• Title/Summary/Keyword: Load cell

Search Result 1,181, Processing Time 0.036 seconds

Development of Load Cell Using Fiber Brags Grating Sensors and Differential Method for Structural Health Monitoring (구조 건전성 모니터링을 위한 광섬유 브래그 격자 센서와 차동법을 적용한 로드셀 개발)

  • Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.299-307
    • /
    • 2009
  • Emerging fiber optic sensor technologies have shown great potential to overcome the difficulties associated with conventional sensors. Fiber optic sensors are immune to EM noise and electric shock and thus can be used in explosion-prone areas. Several kinds of fiber optic sensors have been developed over the last two decades to take advantage of these merits. There have also been many field applications of fiber optic sensors for structural health monitoring as NDT/HDE. However, very few sensors, particularly a load cell have been successfully commercialized. This Paper Presents a load cell using fiber Bra99 gra1ing (FBG) sensors. The shape of the load cell is a link type, and three FBG sensors are used for measuring strains at three different points. Especially, these strains are processed with a differential method in order to exclude common mode noise such as temperature. Moreover, the sensitivity, the linearity and the resolution of the load cell were successfully verified from the experiment of tension test.

An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System (가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Woon-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.

Intelligent Diagnosis System for an Electronic Weighting Machine (전자 저울을 위한 지능형 고장 진단 시스템)

  • 김종원;김영구;조현찬;서화일;김두용;이병수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2001.12a
    • /
    • pp.78-82
    • /
    • 2001
  • Electronic Weighting Machine is used an electronic scale which has many trouble because of broken load cells. In this paper, we propose an intelligent Diagnosis System will for an electronic weighting machine using fuzzy logic. It's purpose be detect of the load cell's trouble. The electronic circuit of system, which call 'junction box', will be connected resistances in a series at circuit of Wheatstone Bridge for monitoring the condition of load cells.

  • PDF

Non-contact Stress Measurement in Steel Member of PSC Box Bridge Using Raman Spectroscopy (라만 형광 분광법을 이용한 PSC 박스교 인장케이블 응력측정방법 연구)

  • Kim, Jongwoo;Kim, Namgyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.2
    • /
    • pp.130-134
    • /
    • 2019
  • In this paper, a laser-based non-contact load cell is newly developed for measuring forces in prestressed concrete tendons. First, alumina particles have been sprayed onto an empty load cell which has no strain gauges on it, and the layer has been used as a passive stress sensor. Then, the spectral shifts in fluorescence spectroscopy have been measured using a laser-based spectroscopic system under various force levels, and it has been found that the relation of applied force and spectral shift is linear in a lab-scale test. To validate the field applicability of the customized load cell, a full-scale prestressed concrete specimen has been constructed in a yard. During the field test, it was, however, found that the coating surface has irregular stress distribution. Therefore, the location of a probe has to be fixed onto the customized load cell for using the coating layer as a passive stress sensor. So, a prototype customized load cell has been manufactured, which consists of a probe mount on its casing. Then, by performing lab-scale uniaxial compression tests with the prototype load cell, a linear relation between compression stress and spectrum shift at a specific point where laser light had been illuminated has been detected. Thus, it has a high possibility to use the prototype load cell as a force sensor of prestressed concrete tendons.

A Minimum Data-Rate Guaranteed Resource Allocation With Low Signaling Overhead in Multi-Cell OFDMA Systems

  • Kwon, Ho-Joong;Lee, Won-Ick;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.26-35
    • /
    • 2009
  • In this paper, we investigate how to do resource allocation to guarantee a minimum user data rate at low signaling overhead in multi-cell orthogonal frequency division multiple access (OFDMA) wireless systems. We devise dynamic resource allocation (DRA) algorithms that can minimize the QoS violation ratio (i.e., the ratio of the number of users who fail to get the requested data rate to the total number of users in the overall network). We assume an OFDMA system that allows dynamic control of frequency reuse factor (FRF) of each sub-carrier. The proposed DRA algorithms determine the FRFs of the sub-carriers and allocate them to the users adaptively based on inter-cell interference and load distribution. In order to reduce the signaling overhead, we adopt a hierarchical resource allocation architecture which divides the resource allocation decision into the inter-cell coordinator (ICC) and the base station (BS) levels. We limit the information available at the ICC only to the load of each cell, that is, the total number of sub-carriers required for supporting the data rate requirement of all the users. We then present the DRA with limited coordination (DRA-LC) algorithm where the ICC performs load-adaptive inter-cell resource allocation with the limited information while the BS performs intra-cell resource allocation with full information about its own cell. For performance comparison, we design a centralized algorithm called DRA with full coordination (DRA-FC). Simulation results reveal that the DRA-LC algorithm can perform close to the DRA-FC algorithm at very low signaling overhead. In addition, it turns out to improve the QoS performance of the cell-boundary users, and achieve a better fairness among neighboring cells under non-uniform load distribution.

Evaluation of the q-w Curve on Rock-Socketed Drilled Shafts by Triaxial Compression Tests (삼축압축시험을 통한 암반에 근입된 현장타설말뚝의 선단 하중전이곡선 산정)

  • Kim, Tae-Hyung;Kim, Yong-Min;Jeong, Sang-Seom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.455-465
    • /
    • 2008
  • In this study, the load distribution and deformation of rock-socketed drilled shafts subjected to axial load are investigated based on small scale model tests. In order to analyze the effects of major influencing factors of end bearing capacity, Hoek-cell triaxial tests were performed. From the test results, it was found that the initial slope of end bearing load transfer (q-w) curve was highly dependent on rock mass modulus and pile diameter, while the ultimate unit toe resistance ($q_{max}$) was influenced by rock mass modulus and the spacing of discontinuities. End bearing load transfer function of drilled shafts socketed in rock was proposed based on the Hoek-cell triaxial test results and the field loading tests which were performed on granite and gneiss in South Korea. Through the comparison with pile load tests, it is found that the load-transfer curve by the present study is in good agreement with the general trend observed by field loading tests, and thus represents a significant improvement in the prediction of load transfer of drilled shaft.

  • PDF

Prognostic Value of HPV18 DNA Viral Load in Patients with Early-Stage Neuroendocrine Carcinoma of the Uterine Cervix

  • Siriaunkgul, Sumalee;Utaipat, Utaiwan;Suwiwat, Supaporn;Settakorn, Jongkolnee;Sukpan, Kornkanok;Srisomboon, Jatupol;Khunamornpong, Surapan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3281-3285
    • /
    • 2012
  • Objectives: To evaluate the clinicopathologic correlation and prognostic value of HPV18 DNA viral load in patients with early-stage cervical neuroendocrine carcinoma (NECA). Methods: Formalin-fixed, paraffin-embedded tissue of cervical NECA patients with known HPV18 infection and clinicopathologic data including follow-up results were collected. The HPV18 DNA load was assessed with quantitative PCR targeting the HPV18 E6E7 region. Results: Twenty-one patients with early-stage (IB-IIA) cervical NECA were identified. HPV18 DNA viral load ranged from 0.83 to 55,174 copies/cell (median 5.90). Disease progression, observed in 10 cases (48%), was not significantly associated with any clinicopathologic variables. However, the group of patients with progressive disease tended to have a higher rate of pelvic lymph node metastasis (50% versus 9%, p=0.063) and a lower median value of HPV18 DNA viral load (4.37 versus 8.17 copies/cell, p=0.198) compared to the non-recurrent group. When stratified by a cut-off viral load value of 5.00 copies/cell, the group of patients with viral load ${\leq}5.00$ copies/cell had a significantly shorter disease-free survival than the group with viral load >5.00 copies/cell (p=0.028). The group with a lower viral load also tended to have a higher rate of disease progression (75% versus 31%, p=0.080). No significant difference in the other clinicopathologic variables between the lower and higher viral load groups was identified. Conclusion: HPV18 DNA viral load may have a prognostic value in patients with early-stage NECA of the cervix. A low viral load may be predictive of shortened disease-free survival in these patients.

Minimization of Cell-based Handoff Delays to Balance the Load in Fiber Optic Micro-cellular Systems (광마이크로셀 이동통신 시스템의 균등부하를 위한 셀단위 핸드오프 순서결정)

  • 이채영;장세헌
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.2
    • /
    • pp.1-11
    • /
    • 2001
  • This paper considers the scheduling of cell-based handoffs to balance the traffic in a fiber-optic microcelluar system. In the system depending on the order of cell based handoff, periodical balancing of the traffic among microcells can be achieved. The cell based handoff problem is formulated as a dynamic programming and the computational complexity is analyzed. Since the scheduling problem requires real time solution, heuristic algorithms are proposed and the computational results are discussed.

  • PDF

Transmission Scheduling Algorithm with Cell Loading Control in a DS/CDMA Cellular System

  • Yu, Zhi-cheng
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.85-88
    • /
    • 2002
  • Maintaining a proper level of cell lead, system throughput can be maximized by a transmission rate control over the uplink in DS/CDMA cellular system to support integrated services of real-time and delay-tolerant traffic. We find that the cell load-based rate control scheme can be further enhanced by taking the varying channel condition into account In conjunction with some fair scheduling algorithm. Our simulation results show that the proposed scheme outperforms the original cell load-based rate control with the round-robin sharing scheduling scheme.

  • PDF