• Title/Summary/Keyword: Load density

Search Result 1,071, Processing Time 0.034 seconds

An Efficient Data Centric Storage Scheme with Non-uniformed Density of Wireless Sensor Networks (센서의 불균일한 배포밀도를 고려한 효율적인 데이터 중심 저장기법)

  • Seong, dong-ook;Lee, seok-jae;Song, seok-il;Yoo, jae-soo
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2007.11a
    • /
    • pp.135-139
    • /
    • 2007
  • Recently Data Centric Storage (DCS) schemes are variously studied for several applications (e.g. natural environment investigation, military application systems and environmental changes monitoring). In DCS scheme, data is stored at nodes within the network by name. There are several drawbacks in the existing schemes. The first is the inefficiency of the range query processing on not considered the locality of store point. the second is the non-homogeneity of store load of each sensors in case of the sensor distribution density is non-uniformed. In this paper, we propose a novel data centric storage scheme with the sensor distribution density which satisfied with the locality of data store location. This scheme divides whole sensor network area using grid and distributes the density bit map witch consist of the sensor density information of each cell. sensors use the density bit map for storing and searching the data. We evaluate our scheme with existing schemes. As a result, we show improved load balancing and more efficient range query processing than existing schemes in environment which sensors are distributed non-uniform.

  • PDF

Influence of M.7 Apple Rootstock on Productivity and Fruit Quality of High Density 'Fuji', 'Hongro' and 'Sansa' Apple Trees (M.7 사과 대목이 고밀식 '후지' , '홍로' , '산사' 사과나무의 생산량 및 과실품질에 미치는 영향)

  • Young Soon Kwon;Jeong-Hee Kim;Dong-Hoon Sagong;Jong Taek Park
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.3
    • /
    • pp.239-252
    • /
    • 2023
  • Most apple trees in South Korea are grafted on M.9 and M.26 rootstocks; however, these rootstocks are susceptible to fire blight. Although M.7 rootstocks are moderately resistant to fire blight, they tend to exhibit excessive vigor, which is unsuitable for high-density planting, unless weak cultivars are used. This study investigated the vegetative growth, yield, and fruit quality of apple trees grafted onto M.7, M.9, or M.26 rootstocks to assess the feasibility of establishing high-density apple orchards domestically using the M.7 rootstock a period of seven years (1-7 years after planting). Rootstocks were tested using three cultivars with contrasting induced vigor and harvesting times: vigorous and late-maturing 'Fuji,' moderate vigor and middle-maturing 'Hongro,' and low vigor and early-maturing 'Sansa.' The planting density was maintained constant, with 190 trees per 10 a. Primary thinning (leaving only the king fruit on clusters) was performed, whereas secondary thinning (controlling crop load) was not. Vegetative growth, accumulated yield per 10 a, and yield efficiency varied depending on cultivars and rootstocks; however, the cultivars had a more notable effect on fruit quality than the rootstocks. Biennial bearing often occurred in the M.26 rootstock. 'Fuji'/M.7 was overly vigorous for high-density planting. The fruit quality and accumulated yield per 10 a of M.7 were similar to those of M.9 with the 'Hongro' and 'Sansa' cultivars. In particular, 'Hongro'/M.7 did not show tree vigor reduction due to heavy crop load, and the degree of biennial bearing in 'Sansa'/M.7 was not particularly high. These results indicated that high-density apple planting using the M.7 rootstock was achievable using the 'Hongro' and 'Sansa' cultivars.

Assessment of capacity curves for transmission line towers under wind loading

  • Banik, S.S.;Hong, H.P.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.1-20
    • /
    • 2010
  • The recommended factored design wind load effects for overhead lattice transmission line towers by codes and standards are evaluated based on the applicable wind load factor, gust response factor and design wind speed. The current factors and design wind speed were developed considering linear elastic responses and selected notional target safety levels. However, information on the nonlinear inelastic responses of such towers under extreme dynamic wind loading, and on the structural capacity curves of the towers in relation to the design capacities, is lacking. The knowledge and assessment of the capacity curve, and its relation to the design strength, is important to evaluate the integrity and reliability of these towers. Such an assessment was performed in the present study, using a nonlinear static pushover (NSP) analysis and incremental dynamic analysis (IDA), both of which are commonly used in earthquake engineering. For the IDA, temporal and spatially varying wind speeds are simulated based on power spectral density and coherence functions. Numerical results show that the structural capacity curves of the tower determined from the NSP analysis depend on the load pattern, and that the curves determined from the nonlinear static pushover analysis are similar to those obtained from IDA.

A Study on Combustion And Exhaust Emissions of Diesel Engine -For Gas Oil-Water Emulsified Fuel- (디젤 기관의 연소와 배출물에 관한 연구 -경유-물물의 유화연료 사용시-)

  • 조진호;김형섭;박정률
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.180-188
    • /
    • 1992
  • By means of the compatibility according to solving environmental pollution and energy problem due to the emissions of NOx and smoke from diesel engine this paper experimentally inspected the effect of using emulsified fuel, gas oil-water, for combustion characteristic, that is combustion pressure, pressure rise rate, heat generating rate, the period of ignition delay and specific fuel consumption, and CO, HC, NOx concentration and smoke density. When using emulsified fuel, as a water addition rate was increased, combustion pressure, pressure rise rate and heat generating rate was increased, the period of ignition delay was lengthening, the specific fuel consumption was some what increased in contrast to diesel fuel in low load, but deceased in high load region. And NOx concentration was decreased, CO concentration was increased in low load, but decreased in high load region, HC concentration was increased in contrast to diesel fuel in all region.

A study on the Maximum Power Point Tracking Control System of Wind Power Generation (풍력발전의 최대전력점 추종제어 방법에 관한 연구)

  • Ko, Seok-Cheol;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking (MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

A study on the Maximum Power Point Tracking Control System of Wind Power Generation (풍력발전의 최대전력점 추종제어 방법에 관한 연구)

  • Ko, Seok-Cheol;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) Is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking(MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

Bacterial load and drug resistance in sewage from industrially polluted regions of South Gujarat region

  • Aneree Desai;Srivathsa Nallanchakravarthula
    • Advances in environmental research
    • /
    • v.12 no.1
    • /
    • pp.1-15
    • /
    • 2023
  • Wastewater of anthropogenic origin is known to harbor various bacteria that are known to be of potential risk to human health and environment. It is of utmost importance to monitor such water sources. Coliforms present in the sewage water samples of municipal sewage treatment plants located at three different places in the South Gujarat region (Surat, Navsari and Vapi) of India were analyzed for their coliforms load as well as tested for their drug resistance. Using cultivation-based techniques microbial load and drug resistance (Amoxicillin, Tetracycline, Ciprofloxacin, Erythromycin, Trimethoprim and Sulphamethoxazole) were analyzed. Water treatment statistically significantly decreased the bacterial load in Vapi and Navsari samples. The optical density of with and without antibiotics of all the three locations was shown to increase significantly after 72 hours. Of all the isolates tested, except isolate 'VA5' (resisted up to 90 ㎍ of Ampicillin) all other isolates resisted 256 ㎍ concentration of antibiotics tested. This study indicates that the sewage water is being contaminated with drugs and/or antibiotics due to industrial and/or anthropogenic activities. Regular monitoring of the water quality is required followed by implementation of environmental laws for reducing the pollutants, that are of human health and environment concern.

Spatial and Temporal Variation Characteristics between Water Quality and Pollutant Loads of Yeong-il Bay (II) - Mutual Variation between Inflowing Pollutant Loads and Water Quality - (영일만 유입오염부하량과 수질의 시${\cdot}$공간적 변동특성(II) - 유입오염부하량과 수질의 상호거동 -)

  • YOON HAN-SAM;LEE IN-CHEOL;RYU CHEONG-RO
    • Journal of Ocean Engineering and Technology
    • /
    • v.17 no.5 s.54
    • /
    • pp.32-38
    • /
    • 2003
  • This study investigates the distribution characteristics and relationship of water quality, and analyzes the spatial and temporal variation and distribution of the pollutant loads at Yeong-il Bay. The results of these analysis, the concentrations of nutrient loads (T-N and T-P), both appeared to be at the maximum value in November, while most small values were taken in May for the T-N, and in August for the T-P. For COD, the maximum concentration was in August, which has much precipitation during the same season, T-N was at the mean, and T-P was at the minimum value. Using the cluster analysis to develop the division of the sea basin by the dendrogram, before and after construction of Pohang New-port, the variation characteristics of water quality of Yeong-il Bay were discussed. The in flowing pollutant loads were transported to the landward by the high-density salinity water volume of the bottom layer therefore, it formed nutrient trap or coastal trapping areas of the pollutant load. By this mechanism, it is clear that the water volume with high-density nutrient exists on both sides of the Pohang New-port. Thus, the sea basins increasing concentration of the pollutant load at Yeong-il Bay are most prevalent at Hyeong-san estuary, the Pohang Old, and New-port. To improve water quality of this sea basin, the reduction of these nutrients loads should be the highest priority.

The Weathering Index and Prediction of Uniaxial Compressive Strength for Chung-Ju Granite (충주 지역 화강암의 풍화지수 및 일축압축강도 추정에 관한 연구)

  • Eom, Tae-Uk;Kim, Hak-Mun;Kim, Chan-Kuk;Jang, Kyung-Jun;Pyo, Myung-Ryul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.863-874
    • /
    • 2008
  • We have to judge engineering properties of rock accurately in order to design and construct rock structure safely and economically. Among the rock tests, the test result of UCS(Uniaxial Compressive Strength) is very important factor used in the variety ways for designing and construction of underground structures, rock slope and foundation analysis. But the UCS test has some disadvantages of intact sample preparation such as because the shape of sample has to be regular cylindrical, cube or rectangular. In order to solve those problem, indirect tests are used such as point load test, schmidt hammer test, absorption test, dry density to predict UCS of rock. Those tests are easy to prepare sample and convenient to carry out the tests, so it is simple and costs less. Schmidt hammer test are frequently used in the construction site, because it is handy and easy to use, but there is concern of misuse without classifying the specification of each schmidt hammer. Thus, this study suggested presumptive numerical formula related on each specification of schmidt hammer test, point load test, absorption test and dry density also. We compared presumptive numerical formula and R-square through schmidt rebound assessment method already brought up. Also, through the test we offer the extent of weathering index according to the weathering grade.

  • PDF

Series Load Resonant High Frequency Inverter with ZCS-PDM Control Scheme for Induction-Heated Fusing Roller

  • Sugimura, Hisayuki;Kwen, Soon-Kurl;Koh, Kang-Hoon;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.415-420
    • /
    • 2005
  • This paper presents the two lossless auxiliary inductors-assisted voltage source type half bridge (single ended push pull: SEPP) series resonant high frequency inverter for induction heated king roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimental ones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proved from the practical point of view.

  • PDF