• 제목/요약/키워드: Load evaluation

검색결과 3,643건 처리시간 0.03초

교량 상시계측시스템을 이용한 실시간 안전성평가시스템 구축 방안 (A Safety Evaluation Strategy Employing Bridge Health Monitoring System by Traffic Loads)

  • 이우상;주봉철;박기태
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.481-484
    • /
    • 2008
  • The research was carried out to suggest the bridge health monitoring systems that have been composed damage detection algorithm and a system for evaluation load carrying capacity of bridge by traffic loads for the purpose of safety management of bridge structure in efficient and economic.

  • PDF

틸팅차량 주행에 따른 기존선 궤도의 주행안정성 평가 (Stability Evaluation of Track on Conventional Line According to Traveling Tilting Train)

  • 박용걸;엄기영;최정열;성덕룡
    • 한국철도학회논문집
    • /
    • 제10권6호
    • /
    • pp.701-708
    • /
    • 2007
  • 기존선 속도향상을 위해 개발된 틸팅열차는 기존열차에 비하여 승차감의 저하 없이 곡선부를 더욱 빠르게 주행할 수 있기 때문에 전체 운행시간을 단축시킬 수 있는 장점이 있다. 그러나 일반적으로 주행열차에 의해 궤도에 발생하는 힘은 주행속도의 함수로 표현되므로 주행속도가 증가하는 만큼 궤도가 부담해야할 힘의 크기도 증가하게 된다. 따라서 본 연구에서는 틸팅차량의 기존선 곡선부 주행 시 내 외측 레일의 탈선계수를 산정하여, 곡선반경 증속 여부, 선로개량 유 무에 따른 주행안정성을 평가하였으며, 기존에 운행중인 일반열차와 고속열차의 주행안정성을 비교, 분석하였다. 연구결과, 측정대상 구간에서 측정된 동적 윤중을 이용하여 산출한 동적 윤중 감소량은 차체진동을 고려한 차량 전복에 대한 동적윤중 감소한계치를 모두 만족하는 것으로 나타나 향후 틸팅차량 투입시 대상구간에서의 윤중 감소에 따른 열차탈선의 위험은 없을 것으로 판단된다.

LES 난류모델을 이용한 초음속 증기 충돌제트의 과도하중 특성에 대한 수치해석 연구 (Numerical Analysis on the Transient Load Characteristics of Supersonic Steam Impinging Jet using LES Turbulence Model)

  • 오세홍;최대경;박원만;김원태;장윤석;최청열
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.77-87
    • /
    • 2018
  • In the case of high-energy line breaks in nuclear power plants, supersonic steam jet is formed due to the rapid depressurization. The steam jet can cause impingement load on the adjacent structures, piping systems and components. In order to secure the design integrity of the nuclear power plant, it is necessary to evaluate the load characteristics of the steam jet generated by high-energy pipe rupture. In the design process of nuclear power plant, jet impingement load evaluation was usually performed based on ANSI/ANS 58.2. However, U.S. NRC recently pointed out that ANSI/ANS 58.2 oversimplifies the jet behavior and that some assumptions are non-conservative. In addition, it is recommended that dynamic analysis techniques should be applied to consider transient load characteristics. Therefore, it is necessary to establish an evaluation methodology that can analyze the dynamic load characteristics of steam jet ejected when high energy pipe breaks. This research group has developed and validated the CFD analysis methodology to evaluate the transient behavior of supersonic impinging jet in the previous study. In this study, numerical study on the transient load characteristics of supersonic steam jet impingement was carried out and amplitude and frequency analysis of transient jet load was performed.

수공구조물 설계 시스템의 위험도 평가와 불확실성 해석 (Risk Evaluation and Uncertainty Analysis in Hydraulic Design system)

  • 장석환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권4호
    • /
    • pp.194-200
    • /
    • 1998
  • Risk, probability of failure, which includes various uncertainties and influential factors of performance should be accounted for in engineering system. Recently, several different methods to analysis risk evaluation evolved and one of the practical method is FOSM (First Order Second Moment Method ). FOSM method is derived in terms of terms coefficient of variance to uncertainties which influence various factor. For risk evaluation and uncertainty analysis in hydraulic design system, load-capacity relationship is adopted in this paper. Sample catchment with design of sewer system is applied, which plots safety factor vs. risk. Risk evaluation and uncertainty analysis are very to important develop optimal design model in hydraulic system

  • PDF

원전 배관 손상압력 평가를 위한 파열시험 및 유한요소해석 (Burst Test and Finite Element Analysis for Failure Pressure Evaluation of Nuclear Power Plant Pipes)

  • 윤민수;김성환;김태순
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.144-149
    • /
    • 2015
  • This study aims to quantitatively evaluate failure pressure of wall-thinned elbow under combined load along with internal pressure, by conducting real-scale burst test and finite element analysis together. For quantitative evaluation, failure pressure data was extracted from the real-scale burst test first, and then finite element analysis was carried out to compare with the test result. For the test, the wall-thinning defect of the extrados or intrados inside the center of 90-degree elbow was considered and the loading modes to open or close the specimen maintaining a certain load or displacement were applied. Internal pressure was applied until failure occurred. As a result, when the bending load was applied under the load control condition, the intrados of the defect was more affected by failure pressure than the extrados, and the opening mode was more vulnerable to failure pressure than the closing mode. When the bending load was applied under the displacement control, it was hardly affected by failure pressure though it was slightly different from the defect position. The result of the finite element analysis showed a similar aspect with the test. Moreover, when major factors such as material properties and pipeline thickness were calibrated to accurate values, the analytical results was more similar to the test results.

역해석과 소형펀치 시험에 의한 발전설비 용접부의 소성유동특성 평가 (An Evaluation of Plastic Flow Characteristic for local structure of Weldment in Power Plant using SP test and Inverse FEA)

  • 백승세;권일현;김회현;이동환;양성모;유호선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.308-313
    • /
    • 2004
  • SP test has been confirmed the availability, however the application of SP test is hampered because the relation of stress-strain and load-displacement is not determined definitely. This study suggested an evaluation technique of plastic flow characteristic for X20CrMoV121 steel weldment through inverse analysis using SP test and finite element analysis(FEA). From the result, good agreement was found in load-displacement curves obtained from SP test and FEA. Also, The behavior of load-displacement curve from FEA show a rule that load is increase with increasing K(strength coefficient) and displacement is increase with increasing n(work hardening index). From the inverse analysis, true stress-strain curve could be obtained for each local structure of weldment. And the CGHAZ and WM, which showed lower load- displacement behavior, have smaller work hardening index, while FGHAZ have the largest index.

  • PDF

A framework for carrying out train safety evaluation and vibration analysis of a trussed-arch bridge subjected to vessel collision

  • Xia, Chaoyi;Zhang, Nan;Xia, He;Ma, Qin;Wu, Xuan
    • Structural Engineering and Mechanics
    • /
    • 제59권4호
    • /
    • pp.683-701
    • /
    • 2016
  • Safety is the prime concern for a high-speed railway bridge, especially when it is subjected to a collision. In this paper, an analysis framework for the dynamic responses of train-bridge systems under collision load is established. A multi-body dynamics model is employed to represent the moving vehicle, the modal decomposition method is adopted to describe the bridge structure, and the time history of a collision load is used as the external load on the train-bridge system. A (180+216+180) m continuous steel trussed-arch bridge is considered as an illustrative case study. With the vessel collision acting on the pier, the displacements and accelerations at the pier-top and the mid-span of the bridge are calculated when a CRH2 high-speed train running through the bridge, and the influence of bridge vibration on the running safety indices of the train, including derailment factors, offload factors and lateral wheel/rail forces, are analyzed. The results demonstrate that under the vessel collision load, the dynamic responses of the bridge are greatly enlarged, threatening the running safety of high-speed train on the bridge, which is affected by both the collision intensity and the train speed.

도로 하중조건을 고려한 상용차 판스프링의 피로강도 평가 II (Fatigue Strength Evaluation of LCV Leaf spring Considering Road Load Response II)

  • 손일선;배동호;정원석;정원욱;박순철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1127-1132
    • /
    • 2003
  • Suspension system of vehicle have enough endurance during its life time to protect passenger. Spring is one of major part of vehicle. Thus, a fatigue strength evaluation for leaf spring based on road load response was carried out. At first, strain of leaf spring is measured on the city condition and proving ground condition. And next, the damage analysis of road load response data was carried out. And fatigue test of leaf spring were also carried out. Based on -N life relation, fatigue life of leaf spring was evaluated at belgian mode, city mode and drawing test specification. After that, it is compared the design life of leaf spring and evaluated fatigue life by belgian mode, city mode and drawing test specification. From the above, the maximum load-fatigue life relation of leaf spring was defined by test. and new test target of belgian mode and city mode was proposed to accept design specification of leaf spring. It is expect that proposed test target can verify leaf spring fatigue endurance at specific road condition.

  • PDF

실내 부하조건에 따른 바닥공조 시스템의 에너지 성능 평가 (An Energy Performance Evaluation of UFAD System under the Various Conditions of Thermal Load)

  • 윤성훈;장향인;김경아;유기형;서승직
    • 설비공학논문집
    • /
    • 제25권1호
    • /
    • pp.14-19
    • /
    • 2013
  • The present study has been conducted for evaluating and comparing the performance of the underfloor air distribution system(UFAD) and the ceiling based air distribution system(CBAD) under cooling condition. Simulations and experiments were carried out for verifying the model by TRNSYS program about UFAD and CBAD. The results of simulation for various conditions of thermal load are summarized as followings. UFAD had an advantage for making thermal comfort because of lower temperature of the floor surface. Moreover, UFAD showed lower fan power about 30~50% than CBAD under the same conditions of thermal load. The energy saving rates of UFAD were increased to 17.7% in proportion to the thermal load on unoccupied zone(lighting). Ultimately, additional investigations should be done for analyzing optimized operating conditions of UFAD with considering the thermal performance of building envelop and the thermal load.

초기처짐을 갖는 좌굴방정식을 이용한 교량의 내하력 평가 (Evaluation of the Load Carrying Capacity of Existing Bridges Using Buckling Equation With Initial Deflection)

  • 기완서;양승현
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.2032-2037
    • /
    • 2009
  • 본 논문은 공용중인 교량구조물의 내하력 평가시 획일적이고 실제 거동특성을 적극적으로 활용하지 않아 발생할 수 있는 내하력 평가의 오류에 대하여 연구하였다. 내하력의 평가시 지점의 경계조건과 같은 현재의 거동특성을 반영하기 위하여 초기 결함을 갖는 부재에 대한 좌굴방정식에 처짐을 적용시켜 산정된 축방향력과 처짐에 의해 구해진 모멘트를 고려하여 교량의 내하력을 평가하였다. 기존의 내하력 평가시에 다소 획일적으로 적용되어지는 응력보정 계수를 좌굴방정식을 통하여 각 주형에 대하여 선 반영함으로서 내하력 평가의 오류를 다소 제거하고자 하였다.