• Title/Summary/Keyword: Load point

Search Result 2,605, Processing Time 0.027 seconds

Large deflection of simple variable-arc-length beam subjected to a point load

  • Chucheepsakul, S.;Thepphitak, G.;Wang, C.M.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.1
    • /
    • pp.49-59
    • /
    • 1996
  • This paper considers large deflection problem of a simply supported beam with variable are length subjected to a point load. The beam has one of its ends hinged and at a fixed distance from this end propped by a frictionless support over which the beam can slide freely. This highly nonlinear flexural problem is solved by elliptic-integral method and shooting-optimization technique, thereby providing independent checks on the new solutions. Because the beam can slide freely over the frictionless support, there is a maximum or critical load which the beam can carry and it is dependent on the position of the load. Interestingly, two possible equilibrium configurations can be obtained for a given load magnitude which is less than the critical value. The maximum arc-length was found to be equal to about 2.19 times the fixed distance between the supports and this value is independent of the load position.

An Experimental Study on the Structural Characteristics of Reinforced Concrete Beams Containing Oyster Shells (굴패각을 사용한 철근콘크리트 보의 특성에 관한 실험적 연구)

  • Lee, Sang-cheol;Woo, Song-gyu;An, Yong-deok;Jun, Hak-su;Koo, Hae-shik
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.135-142
    • /
    • 2007
  • This is an experimental study on the structural characteristics of reinforced concrete beams using of the oyster shells as a substitute fine aggregate of concrete. In this study, the main factors consist of the grain sizes and the percentage of substitution of oyster shells to fine aggregate in the equal water cement ratio. The results of the study showed as followed. The initial load value of them represented similar constant within 10% of the maximum load value in each test beam. But the maximum load value and the ultimate load value decreased with increased grain size and the rate of substitution. As the grain size of oyster shells became smaller, the load values of them were somewhat higher. The deflection among deformation properties of reinforced concrete beams with oyster shells represented typical curves like that of normal reinforced concrete. In the deformation of steel and concrete, the deformation was proportionated to the load till yield point and from yield point until approaching the ultimate load point. One type was typical curve of the load and the deformation and the other type irregularly was changed to very small deformation for the load increase centering around load axis. After the analyzing structural behaviors and the properties of reinforced concrete test beams with oyster shells, the most excellent grain size of oyster shells represented 1.0mm and less or 5.0mm and less with taking uniformly, and the percentage of practicable substitution of them to fine aggregate was about 30%.

Investigation of the model scale and particle size effects on the point load index and tensile strength of concrete using particle flow code

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Hedayat, Ahmadreza;Marji, Mohammad Fatehi
    • Structural Engineering and Mechanics
    • /
    • v.66 no.4
    • /
    • pp.445-452
    • /
    • 2018
  • In this paper the effects of particle size and model scale of concrete have been investigated on point load index, tensile strength, and the failure processes using a PFC2D numerical modeling study. Circular and semi-circular specimens of concrete were numerically modeled using the same particle size, 0.27 mm, but with different model diameters of 75 mm, 54 mm, 25 mm, and 12.5 mm. In addition, circular and semi-circular models with the diameter of 27 mm and particle sizes of 0.27 mm, 0.47 mm, 0.67 mm, 0.87 mm, 1.07 mm, and 1.27 mm were simulated to determine whether they can match the experimental observations from point load and Brazilian tests. The numerical modeling results show that the failure patterns are influenced by the model scale and particle size, as expected. Both Is(50) and Brazilian tensile strength values increased as the model diameter and particle sizes increased. The ratio of Brazilian tensile strength to Is(50) showed a reduction as the particle size increased but did not change with the increase in the model scale.

A study on the Maximum Power Point Tracking Control System of Wind Power Generation (풍력발전의 최대전력점 추종제어 방법에 관한 연구)

  • Ko, Seok-Cheol;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking (MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

A study on the Maximum Power Point Tracking Control System of Wind Power Generation (풍력발전의 최대전력점 추종제어 방법에 관한 연구)

  • Ko, Seok-Cheol;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) Is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking(MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

Development of a Depth and Working Load Control System for Tractor Using a Proportional Valve (비례밸브를 이용한 트랙터 경심 및 부하제어시스템 개발)

  • Lee, S.S.;Lee, J.Y.;Mun, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.16-23
    • /
    • 2006
  • Depth and working load control is one of the most important technique in control system for tractor rotary implement automation. Keeping the depth consistent is critical to bring along crops and to improve the efficiency and quality of the following operations. Keeping the load of engine consistent is an essential factor for the efficiency of operation and engine protection of tractor. In this study we investigated the possibility of application of depth and working load control system for tractor using a proportional valve through field tests. Depth control was implemented by the ascent and descent of 3 point linkage for the change of setting depth. There were 4 mm and 5.2 mm control deviations for setting depths of 50mm and 100mm, respectively. Load control was operated appropriately by the ascent and of descent of 3 point link for the change of setting working load. The standard deviations between setting load and engine load were 171 rpm at 1.3 km/h and 164 rpm at 2.3 km/h tractor travel velocity. The results of experiment showed that the characteristics of response was sufficient to be used as the implement depth and working load control system for tractor using proportional valve.

The Study on the Correlation between Unconfined Compressive Strength and Point Load Strength within the Gneiss Complex in Gyunggi Province (경기 동부 지역 편마암복합체내의 일축압축강도와 점하중강도의 상관관계에 관한 연구)

  • Cha, Areum;Song, Joonho;Choi, Hyunseok;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.1
    • /
    • pp.21-26
    • /
    • 2007
  • The strength evaluation of rocks is a very important factor in designing and constructing tunnels or underground excavation. However, it takes a lot of time and endeavor to perform the unconfined compressive strength test for practice and a number of tests are limited. In order to make up for this method, the point load strength test is suggested. Generally, the strength of a rock differs depending on its type and region. However, as people unite the Point Load Strength Indexes of various regions and types to use in practice in many cases, they find difficulty in analogizing the exact strength. The purpose of this study is suggestion of the value in construction site by analizing the relation of both unconfined compressive and point load strength in the Gyeonggi gneiss complex.

  • PDF

A Study on Automatic Compensation for Head Lamps Cut-off Line Under Load Variation (차량 하중 변동에 따른 전조등 컷오프라인 자동 보상에 대한 연구)

  • Kim, Ki-Hyeon;Kim, Jun-Hyeon;Byeon, Dong-Kyu;Lee, Dong-Ik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.92-97
    • /
    • 2011
  • Vehicle lightings are very important for safe driving during night time. Since the eye recovery time after an exposure to oncoming headlights would take after several seconds, the aiming point of vehicle head lamps have to pass safety requirements. Despite the fact that vehicle inclination is variable with vehicle load conditions, the head lamps aiming point is usually fixed at a constant position which is set by car manufacturer. Consequently, vehicle head lamps under varying load conditions often make people in the opposing vehicle uncomfortable, and even worse, can cause an accident. This paper presents an active vehicle lighting mechanism to automatically adjust its aiming point, or cut-off line, in order to compensate the change in vehicle inclination resulting from load variations. The effectiveness of the proposed method is demonstrated through a set of simulations and experiments with a real vehicle.

Improvement of Power Generation of Microbial Fuel Cells using Maximum Power Point Tracking (MPPT) and Automatic Load Control Algorithm (최대전력점추적방법과 외부저항 제어 알고리즘을 이용한 미생물연료 전지의 전력생산 최대화)

  • Song, Young Eun;Kim, Jung Rae
    • KSBB Journal
    • /
    • v.29 no.4
    • /
    • pp.225-231
    • /
    • 2014
  • A microbial fuel cell (MFC) and bioelectrochemical systems are novel bioprocesses which employ exoelectrogenic biofilm on electrode as a biocatalyst for electricity generation and various useful chemical production. Previous reports show that electrogenic biofilms of MFCs are time varying systems and dynamically interactive with the electrically conductive media (carbon paper as terminal electron acceptor). It has been reported that maximum power point tracking (MPPT) method can automatically control load by algorithm so that increase power generation and columbic efficiency. In this study, we developed logic based control strategy for external load resistance by using $LabVIEW^{TM}$ which increases the power production with using flat-plate MFCs and MPPT circuit board. The flat-plate MFCs inoculated with anaerobic digester sludge were stabilized with fixed external resistance from $1000{\Omega}$ to $100{\Omega}$. Automatic load control with MPPT started load from $52{\Omega}$ during 120 hours of operation. MPPT control strategy increased approximately 2.7 times of power production and power density (1.95 mW and $13.02mW/m^3$) compared to the initial values before application of MPPT (0.72 mW and $4.79mW/m^3$).

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.