• 제목/요약/키워드: Load reduction factor

검색결과 233건 처리시간 0.028초

유도발전기 역률 보상 콘덴서와 직렬 리액터의 동작 분석 (Operating Analysis of Power Factor Compensation Condenser and Series Reactor in the Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.593-598
    • /
    • 2017
  • Induction generator is always required reactive power in order to generate a rotating magnetic field as an inductive load. The reactive power must be continuously supplied to the induction generator as well as load of distribution system from the power supply side. So the power factor of the power supply side during the induction generation operation is low. Condenser is installed in order to raise the low power factor of the induction generator. Switching transients occurs when the power supply of the capacitor is turned on in order to ensure the low power factor. When using the reactor in series with the capacitor in order to reduce the influence of switching transient, it can affect the reactive power by the condenser voltage rises. In this study, we analyzed the operating characteristics for power and power factor of induction generator in accordance with the presence or absence of the application of the serial reactors for switching transients reduction of the condenser and the condenser for power factor correction.

낙엽송 집성재의 Bolt, Drift Pin 접합부의 전단강도 성능 평가 - 접합구 직경, 세장비, 끝면거리가 강도에 미치는 영향 - (Shearing Strength Properties of Bolted, Drift-Pinned Joints of the Larix Glulam - Effects of Fastener Diameter, Slenderness and End-distance on Strength Properties -)

  • 김건호;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권1호
    • /
    • pp.69-78
    • /
    • 2008
  • 국내산 낙엽송 집성재 볼트, 드리프트 핀 접합부의 내력성능평가를 위해 인장형 전단강도시험을 실시하였다. 인장형 전단시편은 강판삽입형 볼트, 드리프트 핀 접합부 시편과 강판측재형 볼트접합부시편으로 제작하였다. 실험에 사용된 볼트와 드리프트 핀의 직경은 12, 16, 20 mm였다. 시편의 접합구멍은 끝면거리 5, 7 d로 제작하였고 인장하중은 섬유평행방향으로 가하였다. 끝면거리에 따른 접합부의 내력성능을 검토하고 Larsen의 항복추정식을 통해 항복하중을 실측항복하중과 비교하였다. 설계표준 시 끝면거리 7 d의 항복하중을 기준으로 5 d의 저감계수를 산출하였다. 본 연구의 결과는 다음과 같다. 1. 강판삽입형 접합부에서 드리프트 핀 접합부의 평균최대하중은 직경이 증가함에 따라 볼트 접합부보다 3~30% 정도 크게 나타났다. 볼트 접합부의 경우 강판측재형의 평균최대하중은 강판삽입형보다 1.54~2.07배 크게 나타났다. 동일 직경에서 끝면거리 7 d의 평균최대하중이 5 d보다 8~44% 정도 크게 나타났다. 2. 강판삽입형 접합부의 지압응력은 드리프트 핀 접합부가 볼트보다 1.16~1.41배 더 크게 나타났으며, 7 d가 5 d보다 1.37~1.86배 크게 나타났다. 또한 드리프트 핀 접합부의 세장비는 7.5 이하, 강판삽입형 볼트 접합부의 세장비는 6 이하에서 양호한 내력성능을 보였다. 3. 실측 항복하중과 Larsen이 제안한 항복하중 추정식에 의해 얻어진 항복하중값의 비는 강판삽입형 접합부의 경우 0.80~1.10, 강판측재형 접합부는 0.75~1.46이었다. 4. 끝면거리 7 d의 항복하중을 기준으로 강판삽입형 볼트접합부의 경우 12 mm 접합부의 저감계수(Ke)는 0.89, 16 mm는 0.93, 20 mm는 0.85였다. 강판삽입형 드리프트 핀 접합부의 경우 12 mm는 0.89, 16 mm는 0.93, 20 mm는 0.93이었다. 강판측재형 직경 12 mm 볼트접합부의 저감계수는 0.79, 16 mm는 0.80이었다.

유도전동기에 대한 역률 보상설비의 특성 해석 (A Characteristic Study on the Power Factor Correction Application for Induction Motor)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.25-31
    • /
    • 2008
  • 유도전동기의 자계는 전류의 방향에 따라 자화 및 감자되는 특성을 가지고 있다. 전통기의 자계를 형성하는데 필요한 자화전류는 유도성으로 무효전력의 대부분을 차지하고 있다. 무효전력은 유도전동기가 동작하는데 필요한 자계를 지속시키는 역할을 한다. 유도전통기의 역률은 낮은 편이므로 역률 보상이 필요하다. 유도전동기를 정격출력보다 낮은 부하로 운전할 경우 유효전력에 비해 무효성분의 비율증가로 역률이 낮아진다. 역률 보상장치의 용량은 전동기 정격에 맞도록 설치하기를 권고하고 있다. 그러나 부하의 운전상황에 따라 역률 보상용 커패시터 값은 수정하기가 어렵다. 본 논문에서는 저압 소용량 유도 전동기에 연결된 부하의 변화에 따라 전력 및 역률의 동작특성을 해석한 결과 기존에 제시된 낮은 역률 보상용 파라미터는 수정되어야 함을 확인하였다.

충격계수 응답스펙트럼을 이용한 단경간 교량의 내하력 평가 (Load Carrying Capacity Evaluation of Single Span Bridge using Impact Factor Response Spectrum)

  • 이후석;노화성;박경훈
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.730-736
    • /
    • 2016
  • 이전 연구에서 기존의 재하실험을 통한 교량의 공용 중 내하력 평가방법을 개선하기 위하여 충격계수 응답스펙트럼과 그에 따른 내하성능 변화 추정 방법이 제안되었다. 본 논문에서는 제안된 방법의 적용성을 검증하기 위하여 공용 중인 단순지지 단경간 교량에 대한 현장 동적특성 평가 실험을 수행하였다. 실험을 통해 상시 교통하중 상태에서 무선 가속도계를 이용하여 교량의 고유진동수 도출이 가능한 수준의 동특성 응답을 획득할 수 있었다. 대상 교량의 가속도 데이터로부터 동적거동은 1차 모드에 지배되며 준공 당시에 비해 공용 기간의 증가로 인해 고유진동수가 감소한 것으로 나타났다. 충격계수 응답스펙트럼으로부터 대상 교량의 발생 가능한 최대 충격계수를 추정하였다. 도출된 이전 및 현재의 고유진동수와 충격계수를 바탕으로 성능감소계수를 적용한 내하력 평가방법을 이용하여 성능변화를 추정하였다. 이전에 비해 공용내하력이 감소하였으나 설계 활하중을 상회하여 내하성능에는 문제가 없는 것으로 나타났다. 상시 교통하중 하에서의 가속도 계측 데이터와 충격계수 응답스펙트럼을 이용하는 제안된 내하성능 변화 추정 방법은 실제 교량에 적용 가능할 것으로 판단된다.

지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축 (CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump)

  • 이건우;이상중;양성덕
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.349-354
    • /
    • 2008
  • 2008년 8월 우리나라는 온실효과로 인한 기후변화 대응 역량을 강화하고, 에너지의 안정적 공급과 효율화 체계를 구축하기 위한 방안으로 '제1차 국가에너지기본계획'을 발표하였다. 이에 따르면 우리나라는 세계 10위의 에너지다소비 국가이자, 그 중 97% 이상을 해외 수입에 의존하는 나라로서 신재생에너지설비의 중요성이 크게 부각되고 있다. 본 논문은 일반적인 건물의 난방설비로 이용되고 있는 가스와 유류설비를 지열히트펌프로 대체함으로서, 전력계통의 부하율을 향상시키는 방안을 제시하였으며, 이에 따른 에너지비용 절감과 온실가스의 감축방안을 정량적으로 제시하였다.

  • PDF

회전익기용 엔진 감속 기어열의 웹 형상 최적화 (Optimization of Gear Webs for Rotorcraft Engine Reduction Gear Train)

  • 김재승;김수철;손종현;문상곤;이근호
    • 한국항공우주학회지
    • /
    • 제48권12호
    • /
    • pp.953-960
    • /
    • 2020
  • 본 논문은 회전익기용 엔진 감속기 주 기어열의 기어 웹 형상 최적화에 대해 기술하였다. 최적화 목표는 총중량, 전달 오차, 정렬 오차, 치면 하중 분포 계수 값의 최소화로 설정하였으며, 기어의 웹 두께, 웹과 축의 연결 위치, 웹과 림의 연결 위치를 설계변수로 선정하였다. 최적화 과정에서 기어의 웹, 축, 림은 3D 캐드 모델로부터 유한요소 모델로 변환되었으며, 기어 해석 프로그램 MASTA에 입력되었다. 최적화 알고리즘은 NSGA-II를 사용하였다. 최적화 결과 주 기어열의 총중량, 전달 오차, 정렬 오차, 치면 하중 분포 계수 값은 모두 감소하였으며, 최대 응력도 안전한 수준으로 나타나서 전반적으로 기어 성능이 개선되었음을 확인하였다.

선간전압과 상전압에 대한 전압불평형율의 비교 (Comparison of Voltage Unbalance Factor for Line and Phase Voltage)

  • 김종겸;박영진;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.403-407
    • /
    • 2005
  • Most of the loads in industrial power distribution systems are balanced and connected to three power systems. However, voltage unbalance is generated at the user's 3-phase 4-wire distribution systems with single & three phase. Voltage unbalance is mainly affected by load system rather than power system. Unbalanced voltage will draws a highly unbalanced current and results in the temperature rise and the low output characteristics at the machine. It is necessary to analyse correct voltage unbalance factor for reduction of side effects in the industrial sites. Voltage unbalance is usually defined by the maximum percent deviation of voltages from their average value, by the method of symmetric components or by the expression in a more user-friendly form which requires only the three line voltage readings. If the neutral point is moved by the unbalanced load at the 3-phase 4-wire system. Line and phase voltage unbalance leads to different results due to zero-sequence component. So that it is difficult to analyse voltage unbalance factor by the conventional analytical method, This paper presents a new analytical method for phase and line voltage unbalance factor in 4-wire systems. Two methods indicate exact results.

IEC 저압간선의 허용전류 감소계수에 관한 연구 (A Study on Reduction Factor in Allowable Current of IEC Low-Voltage Wire)

  • 송영주;임명환;최대원;김도형;염성배
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.100-108
    • /
    • 2010
  • A low voltage wire should be used considering that a load used in the end is a low voltage. In regard to these wires, there are needs for research about the wire thickness calculation in accordance with IEC standard because the standardization process for IEC (KS standard) was completed on June 30, 2005, and they stopped producing NEC-standard products by the order from Korean Agency for Technology and Standards under Ministry of Knowledge Economy (former Ministry of Commerce, Industry and Energy) since July 1, 2006. This study compared, in terms of the thickness calculation of low voltage wire, a reduction factor application by IEC standard about allowed current and an application for calculation of voltage drop. It also proposed the formula for IEC standard to decrease errors and resolve the difficulty of standardized calculation by analyzing the difference between simplified formula and standardized formula that are the most frequently used calculation method of voltage drop.

Correlation of internal and external pressures and net pressure factors for cladding design

  • Bodhinayake, Geeth G.;Ginger, John D.;Henderson, David J.
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.219-229
    • /
    • 2020
  • Net pressures on roofs and walls of buildings are dependent on the internal and external pressure fluctuations. The variation of internal and external pressures are influenced by the size and location of the openings. The correlation of external and internal pressure influences the net pressures acting on cladding on different parts of the roof and walls. The peak internal and peak external pressures do not occur simultaneously, therefore, a reduction can be applied to the peak internal and external pressures to obtain a peak net pressure for cladding design. A 1:200 scale wind tunnel model study was conducted to determine the correlations of external and internal pressures and effective reduction to net pressures (i.e., net pressure factors, FC) for roof and wall cladding. The results show that external and internal pressures on the windward roof and wall edges are well correlated. The largest ${\mathcal{C}}_{{\check{p},net}$, highest correlation coefficient and the highest FC are obtained for different wind directions within 90° ≤ θ ≤ 135°, where the large openings are on the windward wall. The study also gives net pressure factors FC for areas on the roof and wall cladding for nominally sealed buildings and the buildings with a large windward wall opening. These factors indicate that a 5% to 10% reduction to the action combination factor, KC specified in AS/NZS 1170.2(2011) is possible for some critical design scenarios.

교량의 충격계수에 관한 연구 (A Study on the Impact Factor of Bridges)

  • 윤일로;류택은
    • 한국산업융합학회 논문집
    • /
    • 제7권2호
    • /
    • pp.161-166
    • /
    • 2004
  • The impact factor of bridges is analyzed based on experimental data to examine the characteristics of the dynamic responses of bridges. The experimental impact factors are compared with the impact factor of Korean Highway Design Specification and Japan T-load in terms of the span length. According to the superstructural types of bridges, the variation of the impact factor is analyzed. When vehicles are passing on a bridge, the dynamic effect acts on the bridge impact factor more than at the time of design because of the velocity of vehicles, the surface roughness reduction due to the deterioration of the bridge deck pavement, and the disconnection of the bridge entrance and the expansion joint. Because the actual value is greater than the expected value at the time of design, the dynamic response of the bridge accelerates the deterioration of the bridge due to the accumulation of fatigue, and the bridge's life-time is shortened and can have an influence on the serviceability and safety of the bridge.

  • PDF