• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.028 seconds

A Study on the X-Ray Fractography of Turbine Blade under Fatigue Load (피로하중을 받는 터빈 블레이드의 X선 프랙토그래픽에 관한 연구)

  • Hong, Soon-Hyeok;Lee, Dong-Woo;Cho, Seok-Swoo;Joo, Won-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.2
    • /
    • pp.65-71
    • /
    • 2002
  • Turbine blade is subject to cyclic bending force by steam pressure. Stress analysis by fractography is already established technology as means far seeking cause of fracture and has been widely employed. In the X-ray frctography, plastic deformation and residual stress near the fracture surface can be determined and information of internal structure of material can be obtained. Therefore, to find a fracture mechanism of torsion-mounted blade in nuclear power plant, based on the information from the fracture surface obtained by fatigue test, the correlation of X-ray parameter and fracture mechanics parameter was determined and then the stress intensity factor to actual broken turbine blade was predicted.

Performance Prediction of Small Hydropower Plant through Analyzing Rainfall Data (강우자료 분석에 의한 소수력 발전소의 성능예측)

  • Lee, Chul-Hyung;Park, Wan-Soon;Shin, Dong-Ryul;Chung, Hun-Saeng
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.81-91
    • /
    • 1989
  • This study represents the method to predict the flow duration curve and primary design specifications of small hydropower plant at hydropower site through analyzing the monthly rainfall data. Weibull distribution was selected to characterize the rainfall data and Thiessen method was used to calculate monthly average flowrate at site. Application of these results, primary design specifications such as design flowrate, annual average load factor and utility factor, annual average hydropower density and annual electric energy production were estimated and discussed for surveyed site located in Daigi-ri, Kangwon province. And performance characteristic model of small hydro-power plant was applied to estimate these specifications.

  • PDF

A Study of the Partial Circulating Current Type Cycloconverter with a Resonant Circuit for Induction Heating (공진회로(共振回路)를 이용한 유도가열용(誘導加熱用) 부분순환전류형(部分循環電流形) 사이크로콘버터에 관한 연구(硏究))

  • Kim, Hyun-Jung;Cho, Kyu-Min;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1002-1004
    • /
    • 1992
  • This paper presents a study of the partial circulating current type cycloconverter with a resonant circuit for induction heating. A method of input power factor improvement is proposed. Since the circulating currents flow through the circulating current reactors, the out-put currents are continuous and sinusoid. The proposed cycloconverter can keep the displacement factor at 1.0 by PWM control method regardless of load. The control functions are derived, the operational principles are described and the simulation and experimental results are presented.

  • PDF

Online Load Estimation Method of High Frequency Induction Heat System (고주파 유도가열 장치의 실시간 부하예측 기법에 관한 연구)

  • Park, Tae-Joon;Kim, Tae-Won;Lee, Seung-Hee;Lee, Jin-Hee;Han, Mu-Ho;Lee, Hwang-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.123-124
    • /
    • 2010
  • 본 논문은 고주파 유도가열 장치의 실시간 부하 예측 기법을 제안한다. 인버터 출력전압과 콘덴서 양단전압을 센싱하여 adaptive parameter estimation 기법을 이용하여 피가열체인 부하의 등가저항과 인덕턴스를 구한다. 제안된 방법을 이용하여 부하 발열량과 콘덴서 뱅크의 Q factor를 실시간 예측할 수 있다. 콘덴서 뱅크의 Q factor를 통해 부하 부담률을 알 수 있으므로 뱅크의 파손 등의 사고를 미연에 방지 할 수 있게 한다. 본 논문에서 제안한 알고리즘의 타당성을 시뮬레이션을 통해 확인하였고 모의실험장치에 적용하여 실험을 통해 검증하였다.

  • PDF

Hull Form Development for an AFRAMAX Tanker with a Composite Stern Frameline Concept

  • Kim, Ho-chung;Lee, Chun-ju;Kim, Su-hyung
    • Selected Papers of The Society of Naval Architects of Korea
    • /
    • v.1 no.1
    • /
    • pp.65-75
    • /
    • 1993
  • Hull form development for an AFRAMAX tanker characterized by the form parameters of $C_B\simeq0.8$, $L/B\simeq5.5$, $B/T\simeq3.5$, han been carried out by the application of ‘Composite Stern Frameline Concept’. The viscous resistance of the new form was much smaller than that of the conventional form. Form factor of the new form was only 0.18 compared to 0.30 for the conventional hull form, Nevertheless the propulsive efficiency was slightly lower and thus the required propulsion power was smaller by 5~6% at both full load and ballast condition. In addition, it is confirmed that introduction of the form factor method such as ITTC’78 method is highly advisable because there is a great risk of the underperdicting full scale resistance of the hull form whose form the extrapolation of moel resistance to full scale is to be based on Froude method with the correlation allowances usually applied to conventional hull forms.

  • PDF

HPA(Human Powered Aircraft) Material Selection and Structural Design (인력비행기의 소재선정 및 구조설계)

  • Yun, Sungchan;Hu, Hyenoo;You, Saerom;Lee, Jaehong;Kim, Dooman;Oh, Janggeun;Lee, Heewoo
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.1
    • /
    • pp.42-46
    • /
    • 2009
  • The 1st development of "Human Powered Aircraft(HPA)" in Korea has been conducting by KAFA(Korea Air Force Academy) from Aug. 2008 to now. HPA is an aircraft powered by directly human energy. The thrust provided by the human power may be the only source and that is weak. Therefore, light weight and strong structure is first requirement. In this paper, treating a basic conceptual design of HPA and material property and material choice for HPA. Also analysing the structure and checking the safety of HPA.

  • PDF

Analysis of Characteristic for Electric Leakage Component at Stable Size (축사 규모별 누전성분 특성 분석)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.

A Study on the New PWM Control Method of the Cycloconverter with a Resonant Circuit for Induction Heating (공진회로를 이용한 유도가열용 사이크로콘버터의 새로운 PWM 제어법에 관한 연구)

  • Kim, Hyun-Jung;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.797-799
    • /
    • 1993
  • In this paper, we propose a new PWM control method of cycloconverter with a resonant circuit for induction heating. The proposed new PWM control method determines the switching duty ratio compared the integrated value of load current with the reference value of input current on sampling interval. By the Proposed method, the displacement factor becomes 1.0 and the input current waveforms become sinusoid which is nearly 1.0 in terms of the input power factor. To confirm the validity of the proposed method, the simulations and experiments are carried out.

  • PDF

Economic Analysis of High-Efficiency Production Facilities using Capital Recovery Factor (자본회수계수를 고려한 고효율 생산설비의 경제성분석)

  • Park, Hyung-Joon;Chung, Chcn-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.117-123
    • /
    • 2007
  • This paper is about the economic analysis of the replacement of electric facilities in the production facilities. As the interest of energy is increasing, the efficiency of facilities become more important. So, in this paper, we diagnosed facilities, especially electric motors, in the plant and calculated the operating efficiency, power loss with the load factor. And when we replace these facilities into high-efficiency motors, we also calculated new energy efficiency, energy loss and economic analysis through capital recovery factor. As a result, we economically proved that using high-efficiency motor is more beneficial than using non-high-efficiency motors in the model process.

A study on Automatic field Test Equipment with improved maintenance and environmental reliability

  • Lee, Seok-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, I purpose one of the development methods for portable Automatic field Test Equipment(ATE) with VME form factor. Almost portable ATE have not used to standards form factor and they are connected by mechanical non-rigid general connectors and wire harnesses among the components. Furthermore, it is hard to reuse developed board. So, it decreases to reusability of developed board and it is hard to maintenance of ATE. Even those things have weakness for vibration and drop test especially in portable ATE. The XK9A1 ATE using VME form factor has environmental reliability through vibration, drop, temperature test. It consists of 5 developed board called the control board, the wire & wireless communication board, the power supply board, the load board and the mother board. It is connected by two wire harnesses between mother board and extern circular connectors. The control board send the data and address to other board though each 16-bit data and 20-bit address line. You can develop the function board what you want to using those data & address line when it comes to needing other function board.