damage sensing and load transferring mechanism of Ni nanowire strands and multi-wall carbon nanotube (MWCNT)/epoxy composites were investigated using electro-micromechanical techniques. MWCNT composite was especially prepared for high volume contents, 50 vol % of reinforcement. Electro-micromechanical techniques were applied to measure apparent modulus and contact resistance of Ni nanocomposites with their alignment and different diameters, and adding contents. Applied cyclic load affected on apparent modulus and electrical properties on nanocomposites due to various inherent properties of each CNMs. Contact resistivity on humidity sensing was a good indicator for monitoring as for multifunctional applications. Further study on actuation as well as sensing will be investigated for the following work continuously.

  • PDF

Broad and stage-based sensing function of HCFRP sensors

  • Wu, Z.S.;Yang, C.Q.
    • Smart Structures and Systems
    • /
    • v.3 no.2
    • /
    • pp.133-146
    • /
    • 2007
  • This paper addresses a new type of broad and stage-based hybrid carbon fiber reinforced polymer (HCFRP) sensor that is suitable for the sensing of infrastructures. The HCFRP sensors, a type of composite sensor, are fabricated with three types of carbon tows of different strength and moduli. For all of the specimens, the active materials are carbon tows by virtue of their electrical conductivity and piezoresistivity. The measurement principles are based on the micro- and macro-fractures of different types of carbon tows. A series of experiments are carried out to investigate the sensing performances of the HCFRP sensors. The main variables include the stack order and volume fractions of different types of carbon tows. It is shown that the change in electrical resistance is in direct proportion to the strain/load in low strain ranges. However, the fractional change in electrical resistance (${\Delta}R/R_0$) is smaller than 2% prior to the macrofractures of carbon tows. In order to improve the resistance changes, measures are taken that can enhance the values of ${\Delta}R/R_0$ by more than 2 times during low strain ranges. In high strain ranges, the electrical resistance changes markedly with strain/load in a step-wise manner due to the gradual ruptures of different types of carbon tows at different strain amplitudes. The values of ${\Delta}R/R_0$ due to the fracture of high modulus carbon tows are larger than 36%. Thus, it is demonstrated that the HCFRP sensors have a broad and stage-based sensing capability.

Mechanical and Electrical Characteristics of Concrete Members Enlarged with Self-Sensing Cementitious Materials for Repair (자기감지형 보수재로 단면증타된 콘크리트 부재의 역학 및 전기적 특성 )

  • Gun-Cheol Lee;Geon-Woo Im;Chang-Min Lee;Sung-Won Hong;Young-Min Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.139-146
    • /
    • 2023
  • In this study, compressive strength and adhesion strength were measured as repair materials to evaluate the mechanical and electrical properties of compression and shear specimens with self-sensing repair materials. As a result of the experiment, the strength improvement rate of the compression test specimen was higher than the section enlargement area ratio, but the shear test specimen did not show an improvement in strength as much as the section enlargement area ratio. Compression experiments under load showed high correlation between FCR-Strain and FCR-Stress, confirming self-sensing performance. However, the shear test did not show as much correlation as the compression test. Accordingly, it is judged that the self-sensing repair material is suitable for the compression member on which the compression load acts in the building.