• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.037 seconds

Design investigation of the stress reduction of bolted joint connection components in a large wind turbine blade (대형 풍력발전기 블레이드의 볼트체결부 응력감소를 위한 설계연구)

  • Kwang Tae Ha;June Hur;Jae-Ho Jeong
    • Journal of Wind Energy
    • /
    • v.13 no.4
    • /
    • pp.42-49
    • /
    • 2022
  • Today, the power capacity of a wind turbine and the size of a blade is increasing to capture more wind resources, reduce the number of wind turbines on a wind farm, and reduce the cost of energy. As the blade size becomes larger, attention is being paid to the structural integrity of the blade root connection due to the heavy gravitational load effect and increased aerodynamic loads on the large blade, which could cause catastrophic failure of the blade. Therefore, the secure bolted joint connection of the blade to the hub is very important. In this paper, attention was given to the stress concentration factor (SCF) at the first thread between the M42 bolt and nut. The effect of various design parameters on the stress concentration factor was investigated, which included nut type, nut height, and reduced shank bolt. From a close design investigation of the numerical results, it turned out that the use of a reduced shank bolt resulted in the largest reduction of the stress concentration factor by 40 %, and the round nut type also reduced the SCF by 10 %, which will be beneficial to large wind turbine blades over 100 meters.

Load/Unload Dynamics of Slider on Ramp for Various Ramp Shape (램프 형상에 대한 램프 상의 로드/언로드 동특성 해석)

  • Lee, Yong-Hyun;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.467-472
    • /
    • 2005
  • Load/Unload(L/UL) technology includes the benefits, that is, increased areal density, reduced power consumption and improved shock resistance contrary to contact start stop(CSS). It has been widely used in portable hard disk drive and will become the key technology for developing the small form factor hard disk drive. The main objectives of L/UL are no slider disk contact or no media damage. For realizing those, we must consider many design parameters in L/UL systems. In this paper, we focus on the effect of the ramp profile. We can find out the lateral velocities in L/UL process through experiments and simulations for force of voice coil motor and friction force on ramp. And then, we will gain the optimal design of ramp slope to maintain the minimum clearance of suspension dimple and slider with FE model. In special, after finding the point at which air bearing breaks and designing the ramp, we will identify the results for improving unload performance.

  • PDF

A Study on the Improvement of the Arithmetic for Emergency Generator Capacity (비상발전기용량 산정식 개선에 관한 연구)

  • Lee, Jong-Hyuk;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1517-1522
    • /
    • 2018
  • This paper describes the improvement of the arithmetic for emergency generator capacity. This formula which calculates emergency generator is dependent on the Korean Design Standard of building electrical equipment issued by the Ministry of Land, Infrastructure and Transport, and the technical data related to the generator. when appling the formula, the capacity of the generator is insufficient at the starting conditions of the load facility. In case of emergency, the generator is not operated normally. $PG_2$ of the formula ($PG_1$, $PG_2$, $PG_3$) applied in determining the capacity of the emergency generator is selected by calculating the capacity of the generator based on only biggest one motor among the load equipment and $PG_3$ may not be able to start the generator normally in case of emergency because there is an error such that the power factor is applied at the last start of the motor having the maximum capacity of the load. We analyze the problem of capacity calculation of emergency generators used for general purposes. As a consequence, the improved formulas have been presented for safety of electrical installation.

MPPT of photovoltaic system with duty ratio of DC-DC converter considered load (부하를 고려한 DC-DC 컨버터의 듀티비에 따른 태양광 발전 시스템의 최대전력점 추적)

  • Jun, Young-Sun;Ko, Jae-Sub;Choi, Jung-Sik;Jung, Chul-Ho;Kim, Do-Yeon;Jung, Byung-Jin;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.407-410
    • /
    • 2008
  • This paper presents a maximum power point tracking(MPPT) of photovoltaic system with duty ratio of DC-DC converter considered load. A variation of solar irradiation is most important factor in the MPPT of PV system That is nonlinear, aperiodic and complicated. NN was widely used due to easily solving a complex math problem. The paper consists of solar radiation source, DC-DC converter, DC motor and load(cf, pump). NN algorithm apply to DC-DC converter through an adaptive control of neural network, calculates converter-duty ratio using an adaptive control of NN. The results of an adaptive control of NN compared with the results of converter-duty ratio which are calculated mathematical modeling and evaluate the proposed algorithm. The experimental data show that an adequacy of the algorithm was established through the compared data.

  • PDF

Analyzing Information Value of Temperature Forecast for the Electricity Demand Forecasts (전력 수요 예측 관련 의사결정에 있어서 기온예보의 정보 가치 분석)

  • Han, Chang-Hee;Lee, Joong-Woo;Lee, Ki-Kwang
    • Korean Management Science Review
    • /
    • v.26 no.1
    • /
    • pp.77-91
    • /
    • 2009
  • It is the most important sucess factor for the electricity generation industry to minimize operations cost of surplus electricity generation through accurate demand forecasts. Temperature forecast is a significant input variable, because power demand is mainly linked to the air temperature. This study estimates the information value of the temperature forecast by analyzing the relationship between electricity load and daily air temperature in Korea. Firstly, several characteristics was analyzed by using a population-weighted temperature index, which was transformed from the daily data of the maximum, minimum and mean temperature for the year of 2005 to 2007. A neural network-based load forecaster was derived on the basis of the temperature index. The neural network then was used to evaluate the performance of load forecasts for various types of temperature forecasts (i.e., persistence forecast and perfect forecast) as well as the actual forecast provided by KMA(Korea Meteorological Administration). Finally, the result of the sensitivity analysis indicates that a $0.1^{\circ}C$ improvement in forecast accuracy is worth about $11 million per year.

Integrated Optimal Design for Suspension to Improve Load/unload Performance (로드/언로드 성능향상을 위한 서스팬션의 구조최적화)

  • Kim Ki-Hoon;Son Suk-Ho;Park Kyoung-Su;Yoon Sang-Joon;Park No-Cheol;Yang Hyun-Seok;Choi Dong-Hoon;Park Young-pil
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.204-209
    • /
    • 2005
  • Load/Unload(L/UL) technology includes the benefits, that is, increased areal density, reduced power consumption and improved shock resistance contrary to contact-start-stop(CSS). It has been widely used in portable hard disk drive and will become the key technology far developing the small form factor hard disk drive. The main object of L/UL is no slider-disk contact or no media damage. For realizing those, we must consider many design parameters in L/UL system. In this paper, we focus on lift-off force. The 'lift-off' force, defined as the minimum air bearing force, is another very important indicator of unloading performance. A large amplitude of lift-off force increases the ramp force, the unloading time, the slider oscillation and contact-possibility. To minimize 'lift-off' force we optimizes the slider and suspension using the integrated optimization frame, which automatically integrates the analysis with the optimization and effectively implements the repetitive works between them. In particular, this study is carried out the optimal design considering the process of modes tracking through the entire optimization processes. As a result, we yield the equation which can easily find a lift-off force and structural optimization for suspension.

  • PDF

Load/unload Dynamics of Slider on Ramp for Various Ramp Shapes (램프 형상에 대한 램프 상의 로드/언로드 동특성 해석)

  • Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil;Lee, Yong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1248-1254
    • /
    • 2005
  • L/UL(Load/unload) mechanism has been widely used in SFF(Small form factor) HDD because L/UL technology has many advantages such as an increase of areal density, reduction of power consumption and improvement of shock resistance. In this system, the most important design goal is no slider-disk contact and fast air-hearing breaking during L/UL process. To do so, we should consider many design parameters related to L/UL system. The ramp shape is the most dominant component among parameters which dramatically affect the L/UL performance. This paper makes an advanced ramp model using ANSYS/LS-DYNA. Through this FE model, this paper investigates the effect of initial ramp slope and location of air-bearing breaking. From the experiment for three different ramps, we also verify that experimental results agree with simulation results. We conclude that the ramp design should have small ramp slope at the moment which a suspension tap contacts with ramp and large ramp slope after air-bearing breaking in order to improve L/UL Performance.

Instantaneous Control of a Single-phase PWM Converter Considering the Voltage Ripple Estimate (전압 리플 추정을 고려한 단산 PWM 컨버터의 순시치 제어)

  • 김만기;이우철;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.27-33
    • /
    • 1997
  • In this paper, instantaneous controller of a single-phase PWM converter is realized using DSP. The stable PI gain of the input current and the DC link voltage control system is designed. The DC link voltage control system can be designed in continuous-time domain. But as for the input current control system, the descretizing effect cannot be ignored so it must be designed in descrete-time domain considering the calculation time. The capacitance estimating algorithm which can be acquired through the ripple voltage is proposed. By this algorithm the DC link capacitance can be estimated even under the transient state. Experimental results show the input power factor of 99.1% and the voltage variation rate of $\pm$5% according to the load variation.

  • PDF

DC Link Currents in Frequency Domain for Three-Phase AC/DC/AC PWM Converters

  • Park Young-Wook;Lee Dong-Choon;Seok Jul-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.169-173
    • /
    • 2001
  • In this paper, dc link ripple currents for three-phase ac/dc/ac PWM converters are ana lysed in a frequency domain. The expression of the harmonic currents is developed by using switching functions and exponential Fourier series expansion. The dc link ripple currents with regard to power factor and modulation index are investigated. In addition, the effect of the displacement angle between the switching periods of line-side converters and load-side inverters on the dc link ripple current is studied. The result of the dc link current analysis is helpful in specifying the dc link capacitor size and its lifetime estimation.

  • PDF

Parallel processing of an active filter and a UPS (능동필터 겸용 무정전 전원장치)

  • Kang, Yu-Ri;Kim, Won-Ho;Kim, Jong-Soo;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.550-552
    • /
    • 1994
  • Recently, various activ filters such as current type and voltage type have been proposed to suppress harmonics caused by nonlinear load due to the use of semiconductor switching devices. At the early stage, active filters are used only to suppress harmonics. However, it has been proposed that they offer more functions such as voltage regulations, improvements of power factor and 3 phase unbalance. This study presents a combined function of active filter and a UPSs with one power processing stage.

  • PDF