• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.03 seconds

A SVPWM for the Small Fluctuation of Neutral Point Current in Three-level Inverter (중성점 전류 리플을 고려한 3-레벨 인버터의 공간 벡터 펄스폭 변조 기법)

  • 김래영;이요한;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.33-37
    • /
    • 1998
  • For the high power variable speed applications, the DCTLI(diode clamped three-level inverter) have been widely used. This paper describes the analysis of the neutral point current of the DCTLI and the improved space vector-based PWM strategy considering the switching frequency of power devices, that minimizes the fluctuation of the neutral point current in spite of high modulation index region and low power factor. It contributes to decrease the capacitance of dc-link capacitor bank and to increase the neutral point voltage controllable region. Especially, even if second (or even) order harmonic is induced in load current (at this situation, is was investigated that the general control method can not suppress the neutral point voltage variation), this PWM can provide effective control method to suppress the neutral point voltage variation. Various simulation results by means of Matlab/Simulation are presented to verify the proposed PWM.

  • PDF

Ageing Diagnostics in Oil Transformer for Large Capacity due to Test methods (시험방법에 의한 대용량 유입변압기의 열화진단)

  • Sim, Yoon-Tae;Kim, Wang-Gon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.96-99
    • /
    • 2003
  • In this paper, ageing diagnostics in the large capacity oil transformer are investigated. Following items are investigated for the ageing diagnostic in transformer oils (leakage current of sensor, power consumption and temperature of transformer oil). All temperature data are gathered from daily report in the substation. The power consumption of transformer are gathered output report of APIS(Airport Power Information System). Especially, data of sensor leakage current are accumulated from the online diagnostic system for transformer oil. The temperature of transformer oils major change factor was ambient temperature and capacity of power load. The leakage current are change by oil temperature. The leakage current ware not more than 2 [nA] in summer,

  • PDF

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

Harmonic Compensation by A Flywheel System Based on Stator Flux-Oriented Vector Control of WRIM(Wound Rotor Induction Machine) (권선형 유도전동기의 고정자 자속기준 벡터제어에 의한 전원선의 고조파 보상)

  • Kim Yoon-Ho;Cho Yong-Hyun;Park Kyung-Soo;Jeong Yeon-Suk
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.256-259
    • /
    • 2001
  • An increase of pulsed power demand and load variation produce bad effect to power system. This causes power factor decrease. This paper proposes the excitation of the secondary side of wound rotor induction machine as one of harmonic compensation systems. In this paper, a harmonic compensation scheme based on stator flux-oriented vector control is proposed. By using the flux-oriented vector control, a voltage source PWM(Pulse Width Modulation) control scheme can be applied with fast dynamic response time. The designed control scheme is verified through simulation.

  • PDF

A Study on the Minimization of Generation Cost of an Individual Power Generation Considering Available Transfer Capability(ATC) (가용송전용량을 고려한 각 발전회사의 발전비용 최소화 기법 개발에 관한 연구)

  • Jeong, Sung-Won;Gim, Jae-Hveon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.586-591
    • /
    • 2005
  • This paper presents a method of minimizing of generation cost on individual electrical power utility. The method is based on the Economic Dispatch (ED) and linear Available Transfer Capability (ATC). The economic dispatch redistributes the total load to individual units to minimize the generation cost without transmission network constraints. The proposed method is implemented using ATC calculated from Power Transfer Distribution Factor (PTDF) for the transmission network constraints. The performance of the proposed method has been tested for the IEEE-30 bus system. It has also been observed that the results of the proposed method is compared with that of optimal power flow.

Design and Analysis of an Interleaved Boundary Conduction Mode (BCM) Buck PFC Converter

  • Choi, Hangseok
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.641-648
    • /
    • 2014
  • This paper presents the design considerations and analysis for an interleaved boundary conduction mode power factor correction buck converter. A thorough analysis of the harmonic content of the AC line current is presented to examine the allowable voltage gain (K value) for meeting the EN61000-3-2, Class D standard while maximizing efficiency. The results of the harmonic analysis are used to derive the required value of K and therefore the output voltage necessary to meet the class D requirements for a given AC line voltage. The discussed design consideration and harmonic current analysis are verified on a 300W universal line experimental prototype converter with an 80V output. The measured efficiencies remain above 96% down to 20% of the full load. The input current harmonics also meet the IEC61000-3-2 (class D) standard.

New Control Scheme for AC-DC-AC Converter Without DC Link Electrolytic Capacitor (직류링크 전해커패시터 없는 AC-DC-AC 컨버터 제어에 관한 연구)

  • Kim, Joohn-Sheok;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.695-697
    • /
    • 1993
  • In this paper, a novel concept for a static three-phase to three-phase power converter for an AC drive with an unity power factor and reduced harmonics on the utility line is presented. The power circuit consists of two back-to-back connected six-pulse bridges having only a $5{\mu}F$ ceramic capacitor in the DC link. By controlling the active power balance between two bridges, the DC link voltage can be maintained within 20V deviation from the nominal value with the small ceramic capacitor regardless of the load variation even in the unbalanced source condition.

  • PDF

A method to analyze the flyability of airplane trajectories with specified engine power

  • Gilles Labonte;Vincent Roberge;Mohammed Tarbouchi
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.5
    • /
    • pp.473-494
    • /
    • 2023
  • This article introduces a formalism for the analysis of airplane trajectories on which the motion is determined by specifying the power of the engines. It explains a procedure to solve the equations of motion to obtain the value of the relevant flight parameters. It then enumerates the constraints that the dynamical abilities of the airplane impose on the amount of fuel used, the speed, the load factor, the lift coefficient, the positivity and upper boundedness of the power available. Examples of analysis are provided to illustrate the method proposed, with rectilinear and circular trajectories. Two very different types of airplanes are used in the examples: a Silver Fox-like small UAV and a common Cessna 182 Skylane.

A Study on the Deformation of the Moving Pressure Plate in a Balanced Type Vane Pump (압력 평형형 베인 펌프의 가동 압력판 변형에 관한 연구)

  • 한동철;조명래;박신희;최상현
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.277-285
    • /
    • 1998
  • This paper presents the deformation characteristics of the moving pressure plate in a balanced type vane pump that widely used automotive power steering systems. Moving pressure plate can control the clearance between rotor and plate in accordance with load pressure variation; it always guarantees that pump to have optimal volumetric efficiency. In this paper, firstly, we calculate the acting force on the pressure plate, which is used to determine the angular position and load condition for analyzing the deformation of pressure plate. Secondary, finite element method is used for the deformation analysis. As results of acting force analysis, it is found that maximum difference of forces occurs at angular position 28$\circ$ from the small arc center of cam ring and load pressure is a dominant factor to affect acting force variation. The deformation of pressure plate increases as load pressure increases. At high load pressure, the deformation of pressure plate becomes larger than the initial clearance between rotor and plate. Therefore, it is required to design the plate for controlling the deformation.

  • PDF

Electric power consumption predictive modeling of an electric propulsion ship considering the marine environment

  • Lim, Chae-og;Park, Byeong-cheol;Lee, Jae-chul;Kim, Eun Soo;Shin, Sung-chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.2
    • /
    • pp.765-781
    • /
    • 2019
  • This study predicts the power consumption of an Electric Propulsion Ship (EPS) in marine environment. The EPS is driven by a propeller rotated by a propulsion motor, and the power consumption of the propeller changes by the marine environment. The propulsion motor consumes the highest percentage of the ships' total power. Therefore, it is necessary to predict the power consumption and determine the power generation capacity and the propeller capacity to design an efficient EPS. This study constructs a power estimation simulator for EPS by using a ship motion model including marine environment and an electric power consumption model. The usage factor that represents the relationship between power consumption and propulsion is applied to the simulator for power prediction. Four marine environment scenarios are set up and the power consumed by the propeller to maintain a constant ship speed according to the marine environment is predicted in each scenario.