• Title/Summary/Keyword: Load measurement

Search Result 1,656, Processing Time 0.032 seconds

Field measurement and numerical simulation of excavation damaged zone in a 2000 m-deep cavern

  • Zhang, Yuting;Ding, Xiuli;Huang, Shuling;Qin, Yang;Li, Peng;Li, Yujie
    • Geomechanics and Engineering
    • /
    • v.16 no.4
    • /
    • pp.399-413
    • /
    • 2018
  • This paper addresses the issue of field measurement of excavation damage zone (EDZ) and its numerical simulation method considering both excavation unloading and blasting load effects. Firstly, a 2000 m-deep rock cavern in China is focused. A detailed analysis is conducted on the field measurement data regarding the mechanical response of rock masses subjected to excavation and blasting operation. The extent of EDZ is revealed 3.6 m-4.0 m, accounting for 28.6% of the cavern span, so it is significantly larger than rock caverns at conventional overburden depth. The rock mass mechanical response subjected to excavation and blasting is time-independent. Afterwards, based on findings of the field measurement data, a numerical evaluation method for EDZ determination considering both excavation unloading and blasting load effects is presented. The basic idea and general procedures are illustrated. It features a calibration operation of damage constant, which is defined in an elasto-plastic damage constitutive model, and a regression process of blasting load using field blasting vibration monitoring data. The numerical simulation results are basically consistent with the field measurement results. Further, some issues regarding the blasting loads, applicability of proposed numerical method, and some other factors are discussed. In conclusion, the field measurement data collected from the 2000 m-deep rock cavern and the corresponding findings will broaden the understanding of tunnel behavior subjected to excavation and blasting at great depth. Meanwhile, the presented numerical simulation method for EDZ determination considering both excavation unloading and blasting load effects can be used to evaluate rock caverns with similar characteristics.

Finite Element Analysis of Nonlinear Behavior of a Column Type Sensing Element for Load Cell According to Design Parameters (기둥형 로드셀 감지부의 설계변수에 따른 비선형 거동해석)

  • Lee, Chun-Yeol;Gang, Dae-Im
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.6 s.177
    • /
    • pp.1540-1546
    • /
    • 2000
  • Recently, force measurement systems are commonly used in many industrial fields and the precision of the measurement system is getting more important as the industry needs more precise tools and in struments to make high quality products. However, a high precision force measurement system is hard to make unless we know precisely the causes, quality and quantity of measurement errors in advance. In this work, many possible mechanical causes of measurement errors are reviewed including ratio of length to diameter of sensing part, radius of contact area, radius of bearing part, ratio of material properties and change of boundary conditions. Also, the measurement errors are analyzed by nonlinear finite element method and the nonlinear behavior of the errors are investigated. The results can be used to design force measurement systems and expected to be very useful especially for compact type load cells.

A study on laser technology for measurement of wheel/rail interaction force (차륜/레일 작용력 측정을 위한 레이저기술 연구)

  • Ham Y. S.;Seo J. W.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.674-678
    • /
    • 2003
  • This research is develop the sensing and measurement technology for measure that wheel/rail interaction force to use laser. Investigated existent laser measurement system, and examined transformation by load that action to wheel for achieve research purpose. A proposed to laser measurement system composition plan to analyze existent method that measure wheel/rail interaction force.

  • PDF

Measurement and Analysis for Electric Locomotive Modeling (전기철도 부하모델링을 위한 신형 전기기관차 측정 및 결과분석)

  • Kim Joorak;Han Moonseob;Jang Donguk;Lee Kiwon;Shim Keonbo;Kim Junghoon
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.403-408
    • /
    • 2003
  • This paper presents measurement to develop load model for electric locomotive. Load model is defined as polynomial form and each coefficient is solved by the least square method. Therefore, many data is required for using this method. The measurement is performed on KNR line, from Chongryangri to Donghae. The subject of measurement is voltage, current, active power, reactive power an frequency for EL8100.

  • PDF

Centralized Adaptive Under Frequency Load Shedding Schemes for Smart Grid Using Synchronous Phase Measurement Unit

  • Yang, D.Y.;Cai, G.W.;Jiang, Y.T.;Liu, C.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.446-452
    • /
    • 2013
  • Under frequency load shedding (UFLS) is an effective way to prevent system blackout after a serious disturbance occurs in a power system. A novel centralized adaptive under frequency load shedding (AUFLS) scheme using the synchronous phase measurement unit (PMU) is proposed in this paper. Two main stages are consisted of in the developed technique. In the first stage, the active power deficit is estimated by using the simplest expression of the generator swing equation and static load model since the frequency, voltages and their rate of change can be obtained by means of measurements in real-time from various devices such as phase measurement units. In the second stage, the UFLS schemes are adapted to the estimated magnitude based on the presented model. The effectiveness of the proposed AUFLS scheme is investigated simulating different disturbance in IEEE 10-generator 39-bus New England test system.

The Influence and Treatment Method of Extraneous Deformation & Unstability on the Flexural Toughness of FRC (FRC의 휨인성 평가시 외부변형과 불안정성의 영향 및 처리방안)

  • Kim, Kyoung-Soo;Kim, Nam-Wook;Lim, Jeong-Hwan;Bae, Ju-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.119-128
    • /
    • 2002
  • This study discusses the issues related to the accuracy of deflection measurement and unstable energy in the testing of FRC. Some deflection methods may include large extraneous deformations. A faulty load-deflection curve will be obtained if an unstable deflection measuring system is used, and inaccurate toughness evaluation can result from this faulty curve. Some load-deflection curve of FRC may be attributed to unstable region of the load-deflection curve. If the unstable region is not correctly evaluated toughness indices from the curve would inappropriately represent true indices. In this paper, the discussion will focus on the effects of the deflection measuring system both on the measurement of the load-deflection response of FRC and the evaluation of FRC toughness and the effects of the unstable region and the management method of unstable region on toughness evaluation of FRC. It is observed that ASTM toughness indices which is based on measured deflection at first cracking is influenced significantly by extraneous deformation of deflection measurement. Extraneous deformation in deflection measurement, however result in negligible errors in toughness evaluation if JSCE and JCI definitions are used.

A study on the measurement method of raw laver weight using load cell (로드셀을 이용한 생김 중량측정 방법에 관한 연구)

  • Eun-Bi MIN;Tae-Jong KANG;Eun-A YOON;Ok-Sam KIM;Doo-Jin HWANG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.3
    • /
    • pp.215-220
    • /
    • 2023
  • This study developed and evaluated a load cell-based automatic weighing system for the automated harvesting of laver (Porphyra tenera) in seaweed aquaculture. The current manual harvesting process was compared with the load cell-based automated system, and quantitative measurements of time, distance, and weight were conducted. The results demonstrated that the load cell-based system reduced the unloading time and increased the throughput compared to the manual method. In addition, statistical analysis confirmed that there was no significant difference from the mean in the weight measurement obtained using the load cell-based system. Based on these findings, the load cell-based automatic weighing system holds potential for efficient production and transactions in laver cultivation, contributing to cost reduction and improving the quality of life for aquaculture workers.

Capacity Determination of ESS for Peak Load Shaving Based on the Actual Measurement of Loads in the Substation of Urban Railway (도시철도 실측 부하에 기반한 첨두부하 절감용 ESS 용량 산정)

  • Park, Jong-Young;Jung, Hosung;Kim, Hyungchul;Shin, Seungkwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.860-865
    • /
    • 2014
  • This paper proposes the method for determination of the capacities of ESS (Energy Storage System) and PCS (Power Conditioning System) for the peak load shaving based on the load data in the substation of urban railway. In addition, this paper analyze the actual measurement of loads in the substation of urban railway. The load of a weekday in the substation of urban railway is high around rush hours in the morning and evening, which is different from that of a normal substation. The required capacities of ESS and PCS become larger as the amount of peak load shaving is higher, and are affected from the patterns of daily load in the substation.

A Study on the Application of Under Voltage Load Shedding Scheme in Line Contingency considering Motor Load (모터부하를 고려한 상정사고 발생 시 저전압 부하차단 적용 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.21-26
    • /
    • 2017
  • Failure of high-voltage transmission line, which is responsible for large-scale power transmission, can be reason for system voltage instability. There are many methods to prevent voltage instability like adjustment of equipment, the generator voltage setting, and load shedding. Among them, the load shedding, have a problem of economic loss and cascading effect to power system. Therefore, the execution of load shedding, amount and timing is very important. Conventionally, the load shedding setting is decided by the preformed simulation. Now, it is possible to monitor the power system in real time by the appearance of PMU(Phasor Measurement Unit). By this reason, some of research is performed about decentralized load shedding. The characteristics of the load can impact to amount and timing of decentralized load shedding. Especially, it is necessary to consider the influence of the induction motor loads. This paper review recent topic about under voltage load shedding and compare with decentralized load shedding scheme with conventional load shedding scheme. And simulations show the effectiveness of proposed method in resolving the delayed voltage recovery in the Korean Power System.

Measurement of Pile Load Transfer using Optical Fiber Sensors (광섬유 센서에 의한 말뚝 하중전이 측정)

  • 오정호;이원제;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.397-404
    • /
    • 1999
  • It is essential to measure load transfer mechanism of pile to check the appropriateness of assumptions made for design purpose and to continuously monitor the behavior of pile foundation. Through many attempts to monitor the behavior of super-structure in civil engineering area using several optical fiber sensors have been made, application of optical fiber sensor technology on pile foundation has not been tried up to now. Load transfer of model piles during compression loading was measured by optical fiber sensors and compared with the measurement by strain gauges. Fiber Bragg Grating(FBG) sensor system was used since it has many advantages, such as easy multiplexing, high sensitivity, and simple fabrication. Besides the model pile tests, uniaxial tension test of steel bar and compression tests of mortar specimen were carried out to evaluate the performance of FBG sensors in embedded environments. The shift of refilming wavelength due to the strain in FBG sensor is converted to the strain at sensor location and the dependence between them is 1.28 pm/${\mu}$ strain. FBG sensors embedded in model pile showed a better survivability than strain gauges. Measured results of load transfer by both FBG sensors and strain gauges were similar, but FBG sensors showed a smoother trend than those by strain gauge. Based on the results of model pile test, it was concluded that the use of FBG sensor for strain measurement in pile has a great potential for the analysis of pile load transfer.

  • PDF