• 제목/요약/키워드: Load cell

검색결과 1,183건 처리시간 0.026초

Characteristics of a Double-Tube Structure for the Hydraulic WIM Sensor

  • Moon, Young-Soon;Son, Won-Ho;Choi, Sie-Young
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.19-23
    • /
    • 2014
  • A new hydraulic tube structure for WIM sensor of a new generation is presented in this paper. The double-tube structure has been developed in order to improve the performance of the hydraulic load cell. The double-tube structure hydraulic element could be reduced by 46% in pressure changes according to temperature compared to a single-tube structure. In addition to the nonlinearity can be reduced by 67.19% at the same load condition. The hydraulic load cell shows an excellent linearity and measurement accuracy as the result of the static load test.

구조 건전성 모니터링을 위한 광섬유 브래그 격자 센서와 차동법을 적용한 로드셀 개발 (Development of Load Cell Using Fiber Brags Grating Sensors and Differential Method for Structural Health Monitoring)

  • 김대현
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.299-307
    • /
    • 2009
  • 광섬유 센서 기술은 기존의 상용 센서의 어려움을 극복할 수 있어 전자기학 잡음과 전기 쇼크의 영향이 강한 폭발환경에서도 충분히 사용이 가능하다. 최근 이러한 장점들로 인해 여러 종류의 광섬유 센서들이 활발히 연구 개발되고 있다. 또한 비파괴검사/평가 분야로써 구조 건전성 감시를 위한 광섬유 센서의 다양한 적용 연구 분야가 존재한다. 그러나 로드셀과 같은 종류의 센서들은 상대적으로 상용화가 미흡한 실정이다. 본 논문에서는 광섬유 브래그 격자 센서를 사용한 광섬유 로드셀을 보여준다. 본 로드셀의 형상은 링크타입이고, 세 개의 광섬유 브래그 격자 센서를 사용하여 세 지점의 변형률을 각기 측정한다 특히 이들 변형률은 온도와 같은 동상 잡음을 제거하기 위해 차동법을 사용하여 신호처리 된다. 더 나아가 본 로드셀의 감도, 선형성 그리고 해상도를 인장실험을 통해 성공적으로 검증하였다.

가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가 (An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System)

  • 박찬엄;정진수;한운기
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.

전자 저울을 위한 지능형 고장 진단 시스템 (Intelligent Diagnosis System for an Electronic Weighting Machine)

  • 김종원;김영구;조현찬;서화일;김두용;이병수
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2001년도 추계학술대회 학술발표 논문집
    • /
    • pp.78-82
    • /
    • 2001
  • Electronic Weighting Machine is used an electronic scale which has many trouble because of broken load cells. In this paper, we propose an intelligent Diagnosis System will for an electronic weighting machine using fuzzy logic. It's purpose be detect of the load cell's trouble. The electronic circuit of system, which call 'junction box', will be connected resistances in a series at circuit of Wheatstone Bridge for monitoring the condition of load cells.

  • PDF

불루투스 디지털 로드 셀을 이용한 크레인 하중검출 방법 (Crane Load Detection Method Using Bluetooth Digital Load Cell)

  • 유치국;황용연;배종일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.107-109
    • /
    • 2007
  • From composition transmitter is detached in indicator to individual load direction of 2 channels and adding up display by digital load cell indicator indication method of Bluetooth method is identifying marks.

  • PDF

라만 형광 분광법을 이용한 PSC 박스교 인장케이블 응력측정방법 연구 (Non-contact Stress Measurement in Steel Member of PSC Box Bridge Using Raman Spectroscopy)

  • 김종우;김남규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.130-134
    • /
    • 2019
  • 본 논문에서는 레이저기반 응력측정을 위한 비접촉식 로드셀을 개발을 위하여, 실내실험을 통하여 기술을 검증하고, 실규모 실험을 통하여 문제점을 파악하였으며, 최종적으로 현장적용에 적합한 응력측정용 비접촉식 로드셀 프로토타입을 개발하였다. 이를 위하여, 중심공 압축타입의 로드셀 제작에 사용되는 로드셀 몸체 표면에 용사코팅기술을 이용하여 알루미나를 도포하고, 레이저를 기반으로한 압분광법을 이용하여, 비접촉식으로 응력을 계측하였다. 이때, 인가되는 응력과 스펙트럼 이동간의 관계가 선형임을 확인하였다. 해당 기술의 현장 적용성 확인을 위하여, 실규모 프리스트레스 콘크리트 시편을 제작하고, 레이저를 조사하여 인가된 응력을 확인하는 과정에서, 반복적인 상황 하에서 레이저 조사 위치가 동일해야 함을 확인하였다. 이를 보완하기 위하여 프로브를 고정할 수 있는 케이싱이 포함된 로드셀 프로토타입을 제작하였고, 실내일축압축시험을 통하여 압축력과 스펙트럼 이동간의 선형성을 확인하였다. 따라서, 본 연구를 통하여 개발된 비접촉식 로드셀을 이용하여, 압축력을 효과적으로 측정할 수 있을 것으로 기대된다.

A Minimum Data-Rate Guaranteed Resource Allocation With Low Signaling Overhead in Multi-Cell OFDMA Systems

  • Kwon, Ho-Joong;Lee, Won-Ick;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • 제11권1호
    • /
    • pp.26-35
    • /
    • 2009
  • In this paper, we investigate how to do resource allocation to guarantee a minimum user data rate at low signaling overhead in multi-cell orthogonal frequency division multiple access (OFDMA) wireless systems. We devise dynamic resource allocation (DRA) algorithms that can minimize the QoS violation ratio (i.e., the ratio of the number of users who fail to get the requested data rate to the total number of users in the overall network). We assume an OFDMA system that allows dynamic control of frequency reuse factor (FRF) of each sub-carrier. The proposed DRA algorithms determine the FRFs of the sub-carriers and allocate them to the users adaptively based on inter-cell interference and load distribution. In order to reduce the signaling overhead, we adopt a hierarchical resource allocation architecture which divides the resource allocation decision into the inter-cell coordinator (ICC) and the base station (BS) levels. We limit the information available at the ICC only to the load of each cell, that is, the total number of sub-carriers required for supporting the data rate requirement of all the users. We then present the DRA with limited coordination (DRA-LC) algorithm where the ICC performs load-adaptive inter-cell resource allocation with the limited information while the BS performs intra-cell resource allocation with full information about its own cell. For performance comparison, we design a centralized algorithm called DRA with full coordination (DRA-FC). Simulation results reveal that the DRA-LC algorithm can perform close to the DRA-FC algorithm at very low signaling overhead. In addition, it turns out to improve the QoS performance of the cell-boundary users, and achieve a better fairness among neighboring cells under non-uniform load distribution.

삼축압축시험을 통한 암반에 근입된 현장타설말뚝의 선단 하중전이곡선 산정 (Evaluation of the q-w Curve on Rock-Socketed Drilled Shafts by Triaxial Compression Tests)

  • 김태형;김용민;정상섬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.455-465
    • /
    • 2008
  • In this study, the load distribution and deformation of rock-socketed drilled shafts subjected to axial load are investigated based on small scale model tests. In order to analyze the effects of major influencing factors of end bearing capacity, Hoek-cell triaxial tests were performed. From the test results, it was found that the initial slope of end bearing load transfer (q-w) curve was highly dependent on rock mass modulus and pile diameter, while the ultimate unit toe resistance ($q_{max}$) was influenced by rock mass modulus and the spacing of discontinuities. End bearing load transfer function of drilled shafts socketed in rock was proposed based on the Hoek-cell triaxial test results and the field loading tests which were performed on granite and gneiss in South Korea. Through the comparison with pile load tests, it is found that the load-transfer curve by the present study is in good agreement with the general trend observed by field loading tests, and thus represents a significant improvement in the prediction of load transfer of drilled shaft.

  • PDF

Prognostic Value of HPV18 DNA Viral Load in Patients with Early-Stage Neuroendocrine Carcinoma of the Uterine Cervix

  • Siriaunkgul, Sumalee;Utaipat, Utaiwan;Suwiwat, Supaporn;Settakorn, Jongkolnee;Sukpan, Kornkanok;Srisomboon, Jatupol;Khunamornpong, Surapan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권7호
    • /
    • pp.3281-3285
    • /
    • 2012
  • Objectives: To evaluate the clinicopathologic correlation and prognostic value of HPV18 DNA viral load in patients with early-stage cervical neuroendocrine carcinoma (NECA). Methods: Formalin-fixed, paraffin-embedded tissue of cervical NECA patients with known HPV18 infection and clinicopathologic data including follow-up results were collected. The HPV18 DNA load was assessed with quantitative PCR targeting the HPV18 E6E7 region. Results: Twenty-one patients with early-stage (IB-IIA) cervical NECA were identified. HPV18 DNA viral load ranged from 0.83 to 55,174 copies/cell (median 5.90). Disease progression, observed in 10 cases (48%), was not significantly associated with any clinicopathologic variables. However, the group of patients with progressive disease tended to have a higher rate of pelvic lymph node metastasis (50% versus 9%, p=0.063) and a lower median value of HPV18 DNA viral load (4.37 versus 8.17 copies/cell, p=0.198) compared to the non-recurrent group. When stratified by a cut-off viral load value of 5.00 copies/cell, the group of patients with viral load ${\leq}5.00$ copies/cell had a significantly shorter disease-free survival than the group with viral load >5.00 copies/cell (p=0.028). The group with a lower viral load also tended to have a higher rate of disease progression (75% versus 31%, p=0.080). No significant difference in the other clinicopathologic variables between the lower and higher viral load groups was identified. Conclusion: HPV18 DNA viral load may have a prognostic value in patients with early-stage NECA of the cervix. A low viral load may be predictive of shortened disease-free survival in these patients.

광마이크로셀 이동통신 시스템의 균등부하를 위한 셀단위 핸드오프 순서결정 (Minimization of Cell-based Handoff Delays to Balance the Load in Fiber Optic Micro-cellular Systems)

  • 이채영;장세헌
    • 한국경영과학회지
    • /
    • 제26권2호
    • /
    • pp.1-11
    • /
    • 2001
  • This paper considers the scheduling of cell-based handoffs to balance the traffic in a fiber-optic microcelluar system. In the system depending on the order of cell based handoff, periodical balancing of the traffic among microcells can be achieved. The cell based handoff problem is formulated as a dynamic programming and the computational complexity is analyzed. Since the scheduling problem requires real time solution, heuristic algorithms are proposed and the computational results are discussed.

  • PDF