• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.032 seconds

Totem-pole Bridgeless Boost PFC Converter Based on GaN FETs (GaN FET을 이용한 토템폴 구조의 브리지리스 부스트 PFC 컨버터)

  • Jang, Paul;Kang, Sang-Woo;Cho, Bo-Hyung;Kim, Jin-Han;Seo, Han-Sol;Park, Hyun-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.214-222
    • /
    • 2015
  • The superiority of gallium nitride FET (GaN FET) over silicon MOSFET is examined in this paper. One of the outstanding features of GaN FET is low reverse-recovery charge, which enables continuous conduction mode operation of totem-pole bridgeless boost power factor correction (PFC) circuit. Among many bridgeless topologies, totem-pole bridgeless shows high efficiency and low conducted electromagnetic interference performance, with low cost and simple control scheme. The operation principle, control scheme, and circuit implementation of the proposed topology are provided. The converter is driven in two-module interleaved topology to operate at a power level of 5.5 kW, whereas phase-shedding control is adopted for light load efficiency improvement. Negative bias circuit is used in gate drivers to avoid the shoot-through induced by high speed switching. The superiority of GaN FET is verified by constructing a 5.5 kW prototype of two-module interleaved totem-pole bridgeless boost PFC converter. The experiment results show the highest efficiency of 98.7% at 1.6 kW load and an efficiency of 97.7% at the rated load.

Power Factor Improvement of Distribution System with EV Chargers based on SMC Method for SVC

  • Farkoush, Saeid Gholami;Kim, Chang-Hwan;Jung, Ho-Chul;Lee, Sanghyuk;Theera-Umpon, Nipon;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1340-1347
    • /
    • 2017
  • Utilization of Electric Vehicles (EVs) have been growing popularity in recent years due to increment in fuel price and lack of natural resources. Random unexpected charging by home EV charger in distribution is predicted in the future. The power quality problems such as fluctuation of power factor in a residential distribution network was explored with random EV chargers. This paper proposes a high-performance nonlinear sliding mode controller (SMC) for an EV charging system to compensate voltage distortions and to enhance the power factor against the unbalanced EV chargers. For the verification of the proposed scheme, MATLAB-Simulink simulations are performed on 22.9-kV grid. The results show that the proposed scheme can improve the power factor of a smart grid due to the EV chargers on the grid.

Novel Single-Stage Power Factor Correction AC/DC Converter with Low DC Link Voltage using New Magnetic Feedback Technique (새로운 마그네틱 피드백 기법을 이용하여 낮은 링크 전압을 갖는 새로운 단일 전력단 역률 개선 AC/DC 컨버터)

  • Choi E. S.;Yoon H. K.;Kim C. E.;Moon G. W.;Youn M. J.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.528-532
    • /
    • 2004
  • Novel single-stage power factor correction AC/DC converter with low DC link voltage using new magnetic feedback technique is proposed in this paper. The Proposed converter has high power factor, tight output voltage regulation and low link capacitor voltage less than 450V for all the load range through the universal input line. This converter has also no dead-zone in the input current, which is seen in the conventional converter using the previous magnetic feedback technique. In this paper, the analysis of operations and features of the proposed converter is provided, and the experimental results of 90W-prototype shows the low harmonic distortions satisfied with EN 61000-3-2 Class D, high power factor and low link voltage less than 450V.

  • PDF

CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump (지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축)

  • Lee, Geon-Woo;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.349-354
    • /
    • 2008
  • August 2008, Our country was announced the Energy Vision 2030 for strengthening response capability climate change by the greenhouse effect, 'Stable supply of energy' and 'Efficient systems'. According to the report, Our country is the world's top 10 is a country that consumes a lot of energy. and more than 97% of the energy because it is dependent on foreign imports, The importance of NRE(New and Renewable Energy) is rising significantly, This paper was applied geothermal heat pump it one kind of the renewable energy equipment, in General buildings, and analyzed the effect of the installation. Thus, to improve the load factor of the Electric power system was proposed, and As a result, can be expected the energy cost savings and the reduction of greenhouse gases, through Economic electric power supply.

  • PDF

Analysis and Control of a Modular MV-to-LV Rectifier based on a Cascaded Multilevel Converter

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Khakbazan-Fard, Mahboubeh;Schanen, Jean-Luc
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.133-145
    • /
    • 2009
  • In this paper a modular high performance MV-to-LV rectifier based on a cascaded H-bridge rectifier is presented. The proposed rectifier can directly connect to the medium voltage levels and provide a low-voltage and highly-stable DC interface with the consumer applications. The input stage eliminates the necessity for heavy and bulky step-down transformers. It corrects the input power factor and maintains the voltage balance among the individual DC buses. The second stage includes the high frequency parallel-output DC/DC converters which prepares the galvanic isolation, regulates the output voltage, and attenuates the low frequency voltage ripple ($2f_{line}$) generated by the first stage. The parallel-output converters can work in interleaving mode and the active load-current sharing technique is utilized to balance the load power among them. The detailed analysis for modeling and control of the proposed structure is presented. The validity and performance of the proposed topology is verified by simulation and experimental results.

The PWM Controlled Cycloconverter with a Resonant Circuit for a Induction Heating (LC공진회로를 이용한 유도가열용 PWM 제어형 사이클로콘버터)

  • Kim, Young-Seok;Kim, Hyun-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.214-218
    • /
    • 1991
  • This paper presents a PWM controlled cycloconverter with a DC resonant circuit for Induction heating. This cycloconverter converts commercial frequency power to high frequency power directly. So conversion efficiency improved. Controlling a input reactive power regardless of load power, it has sinusoidal input current waveforms as well as a input. displacement factor at 1.

  • PDF

A Study on the PWM Controlled Cycloconverter with a Resonant Circuit for Induction Heating (공진회로를 이용한 유도가열용 PWM 제어형 사이크로콘버터에 관한 연구)

  • Kim, Young-Seok;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.283-286
    • /
    • 1990
  • This paper presents a PWM controlled cycloconverter with a LC resonant circuit for induction heating. This cycloconverter converts commercial frequency power to high frequency power directly. So conversion efficiency improved. Controlling a input reactive power regardless of load power, it has sinusoidal input current waveforms as well as a input displacement factor at 1.

  • PDF

A Study on the Power Supply for Endura Electrodeless Lamp (엔두라 무전극 램프용 전원장치 연구)

  • 한수빈;박석인;정봉만;김규덕;이선근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.15-18
    • /
    • 2002
  • Power supply technique for electrodeless lamps, especially Endura of Osram, is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Less performance but sufficient to predict future success compared to Osram's one is verified as a result of experiment of the prototype.

  • PDF

A Study on the Power Supply for Electrodeless Lamp (무전극 형광등용 전원)

  • Han, Soo-Bin;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.13-16
    • /
    • 2004
  • Power supply technique for electrodeless lamps is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Experiment and performance comparison for both Endura md QL are performed and further study to commercialization are discussed.

  • PDF

A Study on the Compensation of Reactive Power by III, IV Quadrant Phase Controlled Rectifier (III, IV상한 위상제어정류기에 의한 무효전력 보상에 관한 연구)

  • 정연택;서영수;이사영
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.3
    • /
    • pp.76-83
    • /
    • 1983
  • This paper describes the method of operating the phase controlled rectifier by controlling the firing angle in III, IV quadrant to absorb the lrading reactive power and of improving the waveform of ac current by driving dual converter. The system is intended to compensate the reactive power for any lagging load. Also, by the above method this paper enables us to improve the power factor and waveform referred to the source current and the dc output voltage in the converter.

  • PDF