진상소전류시험용 Capacitor Load Bank 설계 (Design of Capacitor Load Bank for Capacitive Current Switching Tests)

  • 노창일;나대열;김선구;정흥수;김원만;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.106-108
    • /
    • 2002
  • Capacitive current switching test for circuit breaker and load breaker switch requires special attention because, after current interruption, the capacitive load contains an electrical charge and can cause dielectric restrike and re-ignition of the switching devices. therefore dielectric strength of capacitor load bank shall be able to withstand 4Vt (Vt : test voltage) and charging voltage discharged within 1 min. In this paper presents both characteristic of capacitive current switching tests and design of capacitor load bank.

  • PDF

와전류 동력계에서 계자전류를 이용한 부하토크의 측정에 관한 연구 (A Study on the Measurement of Load Torque by the Field Coil Current in an Eddy Current Dynamometer)

  • 문병수;이응석;이형석
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.84-92
    • /
    • 2001
  • Commercial eddy current dynamometers control the torque of rotating body, power supply machine, with the field coil current being operated as a braking force. In this paper, we studied the relation between field coil current and torque load of eddy current dynamometer. By the torque measuring analysis of eddy current dynamometer it is linear relation between the brake force measured from a torque meter which is installed at the case of dynamometer and the multiplied shaft rpm by the squares of field coil current (N$\times$I$^2$). To prove the relation, it was experimented and showed that the torque operated by the rotating body can be measured with the shaft rpm and the field coil current of the eddy current dynamometer. This result shows a possibility that eddy current dynamometer can measure the torque of rotating body without a torque measuring device. such as load cell.

  • PDF

Eddy current 동력계의 부하와 와전류의 직진성 관련 연구 (Linearity study for the field coil current and the load of eddy current dynamometer)

  • 문병수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 춘계학술대회논문집 - 한국공작기계학회
    • /
    • pp.66-72
    • /
    • 2000
  • Commercial eddy current dynamometers control the torque of ratating body (poer supply machine) with the field coil current being operated as a braking force. In this paper, we studied about the relation between the field coil current and the torque load of eddy current dynamometer. By the torque measuring analysis of eddy current dynamometer, it is linear relation between the brake force measured from the torque meter (e.g. load cell, strain gage or spring balance etc.) which is installed at the case of dynamometer and the multiply of shaft rpm by the square of field coil current (N$\times$Ia2). To prove the relation, it was experimented and showed that the torque operated by the rotating body can be measured with the shaft rpm and the field coil current of eddy current dynamometer. This result shows a possibility that eddy current dynamometer can measures the torque of rotating body without special torque measuring devices.

  • PDF

부하 불평형율에 대한 새로운 해석 (A New Analysis for Load Unbalance Factor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.67-72
    • /
    • 2006
  • Most of the load distributions in low voltage power feeder distribution systems are designed with approximately balanced and connected at the three phase four wire systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating load unbalance. Load unbalance factor is mainly affected by the impedance of load system. Unbalanced current will draw a highly unbalanced voltage. This paper presents a new calculation method for unbalance factor under the load variation at the three phase four wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared with the current unbalance factor. Two methods are indicated similar results.

Implementation of Zero-Ripple Line Current Induction Cooker using Class-D Current-Source Resonant Inverter with Parallel-Load Network Parameters under Large-Signal Excitation

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1251-1264
    • /
    • 2018
  • The systematic and effective design method of a Class-D current-source resonant inverter for use in an induction cooker with zero-ripple line current is presented. The design procedure is based on the principle of the Class-D current-source resonant inverter with a simplified load network model that is a parallel equivalent circuit. An induction load characterization is obtained from a large-signal excitation test-bench based on parallel load network, which is the key to an accurate design for the induction cooker system. Accordingly, the proposed scheme provides a systematic, precise, and feasible solution than the existing design method based on series-parallel load network under low-signal excitation. Moreover, a zero-ripple condition of utility-line input current is naturally preserved without any extra circuit or control. Meanwhile, a differential-mode input electromagnetic interference (EMI) filter can be eliminated, high power quality in utility-line can be obtained, and a standard-recovery diode of bridge-rectifier can be employed. The step-by-step design procedure explained with design example. The devices stress and power loss analysis of induction cooker with a parallel load network under large-signal excitation are described. A 2,500-W laboratory prototype was developed for $220-V_{rms}/50-Hz$ utility-line to verify the theoretical analysis. An efficiency of the prototype is 96% at full load.

펄스형 부하에서 ZVS Full-bridge PWM 컨버터의 효율 증대를 위한 제어 방법 (Efficient Control Method of ZVS Full-bridge PWM Converter with Pulse Load Current)

  • 김정원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.404-408
    • /
    • 2000
  • The novel control method of ZVS Full-bridge PWM converter with pulse load current is proposed. This new control method can reduce the switching loss of switches during no load condition. Moreover by using feed-forward load current information this method can obtain better transient dynamics compared to the system with only linear feedback control.

  • PDF

A Novel Claw Pole Eddy Current Load for Testing a DC Counter Rotating Motor Part I: Construction

  • Kanzi, Khalil;Dehafarin, Abolfazl;Roozbehani, Sam;Kanzi, Majid;Vasheghani, Qasem
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.321-329
    • /
    • 2012
  • Providing variable load for testing a motor in high speed conditions is usually a difficult task. The eddy current brake can be used in application of load testing of motors. This paper deals with construction of a novel claw pole eddy current brake which is employed as a load for a DC counter rotating motor (CRM). These kinds of motors have two inner and outer shafts that rotate in opposite directions simultaneously, which are particularly suitable for under water propulsion systems. The prototype 45KW eddy current brake consists of two parts. One of them is installed on the inner shaft of the 60KW DC CRM and the other one is installed on its outer shaft. The simulation and experimental results with prototype brakes are also analyzed by using MATLAB/Simulink and the operational characteristic of the brake is demonstrated as a function of the motor speed and current of the magnetic poles.

고속철도교량의 동적응답에 의한 충격계수 산정 (Impact Factor of High-Speed Railway Bridges from Dynamic Response under KTX Running)

  • 윤혜진;진원종;곽종원;황의승;김병석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1631-1635
    • /
    • 2011
  • To consider dynamic magnification effect at the static design stage, impact load factor is applied to design load. Current impact load factor adopted EUROCODE without verification while Japan suggested impact load factor including velocity of high-speed train throughout theoretical and experimental studies. On the purpose of evaluate current impact load factor, this study investigated the calculation of impact load factor from dynamic response of running train.

  • PDF

UPS inverter의 2차 데드비트 응답을 위한 반복부하예측기법 (Repetitive Load Prediction for Second Order Deadbeat Response Applied to UPS Inverter)

  • 최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.339-342
    • /
    • 2000
  • Repetitive Load Prediction is proposed for the UPS inverter application of the second order deadbeat controller which is robust against the calculation time delay and the parameter variation and which gets fast response against the load variation. The proposed technique predicts the load current ahead of two sampling time using that the load current is periodic. This is effective under nonlinear load condition. The proposed technique is derived theoretically and verified through simulation and experimental result.

  • PDF

주거용 건축물의 재실자밀도 기준 적정성 평가에 관한 연구 (A Study on the Adequacy Evaluation of Criteria of Occupant Load Factor in Residential Buildings)

  • 서동구;황은경
    • 한국주거학회논문집
    • /
    • 제27권6호
    • /
    • pp.145-153
    • /
    • 2016
  • The purpose of this study is to grasp the effectiveness of evacuation safety design by verifying the appropriateness of the standard of occupant load factor for residential buildings. To this end, the definition and current standard of occupant load factor for residential buildings were analyzed, and the problems of the current standard were clarified by interviewing professionals. In addition, changes in occupant load factor were examined by year based on statistical research, and evaluation on the current standard $18.6m^2/pers.$ was performed. As for evaluation methods, the need of redesigning of evacuation capacity was investigated by using evacuation simulation. As a result of the analysis, the most serious problem was clarification of the applicable standard for residential officetel, where the average occupant load factor was $26.1m^2/pers.$, which was not appropriate. However, as a result of evaluation on evacuation capacity, although there was no difference between statistical research results and the current standard in terms of evacuation capacity, when the standard for business facilities was applied to officetel, evacuation time doubled. Thus, this study suggests that when the current standard is applied to residential officetel, it is necessary to separate between residential use and business use.