• Title/Summary/Keyword: Load cell

Search Result 1,181, Processing Time 0.04 seconds

The Intelligent Monitoring System for a heavy weight scale (고 중량 측정 장치를 위한 지능형 모니터링 시스템)

  • 김영구;조현찬;정병우;김두용
    • Proceedings of the IEEK Conference
    • /
    • 2000.11c
    • /
    • pp.41-44
    • /
    • 2000
  • In this paper, we propose an Intelligent Monitoring Network System(IMNS) for The truck scale balance system. Truck scale balance system consis of three parts; Load cell part, Indicator part, and Junction box part. IMNS is attached to Junction box in truck scale balance system. Even if Load cell have been some problems, a truck scale balance system still has been run to determine, the values involved error. therefore prosed system is has concentrated on Load cell part. Other Parts have been changed a portion of circuit for monitoring system.

  • PDF

Development of Load-Cell-Based Anemovane (로드셀형 풍향풍속계 개발)

  • Jeon, Byeong Ha;Han, Dong Seop;Lee, Kwon-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.685-691
    • /
    • 2013
  • A load-cell-type anemovane operates based on wind vector properties. The developed load-cell-type anemovane is of a fixed type in which the wing does not rotate, unlike in the case of existing anemovanes. The load-cell-type anemovane is required to accurately derive the correlation between the load ratio and the wind direction in order to develop a qualified product. This is because the load ratio repeats every $90^{\circ}$ owing to the use of four load cells, and its value varies nonlinearly according to the wind direction. In this study, we compared analytical results with experimental results. Fluid analysis was carried out using ANSYS CFX. Furthermore, the prototype was tested using a self-manufactured wind tunnel. The wind direction was selected as the design variable. 13 selected wind direction conditions ranging from $0^{\circ}$ to $90^{\circ}$ with an interval of $7.5^{\circ}$ for analysis were defined. Furthermore, 10 wind direction conditions with an interval of $10^{\circ}$ for the experiment were defined. We derived the relations between the pressure ratio and the wind direction through the experiment and fluid analysis.

Load Sharing in Hierarchical Cell Structure for High Speed Downlink Packet Transmission (하향링크 고속 패킷 전송을 위한 계층적 셀 구조에서의 기지국간 부하 분배)

  • Jeong, Dong-Geun;Jeon, Wha-Sook
    • Journal of KIISE:Information Networking
    • /
    • v.29 no.5
    • /
    • pp.466-472
    • /
    • 2002
  • We investigate the load sharing problem between the umbrella cell and the overlaid tells in hierarchical cell structure. A load sharing strategy is proposed and its performance is evaluated by simulation when it is used for transmission of the mobile Internet traffic using the High Speed Downlink Packet Access scheme. The results show that, with the proposed strategy, the microcell backs well the overlaid picocells up, especially when a specific picocell cluster suffers unusual heavy load condition. By using the strategy, we can reduce the installation cost, otherwise needed for increasing the system capacity of every picocell cluster to cope with the unusual heavy load.

Design and Strain Analysis of Precision 3-component Load Cell

  • Kim, Gab-Soon;Rhee, Se-Hun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.22-32
    • /
    • 2000
  • This paper describes the development of a precision 3-component load cell with plate beams which may be used for measuring forces Fx, Fy and moment Mz simultaneously in industry. The equations to predict the bending strains on the surface of the beams under forces or moment are derived, the attachment location of strain gages of each sensor is determined, and 3-component load cell is carried out. It reveals that the rated strain calculated from the derived equations are good agreement with the results from Finite Element Method analysis.

  • PDF

Development of Real-time Checking System on Ringer's Solution Using Load Cell

  • Ha, Kwan-Yong;Nam, Chul;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1409-1412
    • /
    • 2005
  • Therefore this study focused on developing real-time system, which makes it possible for nurses to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution. This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by A/D converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

A Study on Real Time Measurement of Frictional Coefficients by using Multi-components Load Cell (다축 힘센서를 이용한 마찰계수 실시간 측정방법 연구)

  • 권현준;권영하;박경희;오택열;백영남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.481-485
    • /
    • 2003
  • This study describes the real-time measurement system which consist of multi-components load cell and linear motor. Operationg and data acquisition is controlled by PC. Multi-components load cell measures simultaneously the vertical force Fz and frictional force Fx when contactors move on sample surface. Linear motor is used to translate with constant speed without vibration. The frictional coefficient is calculated by Matlab$^{TM}$. The frictional coefficients between Al. plates. and fingertip and fabrics are measured.d.

  • PDF

Development of Load Cell to Measure Contact Force of Pantograph (판토그라프 접촉력 측정을 위한 스트레인 게이지 내장형 센서 개발)

  • Park, Chan-Kyoung;Paik, Jin-Sung;Kim, Young-Guk;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.947-953
    • /
    • 2010
  • The KTX-Sancheon has been commercially operating on the high-speed line since March. 2. In order to verify the performance of high-speed train and core equipments such as current collection system, sophisticated tests and evaluating procedures should have been considering. In this paper, the load cell with a built-in strain-gauge which developed to improve measuring method of contact force between the pantograph and catenary system is introduced. The static test results of the load cell shows that its design is very suitable and applicable for the dynamic test and on-line test. After the test and evaluation of load cell's dynamic calibration with pantograph, we will be applied to test interaction characteristics between the pantograph and catenary system on the high-speed line.

  • PDF

Fundamental Study on System Design as Load Character of the capacity Small Fuel Cell Vehicle (소형연료전지 자동차의 부하특성에 따른 시스템 설계에 관한 기초연구)

  • Kim H. G.;Kang Y W.;Kim Y. S.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.5
    • /
    • pp.75-80
    • /
    • 2004
  • Feasibility of the small capacity fuel cell powered vehicle is carried out for system design with loading characteristics. The major design concepts which include battery, driving motor, and fuel cell module are analyzed and discussed for the future development. A load characteristics program is developed in order to calculate the traction power of fuel cell vehicle according to the driving courses specified. Further, the small capacity fuel cell vehicle is analyzed to determine the capacity of stack as a function of the velocity for an appropriate power required.

Fuel Cell Stack Dynamics Modeling Considering Load Variation (부하의 변화를 고려한 연료전지 스택 동특성 모델링)

  • Ko, Jeong-Min;Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.93-99
    • /
    • 2009
  • In this paper, transient voltage response of Polmer Electrolyte Membrane Fuel Cell (PEMFC) stack is analyzed and voltage dynamic characteristic is modeled for optimal design of power conditioning system (PCS). According that the load is changed, the corresponding operating voltage of fuel cell stack is also varied with a certain deep and rising time due to the chemical and mechanical responses. This transient behavior can affect on the operation with respect of PI gain in controller, duty ratio, capacitor of capacitor and so on. So in this paper the detailed theoretical analysis of transient voltage dynamics is explained and the methodology of dynamic modeling is introduced. In addition, the validity and feasibility of the proposed dynamic model is verified by experimental results under various load conditions.

Characteristics of a Double-Tube Structure for the Hydraulic WIM Sensor

  • Moon, Young-Soon;Son, Won-Ho;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.19-23
    • /
    • 2014
  • A new hydraulic tube structure for WIM sensor of a new generation is presented in this paper. The double-tube structure has been developed in order to improve the performance of the hydraulic load cell. The double-tube structure hydraulic element could be reduced by 46% in pressure changes according to temperature compared to a single-tube structure. In addition to the nonlinearity can be reduced by 67.19% at the same load condition. The hydraulic load cell shows an excellent linearity and measurement accuracy as the result of the static load test.