• 제목/요약/키워드: Load compensator

검색결과 246건 처리시간 0.024초

Variable-Speed Prime Mover Driving Three-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation-Part H : Simulation and Experimental Results-

  • Ahmed, Tarek;Nagai, Schinichro;Soshin, Koji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.10-15
    • /
    • 2003
  • This paper presents the digital computer performance evaluations of the three-phase self-excited induction generator (SEIG) driven by the variable speed prime mover such as the wind turbine using the nodal admittance approach steady-state frequency domain analysis with the experimental results. The three-phase SEIG setup is implemented for small-scale rural renewable energy utilizations. The experimental performance results give a good agreement with those ones obtained from the digital computer simulation. Furthermore, a feedback closed-loop voltage regulation of the three-phase SEIG as a power conditioner which is driven by a variable speed prime mover employing the static VAR compensator (SVC) circuit composed of the thyristor phase controlled reactor (TCR) and the thyristor switched capacitor(TSC) is designed and considered herein for the wind-turbine driven the power conditioner. To validate the effectiveness of the SVC-based voltage regulator of the terminal voltage of the three-phase SEIG, an inductive load parameter disturbances in stand-alone are applied and characterized in this paper. In the stand-alone power utilization system, the terminal voltage response and thyristor triggering angle response of the TCR are plotted graphically. The simulation and the experimental results prove the effectiveness and validity of the proposed SVC which is controlled by the Pl controller in terms of fast response and high performances of the three-phase SEIG driven directly by the rural renewable energy utilization like a variable-speed prime mover.

퍼지 보상기를 사용한 리커런트 시간지연 신경망 제어기 설계 및 구현 (Design and Implementation of Recurrent Time Delayed Neural Network Controller Using Fuzzy Compensator)

  • 이상윤;신위재
    • 한국지능시스템학회논문지
    • /
    • 제13권3호
    • /
    • pp.334-341
    • /
    • 2003
  • 본 논문에서는 신경망제어기의 출력을 보상하는 퍼지보상기를 갖는 리커런트 시간 지연 신경망(RTDNN) 제어기를 제안하였다. 학습이 완료된 신경망제어기를 사용하더라도 예상치 못한 외란으로 인해 플랜트의 출력이 좋지 못한 경우가 있는데, 이것을 적절하게 조절해 주기 위해 퍼지보상기를 사용하여 원하는 결과를 얻을 수 있도록 하였다. 그리고 플랜트의 역모델 신경망을 학습시킨 결과를 이용하여 주 신경망의 가중치를 변경시킴으로서 원하는 플랜트의 동적 특성을 얻게 된다. 2차 플랜트를 통한 모의실험 결과가 시간 지연 신경망(TDNN)제어기보다 더 좋은 응답 특성을 가짐을 확인할 수 있다. 제안한 제어기의 성능을 확인하기 위해 유압 서보시스템을 대상으로 DSP 프로세서를 사용하여 구현한 후 실험결과를 통하여 제안된 방법의 유용성을 보였다.

Modeling and Analysis of the KEPCO UPFC System by EMTDC/PSCAD

  • Yoon, Jong-Su;Kim, Soo-Yeol;Chang, Byung-Hoon;Lim, Seong-Joo;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권3호
    • /
    • pp.148-154
    • /
    • 2003
  • This paper describes the development of KEPCO's 80MVA UPFC electromagnetic transient model and the analysis of its performance in the actual Korean power system. KEPCO's 80MVA UPFC is currently undergoing installation and will be ready for commercial operation from the year 2003. In order to apply a new FACTS device such as the UPFC to the actual power system, the utility needs, in advance, both load flow stability studies and transient studies. Therefore, KEPRI, the research institute of KEPCO, developed a detailed transient analysis model that is based on the actual UPFC S/W algorithm and H/W specifications. This simulation model is implemented by an EMTDC/PSCAD package. The results of the simulation show the effectiveness of UPFC operation in the KEPCO power system.

Optimal Particle Swarm Based Placement and Sizing of Static Synchronous Series Compensator to Maximize Social Welfare

  • Hajforoosh, Somayeh;Nabavi, Seyed M.H.;Masoum, Mohammad A.S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권4호
    • /
    • pp.501-512
    • /
    • 2012
  • Social welfare maximization in a double-sided auction market is performed by implementing an aggregation-based particle swarm optimization (CAPSO) algorithm for optimal placement and sizing of one Static Synchronous Series Compensator (SSSC) device. Dallied simulation results (without/with line flow constraints and without/with SSSC) are generated to demonstrate the impact of SSSC on the congestion levels of the modified IEEE 14-bus test system. The proposed CAPSO algorithm employs conventional quadratic smooth and augmented quadratic nonsmooth generator cost curves with sine components to improve the accurate of the model by incorporating the valve loading effects. CAPSO also employs quadratic smooth consumer benefit functions. The proposed approach relies on particle swarm optimization to capture the near-optimal GenCos and DisCos, as well as the location and rating of SSSC while the Newton based load flow solution minimizes the mismatch equations. Simulation results of the proposed CAPSO algorithm are compared to solutions obtained by sequential quadratic programming (SQP) and a recently implemented Fuzzy based genetic algorithm (Fuzzy-GA). The main contributions are inclusion of customer benefit in the congestion management objective function, consideration of nonsmooth generator characteristics and the utilization of a coordinated aggregation-based PSO for locating/sizing of SSSC.

새로운 벡터적 PLL를 이용한 대용량 무효전력 보상기(SVC)의 DSP 제어 (DSP BASED CONTROL OF HIGH POWER STATIC VAR COMPENSATOR USING NOVEL VECTOR PRODUCT PHASE LOCKED LOOP)

  • 정구호;조국춘;채균;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.262-264
    • /
    • 1996
  • This paper presents a new dual loop control using novel vector phase locked loop(VP-PLL) for a high power static var compensator(SVC) with three-level GTO voltage source inverter(VSI). Through circuit DQ-transformation, a simple dq-axis equivalent circuit is obtained. From this, DC analysis is carried out to obtain maximum controllable phase angle ${\alpha}_{max}$ per unit current between the three phase source and the switching function of inverter, and AC open-loop transfer function is given. Because ${\alpha}_{max}$ becomes small in high power SVC, this paper proposes VP-PLL for more accurate $\alpha$-control. As a result, the overall control loop has dual loop structure, which consists of inner VP-PLL for synchronizing the phase angle with source and outer Q-loop for compensating reactive power of load. Finally, the validity of the proposed control method is verified through the experimental results.

  • PDF

전기로 부하에서 SVC의 플리커 효과에 관한 연구 (A Study on the Fliker Effect of SVC in Electric Arc Furnace Loads)

  • 김경철;진성은;이일무
    • 조명전기설비학회논문지
    • /
    • 제20권8호
    • /
    • pp.48-53
    • /
    • 2006
  • 제철소에서 사용되고 있는 전기로는 전력계통에 전압 변동을 일으키며 시간에 따라 변하는 비선형 부하이다. 플리커는 전압 변동의 크기에 따라 램프의 방출 변화에 의한 인간의 지각 효과로 정의된다. 플리커 레벨은 전압 변동의 크기, 주파수 및 기간에 의해 결정된다. 본 논문에서는 전기로 부하로 인한 154[kV] 시스템에서의 전압 변동 문제를 측정하고, 플리커 저감을 위한 SVC 적용 결과를 분석하고, IEC 61000-3-7에 의하여 플리커를 평가하였다.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

전압손실 보상용 CO2 인버터 용접기 콘트롤라 개발 (Development of the CO2 Inverter Welding Controller for Compensation of Voltage Loss)

  • 배종일
    • 한국기계가공학회지
    • /
    • 제4권4호
    • /
    • pp.54-60
    • /
    • 2005
  • In a $CO_2$ inverter welding machine, stable arcs can be generated and a welding performance that is a goal of welding can be improved when stable electric power with a low voltage and a high current is supplied to a electrode that is the secondary part (output load terminal) and the base metal. For such a stable power supply, therefore, the AC arc welding machine, the thyristor welder, and the inverter welder have been developed in order according to development of the power electronics techniques. Up to now, the thyristor welding machine is still broadly used but the application volume is gradually reduced by development of the inverter welder. Because the welding performance of the inverter welder is very good and the weight and size of the welder is remarkably light and small. The final goal of this research is to develop the voltage loss compensator that is a drawback of the inverter welder and improve the welding performance using the developed compensator.

  • PDF

Cascaded Integrator-Comb 필터를 위한 근사 선형 위상 보상기 (Almost linear-phase compensator for Cascaded Integrator-Comb filter)

  • 이규하;이충용
    • 대한전자공학회논문지SP
    • /
    • 제42권4호
    • /
    • pp.153-158
    • /
    • 2005
  • 본 논문에서는 software defined radio(SDR) 등의 디지털 RF/IF(Intermediate Frequency)에 사용되는 CIC 필터의 처짐 현상을 위한 보상 필터를 제안한다. 제안된 보상 필터는 근사적 선형 위상 특성을 가지며, interpolator/decimator의 기저 대역에서 가장 낮은 레이트로 동작하는 2차의 필터이므로 저연산량을 요구하므로 비용 효율적이다. 또한 처짐 현상을 보상하면서도 저지대역에서는 성능 열화가 거의 발생하지 않는다 예제를 통한 설계 및 성능 분석 결과, 제안된 보상 방법을 적용한 통신 시스템에 있어서 성능 향상을 보였고, 기존의 보상 방법과 비교하여 성능 및 메모리 사용량, 연산량에서 우수함을 보였다.

동적전압보상기의 전압제어를 위한 PLL 방식의 개선 (Improvement of PLL Method for Voltage Control of Dynamic Voltage Restorer)

  • 김병섭;최종우
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.936-943
    • /
    • 2009
  • Dynamic voltage restorer(DVR) is now more preferable enhancement than other power quality enhancement in industry to reduce the impact of voltage faults, especially voltage sags to sensitive loads. The main controllers for DVR consists of PLL(phase locked loop), compensation voltage calculator and voltage compensator. PLL detects the voltage faults and phase. Compensation voltage calculator calculates the reference voltage from the source voltage and phase. With calculated compensation voltage from PLL, voltage compensator restores the source voltage. If PLL detect ideal phase, compensation voltage calculator calculates ideal compensation voltage. Therefore, PLL for DVR is very important. This paper proposes the new method of PLL in DVR. First, the power circuit of DVR system is analyzed in order to compensate the voltage sags. Based on the analysis, new PLL for improving transient response of DVR is proposed. The proposed method uses band rejection filter(BRF) at q-axis in synchronous flame. In order to calculate compensation voltage in commercial instruments, the PQR theory is used. Proposed PLL method is demonstrated through simulation using Matlab-Simulink and experiment, and by checking load voltage, confirms operation of the DVR