• Title/Summary/Keyword: Load resistance

Search Result 2,437, Processing Time 0.033 seconds

Voltage Step-down Characteristics of Modified Ring/Dot-type Piezoelectric Transformer using Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3 Ceramics (Pb[(Mn1/3Sb2/3)0.05Zr0.475]O3세라믹스를 이용한 변형 Ring/Dot형 압전세라믹 변압기의 감압특성)

  • 남성진;남효덕;손준호;이준형
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.2
    • /
    • pp.171-177
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum cutout voltage appears increased about 0.2% as the load resistance increased from 10 to 150 Ω. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 Vpp and 120 Ω, respectively.

An Antenna-Integrated Oscillator Design Providing Convenient Control over the Operating Frequency and Output Power (동작주파수 및 출력파워 조절이 용이한 신호생성용 안테나 설계)

  • Lee, Dong-Ho;Lee, Jong-In;Kim, Mun-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • A new design for easily controlling operating frequency of an antenna-integrated planar oscillator is introduced. The oscillator circuit of a broadband negative-resistance active part and a passive load including a patch antenna. The patch resonance is used for determining the oscillation frequency. This design reduces the possibility of mismatch between antenna radiation and oscillation frequencies. To achieve optimum output power, load-pull simulation for the negative-resistance circuit is used. The load-pull simulation shows the feed point and the delay of feed line can affect the oscillation power. Two negative-resistance circuits capable of supporting oscillation over full C-band and X-band are fabricated. The oscillation frequency, output power and phase noise for different patch antennas are measured.

  • PDF

Electrical Properties of Thickness-Vibration-Mode Multilayer Piezoelectric Transformer using Low Temperature Sintering (Pb,Ca,Sr,)(Ti,Mn,Sb)O3 Ceramics (저온소결 (Pb,Ca,Sr,)(Ti,Mn,Sb)O3 세라믹스를 이용한 두께진동모드 적층 압전 변압기의 전기적 특성)

  • Yoo, Ju-Hyun;Yoo, Kyung-Jin;Kim, Do-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.11
    • /
    • pp.948-952
    • /
    • 2007
  • In this study, a low temperature sintering multilayer piezoelectric transformer for a DC-DC converter was manufactured using $(Pb,Ca,Sr,)(Ti,Mn,Sb)O_3$ ceramics. Its electrical properties were investigated according to the variation in frequency and load resistance. The voltage step-up ratio of the multilayer piezoelectric transformer showed a maximum value at a resonant frequency of input part and increased with an increase of load resistance. The efficiency of the multilayer piezoelectric transformer showed the highest value at a load resistance of 17 $\Omega$. The output power was increased with increasing input voltage. Temperature increase of the multilayer piezoelectric transformer was increased with the increase of output power. At the load resistance of 17 $\Omega$, the multilayer piezoelectric transformer showed the temperature rises of about $20^{\circ}C$ at the output power of 18 W, and stable driving characteristics.

Fabrication and Characteristics of Ring-Dot type Piezoelectric Transformer (Ring-dot형 감압형 압전변환기의 제작과 특성)

  • Nam, Sung-Jin;Lee, Yeung-Min;Nam, Hyo-Duk;Sohn, Joon-Ho;Lee, Joon-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.722-725
    • /
    • 2004
  • Voltage step-down characteristics in Ring/Dot type piezoelectric transformer were examined as a function of the area of input electrode when the area of output electrode is fixed. The effects of driving frequency and load resistance on the voltage step-down characteristics were also examined. Voltage gain was greatly dependent on the driving frequency and load resistance, and showed a maximum gain at resonance frequency of the step-down transformer. The frequency where the maximum output voltage appears increased about 0.2% as the load resistance increased from 10 to $150\Omega$. As the area of input electrode increased, the voltage gain and the efficiency of the transformer increased. Frequency dependence of efficiency of the step-down transformer revealed a similar tendency with the voltage gain curves. The maximum efficiency remarked 94% when the input voltage and the load resistance were 20 $V_{PP}$ and $120\Omega$, respectively.

  • PDF

Physical Properties of Cement Boards Mixed Pearlite and Expanded Graphite (펄라이트와 팽창흑연을 혼입한 시멘트 보드의 물리적 특성)

  • Lee, Ju-Won;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.65-66
    • /
    • 2023
  • Recently, the importance of improving air quality has been greatly highlighted due to environmental problems such as indoor air pollution, and efforts are being made to improve indoor air quality not only in Korea but also around the world. In this situation, this study aims to study the physical properties of cement boards using pearlite with excellent physical adsorption performance due to micropores in materials, expanded graphite that is widely used as a flame retardant to prevent heat transfer in the event of a fire. The experimental items are bending fracture load and impact resistance. The bending destruction load at the fiber mixing rates 1, 2, 3, and 4 (%) did not meet the standard 140N, but the bending destruction load at 5% was 168.2N, and the impact resistance of the fiber mixing rates 1 and 2 (%) could not be measured due to cracks and damage, and the impact resistance at 3, 4, and 5 (%).

  • PDF

Adaptive Feedback Linearization Control Based on Stator Fluxes Model for Induction Motors

  • Jeon, Seok-Ho;Park, Jin-Young
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.253-263
    • /
    • 2002
  • This paper presents an adaptive feedback linearization control scheme for induction motors using stator fluxes. By using stator flukes as states, overparameterization is prevented and control inputs can be determined straightforwardly unlike in existing schemes. This approach leads to the decrease of the relative degree for the flux modulus and thus yields a simpler control algorithm than the prior results. In this paper. adaptation schemes are suggested to compensate for the variations of stator resistance. rotor resistance and load torque. In particular, the adaptation to the variation of stator resistance with a feedback linearization control is a new trial. In addition, to improve the convergence of rotor resistance estimation, the differences between stator currents and its estimates are used for the parameter adaptation. The simulations show that torque and flux are controlled independently and that the estimates of stator resistance, rotor resistance, and load torque converge to their true values. Actual experiments on a 3.7㎾ induction motor verify the effectiveness of the proposed method.

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.

Development of Load and Resistance Factor Design of Mound Breakwater Against Circular Failure (경사식 방파제 원호파괴에 대한 하중저항계수 설계법 개발)

  • Kim, unghwan;Huh, Jungwon;Lee, Kicheol;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.205-214
    • /
    • 2019
  • Load and resistance factor design of mound breakwater against circular failure was developed in this study. To achieve the goal, uncertainties of parameters of soils, mound, and concrete cap were determined. Eight design cases of domestic mound breakwaters were collected and analyzed. Monte Carlo Simulation was implemented to determine the most critical slip surfaces of the design cases. Using the results of Monte Carlo Simulation, First-Order Reliability Method (FORM) was used to perform reliability analyses. Optimal load and resistance factors were calculated using the reliability analysis results and final load and resistance factors were proposed based on the calculated optimal factors.

Calibration of Load and Resistance Factors in KCI Code Based on Domestic Data (국내 통계자료를 이용한 설계기준의 하중저항계수 검증)

  • Kim, Jee-Sang;Kim, Jong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.495-501
    • /
    • 2011
  • The load combinations in current KCI Design Code are determined with reference to those in ACI 318-05, which adopts the LRFD (load and resistance factor design) format. The load and resistance factors in LRFD format should be determined to meet the required levels of reliability index or probability of failure for various predetermined failure modes, which are also based on the statistical data reflecting locality and contemporary situation. However, the current KCI Design Code has been written utilizing foreign data, because of insufficiency in accrued data in Korea. This study considered the current safety levels of KCI Code based on published domestic data to evaluate appropriateness of the current KCI regulations. Based on the calibrated reliability index of the existing Code, the new resistance factors are suggested. The results presented in this paper can be considered as a basic research for establishment of unique design format for future Korean Codes.

Constructing Database and Probabilistic Analysis for Ultimate Bearing Capacity of Aggregate Pier (쇄석다짐말뚝의 극한지지력 데이터베이스 구축 및 통계학적 분석)

  • Park, Joon-Mo;Kim, Bum-Joo;Jang, Yeon-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.8
    • /
    • pp.25-37
    • /
    • 2014
  • In load and resistance factor design (LRFD) method, resistance factors are typically calibrated using resistance bias factors obtained from either only the data within ${\pm}2{\sigma}$ or the data except the tail values of an assumed probability distribution to increase the reliability of the database. However, the data selection approach has a shortcoming that any low-quality data inadvertently included in the database may not be removed. In this study, a data quality evaluation method, developed based on the quality of static load test results, the engineering characteristics of in-situ soil, and the dimension of aggregate piers, is proposed for use in constructing database. For the evaluation of the method, a total 65 static load test results collected from various literatures, including static load test reports, were analyzed. Depending on the quality of the database, the comparison between bias factors, coefficients of variation, and resistance factors showed that uncertainty in estimating bias factors can be reduced by using the proposed data quality evaluation method when constructing database.