Browse > Article
http://dx.doi.org/10.4334/JKCI.2011.23.4.495

Calibration of Load and Resistance Factors in KCI Code Based on Domestic Data  

Kim, Jee-Sang (Dept. of Civil Engineering, Seokyeong University)
Kim, Jong-Ho (BNG Consultants Co. Ltd.)
Publication Information
Journal of the Korea Concrete Institute / v.23, no.4, 2011 , pp. 495-501 More about this Journal
Abstract
The load combinations in current KCI Design Code are determined with reference to those in ACI 318-05, which adopts the LRFD (load and resistance factor design) format. The load and resistance factors in LRFD format should be determined to meet the required levels of reliability index or probability of failure for various predetermined failure modes, which are also based on the statistical data reflecting locality and contemporary situation. However, the current KCI Design Code has been written utilizing foreign data, because of insufficiency in accrued data in Korea. This study considered the current safety levels of KCI Code based on published domestic data to evaluate appropriateness of the current KCI regulations. Based on the calibrated reliability index of the existing Code, the new resistance factors are suggested. The results presented in this paper can be considered as a basic research for establishment of unique design format for future Korean Codes.
Keywords
LRFD; KCI design code; reliability index; load factor; resistance factor;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ellingwood, B., et al., Development of a Probability Based Load Criterion for American National Standard A58. NBS SP 577,US Development of Commerce, 1980, pp. 85-93.
2 Nowak, A. S. and Lind, N. C., "Practical Bridge Code Calibration," Journal of Structural Division, ASCE, Vol. 105, No. ST12, 1979, pp. 2497-2510.
3 황의승, 백인열, "신뢰도기반 설계기준의 기본이론 및 설계일반," 학림사, 2006, pp. 35-37.
4 Rackwitz, R. and Fiessler, B., "Structural Reliability Under Combined Random Load Sequences," Computer and Structures, Vol. 9, 1978, pp. 489-494.   DOI   ScienceOn
5 김종호, "콘크리트구조설계기준의 신뢰도 검증," 석사학위논문, 서경대학교, 2011, pp. 20-36.
6 한국콘크리트학회, 성능중심 콘크리트 구조설계기준개발, 한국콘크리트학회, 2011, pp. 16-28.
7 김상효 등, 구조물의 신뢰성에 관한 연구-고정하중.적재하중 및 풍하중하에서의 RC 건물, 한국건설기술연구원 결과보고서, 한국건설기술연구원, 1989, pp. 110-125.
8 Nowak, Andrzej S. and Szerszen, Maria M., "Calibration of Design Code for Buildings(ACI 318): Part 2-Reliability Analysis and Resistance Factors," ACI Structural Journal, Vol. 100, No. 3, 2003, pp. 383-391.
9 한국콘크리트학회, 콘크리트 구조설계기준해설, 기문당, 2007, pp. 61-62.
10 조효남, 지광습, 윤정현, 김이현, 최현호, 이광민, 이상윤, 신동완, 구조신뢰성공학, 구미서관, 2008, pp. 163-188.
11 Comite Euro-International du Beton, CEB-FIP Model Code 1990, Thomas Telford, London. 1993, pp. 17-30.
12 American Concrete Institute, Building Code Requirements for Structural Concrete (ACI 318-05) and Commentary (ACI318R-05), Framington Hills, American Concrete Institute, 2005, pp. 115-121.
13 American Association of State Highway and Transportation Officials, AASHTO LRFD Bridge Design Specifications, Washington, DC, 2006, pp. 5-23-5-24.