• Title/Summary/Keyword: Load frequency control

Search Result 793, Processing Time 0.03 seconds

A Voltage Bus Conditioner for a High Voltage DC Power Distribution System using High Performance Hysteresis Control (고성능 히스테리 제어를 이용한 고전압 DC 전력시스템을 위한 Voltage Bus Conditioner)

  • La, Jae-Du
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.2
    • /
    • pp.90-98
    • /
    • 2007
  • More and All-Electric Aircraft (AEA) carry many loads with varied functions. In particular, there may be large pulsed loads with short duty ratio, which can affect the normal operation of other loads. In this paper, a bi-directional converter with inductive storage is used as a voltage bus conditioner (VBC) to mitigate voltage transients on the bus. In addition, the constant frequency hysteresis control technique for a VBC is presented. A simple and fast prediction of the hysteresis band-width is implemented by the phase-lock loop control, keeping constant switching frequency. This technique offers the excellent dynamic response in load or parameter variation. The control performance is illustrated by simulated results with the SABER package, The proposed hysteresis control results in the shortest and the smallest excursions.

The improvement of control strategy in thermal power plant turbine system by nonlinear analysis (비선형성 해석에 의한 화력발전소 터어빈 제어계통에 관한 연구)

  • ;;Hwang, Jae-Ho;Seo, Jin-Hun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.567-571
    • /
    • 1989
  • This paper describes the improvement of thermal power plant turbine control system by analyzing nonlinear characteristics. The turbine control depends on the frequency variation and boiler condition. The nonlinearity of turbine control is the result of governor/valve properties, steam condition and boiler thermal unbalance. Nonlinear analysis is divided into two; main steam valve position - turbine output anal governor response. Of course, every analysis must be done on considering plant operating condition. In this paper, after analyzing turbine control nonlinearity by numerical method and actual results, the sensitive operating load which corresponds to frequency is proposed, on guarranteed boiler stability. This idea is implemented at Pyung Tack thermal power plant, and the practical results are showed.

  • PDF

Robust PID Controller Design for Speed Control of BLDC Motors (BLDC 모터 속도제어를 위한 견실 PID 제어기 설계)

  • 양승윤;김인수;전완수
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.75-82
    • /
    • 2002
  • In this paper, the robust PID(Proportional-Integral-Derivative) controller was designed for speed control of BLDC motors using the frequency region model matching method. It was designed the robust PID controller satisfying disturbance attenuation and robust tracking performance using an H$\infty$ control method. The robust PID controller gains with the performances of the designed H$\infty$ controller are determined using the model matching method at frequency domain. Consequently, simulation results show that the proposed PID speed controller satisfies load torque disturbance attenuation and robust tracking performance, and this study has usefulness and applicability for the speed control system design of BLDC motors.

Implement of Constant-Frequency-Controled Zero-Voltage-Switching Converter-fed DC Motor Drive for Low Power Loss (직류 전동기의 저손실 구동을 위한 일정 주파수 제어형 영전압 스위칭 변환기의 구현)

  • Ko, Moon-Ju;Park, Jin-Hong;Han, Wan-Ok;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2148-2150
    • /
    • 1998
  • This paper proposes a constant frequency controlled zero voltage switching method that can reduce switching losses caused by emf on inductance in DC motor. The zero voltage switching method is used more than a zero current switching method because of reducing switching losses by capacitance of depletion region of MOSFET. To simplify the controller circuit, we propose constant frequency controlled zero voltage switching method in the paper. The control method is more stable than a variable frequency control method because it can optimize bandwidth of a closed-loop and reactances. Therefore, we construct a constant frequency controlled zero voltage switching converter and improve zero switching losses in high switching frequency. In the process, we can control low-losses in full range on variable voltage and load. We simulate the proposed converter with P-SPICE and compare results obtained through the experiment.

  • PDF

Industrial load forecasting using the fuzzy clustering and wavelet transform analysis

  • Yu, In-Keun
    • Journal of IKEEE
    • /
    • v.4 no.2 s.7
    • /
    • pp.233-240
    • /
    • 2000
  • This paper presents fuzzy clustering and wavelet transform analysis based technique for the industrial hourly load forecasting fur the purpose of peak demand control. Firstly, one year of historical load data were sorted and clustered into several groups using fuzzy clustering and then wavelet transform is adopted using the Biorthogonal mother wavelet in order to forecast the peak load of one hour ahead. The 5-level decomposition of the daily industrial load curve is implemented to consider the weather sensitive component of loads effectively. The wavelet coefficients associated with certain frequency and time localization is adjusted using the conventional multiple regression method and the components are reconstructed to predict the final loads through a five-scale synthesis technique. The outcome of the study clearly indicates that the proposed composite model of fuzzy clustering and wavelet transform approach can be used as an attractive and effective means for the industrial hourly peak load forecasting.

  • PDF

An Equivalent Load Sharing by Wireless Parallel Operation Control in UPS

  • Byun, Young-Bok;Koo, Tae-Geun;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • Journal of KIEE
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2000
  • An equivalent load sharing control based on the frequency and voltage droop concept for parallel operation of two three-phase Uninterruptible Power Supply (UPS) systems with no control interconnection lines is presented in this paper. First of all, due to the use of active power and reactive power as control variables, the characteristics of output powers according to amplitude and phase differences between output voltages of two UPS systems are analyzed. Secondly, simulation results under different line impedance demonstrate the feasibility of the wireless parallel operation control. Finally, experiments are presented to verify the theoretical discussion with two three-phase 20kVA UPS systems employed TMS320C32, a kind of real time digital signal processor (DSP).

  • PDF

압전변압기의 특성분석 및 적응성 제어를 위한 안정화 설계

  • Yun, Seok-Taek;Mun, Hong-Ryeol;Won, Yeong-Jin;Lee, Jin-Ho;Kim, Jin-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.233-233
    • /
    • 2009
  • Piezoelectric Transformer (PT) was emerged in device and material industry. PT has some advantages such as low profile and mechanical energy transfer with little electromagnetic interface (EMI). But, It is known that the maximum PT efficiency can be obtained when it operates near the resonant frequency of the PT. Also PT's resonant frequency moves according to the load conditions Therefore, As the operating frequency moves further from the resonant frequency, the PT efficiency decreases dramatically due to the increase of the circulating current. This paper proposes analyzes modeling of PT convert and propose a guide-line to adaptive control

  • PDF

Impedance modulation of anthropomorphic robots with kinematic and force redundancies (여유자유도/여유구동 인체형 로봇의 임피던스 생성방식)

  • 이병주;김희국;이재훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1289-1292
    • /
    • 1997
  • Typical biomechanical system such as human body and mammals possess abundant muscles which are more than required for motion generation of such systems. We have shown that the excess number of muscles play important roles in spring-like impedance modulation. redundant kinematic structure, which is another feature of biomechanical systems, allows modulations of inertia and damping properties of such systems. In this work, we propose a frequency modulation algorithm which combines the spring-like impedance with inertia impedance. also, a load distribution method for frequency modulation is also introduced. The frequency modulation represents a simulataneous control of force and kinematic redundancies, which has not been addressed in the literature.

  • PDF

Control of Ultrasonic Motor Using Two-Phase High Frequency Inverter (2상 고주파 인버터에 의한 초음파 모터 제어)

  • Heo, J.Y.;Cho, G.B.;Baek, H.L.;Oh, K.G.;Jeung, H.S.;Yu, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.462-464
    • /
    • 1994
  • In this paper, noble electrical equivalent circuit ultrasonic motor is applied by model of parallel one from mechanical equation of piezoelectric device and characteristics estimation is done by equivalent converter. Uitrasonic motor is driven by oscillation circuit of two-phase high frequency inverter. Operating frequency of inverter is described by tracking control method of resonance frequency, according to change of load, temperature etc.

  • PDF

Battery Energy Storage System Based Controller for a Wind Turbine Driven Isolated Asynchronous Generator

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.81-90
    • /
    • 2008
  • This paper presents an investigation of a voltage and frequency controller for an isolated asynchronous generator (IAG) driven. by a wind turbine and supplying 3-phase 4-wire loads to the isolated areas where a grid is not accessible. The control strategy is based on the indirect current control of the VSC (voltage source converter) using the frequency PI controller. The proposed controller consists of three single-phase IGBT (Insulated Gate Bipolar Junction Transistor) based VSC, which are connected to each phase of the IAG through three single phase transformers and a battery at their DC link. The controller has the capability of controlling reactive and active powers to regulate the magnitude and frequency of the generated voltage, harmonic elimination, load balancing and neutral current compensation. The proposed isolated system is modeled and simulated in MATLAB using Simulink and PSB (Power System Block-set) toolboxes to verify the performance of the controller.