• Title/Summary/Keyword: Load reduction

Search Result 2,367, Processing Time 0.027 seconds

Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System (전동 블라인드 내장형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구)

  • Choi, Gyeong-Seok;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.429-435
    • /
    • 2010
  • Although recently revised building code requires 15~20% increased thermal insulation performance for window systems, since the code is focusing on winter heat loss, it is not satisfactory to contribute on reducing rapidly rising cooling load in summer. Window systems have great impact on building heat gain and loss. Therefore technological development for window system specialized in shading solar gain in summer is an urgent matter. This study evaluates the performance of sun shading and thermal insulation for blind integrated window system. Also, computer simulation evaluates the effect of heating and cooling energy consumption reduction for an individual unit(floor area of $85m^2$) of a multi-family housing. Physibel Voltra, a heat transfer analysis software, was used to analyse the effect of energy consumption reduction, and the energy load was converted to the cost to compare the actual effect of economical benefit.

A Study on the Thermal Load Patterns for a Exterior Wall in a House According to a Variation of Earth Sheltering Thickness (복토 주택의 외벽면 복토 두께 변화에 따른 열부하 패턴에 관한 연구)

  • Lee, Jae-Hyuk;Choi, Won-Ki;Suh, Seung-Jik;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.807-812
    • /
    • 2008
  • The various attempts is made to solve the energy and environment problems. In addition, people interested in their life quality want the more eco-friendly living space. So we suggested that the earth-sheltered house could be one of the eco-friendly and low energy consuming houses to meet the social interest. And we also made data for design of the earth-sheltered house to be applicable to climate of Korea. In this study, a simulation was performed to estimate a boundary temperature according to earth sheltering thickness at the earth-sheltered part(exterior wall) in the case of earth sheltering on the plane ground not using a sloped site. And we analyzed the reduction of a thermal load by using this boundary temperature. We also compared a case of earth sheltering at the vertical wall with a case of earth sheltering at the roof to know the thermal reduction effect of a case of earth sheltering at the vertical wall.

  • PDF

Study on Fresh Air Load Reduction System by Using Geothermal Energy - Effect on Thermal Characteristic arid Air Pattern of System by Opening Configuration - (지열을 이용한 공조외기부하저감 시스템에 관한 연구 -지하피트 공간 내의 개구부 형상이 시스템의 열적 특성 및 기류성상에 미치는 영향-)

  • Son Won-Tug;Lee Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1092-1100
    • /
    • 2004
  • This paper presents the effect of opening configuration on the thermal behavior and air pattern of earth tube system. The earth tube system is a fresh air load reduction system by using underground double floor space for air-conditioning. In order to analyze the effect of opening configuration on thermal performance of this system and air pattern in underground double floor space quantitatively, we used a model dealing with tree-dimensional profile of wind velocity and temperature in underground double floor space. In conclusion, it is confirmed that heat exchange of a fresh air is mainly performed with upper and lower wall in underground double floor space, and that heat exchange area increased by installing the opening near the wall.

Numerical Investigation on Load Supporting Mechanism of a Pile Constructed above Underground Cavity (공동이 존재하는 암반에 시공된 말뚝기초의 하중지지 메카니즘에 관한 수치해석 연구)

  • Choi, Go-Ny;Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.1
    • /
    • pp.5-16
    • /
    • 2011
  • This paper presents the results of a three-dimensional finite element analysis on load supporting mechanism of pile constructed above underground cavity in limestone rock formation. Considering a wide range of cavity conditions, the behavior of pile was studied using the bearing capacity, rock yielding pattern, stress distribution and deformation of pile head and the cavity. The results indicate that the load transfer mechanism of pile, rock yielding pattern and the reduction of bearing capacity of pile significantly vary with the location, size and length of cavity. Based on the results, graphical solutions defining the reduction of the bearing capacity with specific cavity conditions were suggested.

Determination of Incentive Level of Direct Load Control using Monte Carlo Simulation with Variance Reduction Technique (몬테카를로 시뮬레이션을 이용한 직접부하제어의 제어지원금 산정)

  • Jeong Yun Won;Park Jong Bae;Shin Joong Rin;Chae Myung Suk
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.666-670
    • /
    • 2004
  • This paper presents a new approach for determining an accurate incentive levels of Direct Load Control (DLC) program using sequential Monte Carlo Simulation (MCS) techniques. The economic analysis of DLC resources needs to identify the hourly-by-hourly expected energy-not-served resulting from the random outage characteristics of generators as well as to reflect the availability and duration of DLC resources, which results the computational explosion. Therefore, the conventional methods are based on the scenario approaches to reduce the computation time as well as to avoid the complexity of economic studies. In this paper, we have developed a new technique based on the sequential MCS to evaluate the required expected load control amount in each hour and to decide the incentive level satisfying the economic constraints. And also the proposed approach has been considered multi-state as well as two-state of the generating units. In addition, we have applied the variance reduction technique to enhance the efficiency of the simulation. To show the efficiency and effectiveness of the suggested method the numerical studies have been performed for the modified IEEE reliability test system.

  • PDF

A Study on the Wheelchair Storage System Mounted on the Trunk of the Sedan Passenger Car (세단 승용차량 트렁크용 휠체어 수납 시스템에 관한 연구)

  • Lim, Gu;Kim, Young Jae;Kim, Yeoun Ok;Yang, Soon Yong
    • Journal of Drive and Control
    • /
    • v.16 no.3
    • /
    • pp.8-15
    • /
    • 2019
  • Wheelchair users experience difficulty when using transportation. This is because wheelchair users must use transportation means together with wheelchairs. Therefore, in this paper, we developed a wheelchair storage system for passenger's car trunk. The mechanism is designed to allow a wheelchair and the device to be housed simultaneously in the narrow space of the trunk of the sedan passenger car. Additionally, this wheelchair storage system has implemented an initial load reduction mechanism that can mechanically reduce the initial load. This wheelchair storage system verified the system's operability through the production of the prototype. This system was actually installed in the trunk of the sedan passenger's car to verify the storage process. The operation and storage process of the wheelchair storage system was been perfectly verified. This wheelchair storage system will help a lot of self-driver or an assistant (female or elderly) who use wheelchairs.

Effect of Curcuma xanthorrhiza Gel on Methicillin-Resistant Staphylococcus aureus-Infected Second-Degree Burn Wound in Rats

  • Kesumayadi, Irfan;Almas, Ayyasi Izaz;Rambe, Ilham Nur Hakim;Hapsari, Rebriarina
    • Natural Product Sciences
    • /
    • v.27 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • Methicillin-resistant Staphylococcus aureus (MRSA) infection often complicates burn wounds. Mupirocin is the antibiotic of choice for superficial MRSA infection, and its resistance is on the rise due to its frequent and widespread use. This study aimed to develop and evaluate Curcuma xanthorriza extract (CXE)-containing gel as a topical agent against MRSA-infected second-degree burn wound in rats. CXE was obtained using maceration with 96% ethanol. Xanthorrhizol level, antibacterial, and antioxidant activity were evaluated using a standardized method. In vivo, the wound's healing and bacterial load were evaluated every three days, whereas the histopathology of the wound was examined on day 12 of treatment. One-Way ANOVA and Kruskal-Wallis test were used to analyze the data. In this study, 27.0% and 7.10% of the obtained CXE were xanthorrhizol and curcumin, respectively. Additionally, an IC50 of 64.27 ppm was shown in antioxidant activity measurement, and MIC against MRSA was 5 mg/ml. Treatment with CXE-containing gels showed a significant reduction in bacterial load and proliferation of connective tissue in a dose-dependent manner. In conclusion, CXE-containing gel showed a greater reduction of bacterial load and more advanced wound healing phase than mupirocin.

Design of a Prototype Jacket for Upper Extremity Load Reduction (상지 부하 감소를 위한 기능성 상의 프로토타입 디자인)

  • Park, Sunhee;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.4
    • /
    • pp.613-623
    • /
    • 2022
  • This study developed a functional prototype jacket designed to reduce loads on the upper extremities of workers performing repetitive motions in the same posture for extended periods of time. Dynamic taping lines were applied to the upper extremities, and three dimensional (3D) supporters were inserted in the abdomen and back waist areas corresponding to the core muscles. Clothing pressure on the upper-extremity dynamic taping lines was set to two levels (proto P1 and proto P2), and the 3D supporters were designed in three types (proto FW, proto FW/BW, proto FW/BW/BBX). According to the subjective pressure perceived on each part of the upper extremities, the level proto P1 pressure was preferred. The proto FW/BW/BBX 3D supporter was rated as excellent, and the perceived pressure was ranked as satisfactory. The prototype jacket performed upper-extremity load reduction when the upper-extremity clothing-pressure level was set to 1.8 kPa, 2.1 kPa, and 2.4 kPa on the upper arm, forearm, and wrist regions, respectively, and when 3D supporters were installed in the abdomen and back of the waist with the addition of a back band.

A Study on the Performance of Blind type Double-Skin Facade System with PV modules (PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구)

  • Jo, Hye-Jin;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

The Consumer Rationality Assumption in Incentive Based Demand Response Program via Reduction Bidding

  • Babar, Muhammad;Imthias Ahamed, T.P.;Alammar, Essam A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.64-74
    • /
    • 2015
  • Because of the burgeoning demand of the energy, the countries are finding sustainable solutions for these emerging challenges. Demand Side Management is playing a significant role in managing the demand with an aim to support the electrical grid during the peak hours. However, advancement in controls and communication technologies, the aggregators are appearing as a third party entity in implementing demand response program. In this paper, a detailed mathematical framework is discussed in which the aggregator acts as an energy service provider between the utility and the consumers, and facilitate the consumers to actively participate in demand side management by introducing the new concept of demand reduction bidding (DRB) under constrained direct load control. Paper also presented an algorithm for the proposed framework and demonstrated the efficacy of the algorithm by considering few case studies and concluded with simulation results and discussions.