• 제목/요약/키워드: Load Transient Response

검색결과 226건 처리시간 0.027초

수동필터를 이용한 고속전철 이선현상에 의한 전원외란 저감 (Reduction of Power Disturbance by Contact Loss Phenomenon of a High Speed Electric Train Using Passive Filters)

  • 장진영;진강환;강정남;박동규;김윤호
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.206-211
    • /
    • 2010
  • Since high-speed train is a dynamic load in which electric power is externally supplied, contact loss between the catenary and pantograph occurs. This phenomena including vibrations generates frequently irregular arcs, which, in turn causes EMI. Thus it is very important to develop the approach to reduce arc phenomenon by contact loss, as speed of electric railway vehicle increases. In case of an electric railway vehicle using electrical power, compared with diesel rolling stock, Power Line Disturbance(PLD) such as harmonics, transient voltage and current, Electromagnetic Interference(EMI), and dummy signal injection etc usually occur. In this study, the dynamic characteristics of a contact wire and a pantograph suppling electrical power to high-speed train are investigated with an electrical response point. To implement power line disturbance induced by contact loss phenomenon for high speed train operation, a hardware simulator which considers contact loss between contact wire and pantograph as well as contact wire deviation is developed. It is confirmed by the experiments that contact loss effect is largely dependent on voltage conditions when the contact loss occurs. Also, a passive filter is designed to reduce power disturbance and the designed system is verified by experiment.

압전적층판의 열-압전-탄성 동적 비선형 작동특성 (Thermopiezoelastic Nonlinear Dynamic Characteristics of Piezolaminated Plates)

  • 오일권
    • 한국소음진동공학회논문집
    • /
    • 제15권7호
    • /
    • pp.836-842
    • /
    • 2005
  • Nonlinear dynamic characteristics of active piezolaminated plates are investigated with respect to the thermopiezoelastic behaviors. For largely deformed structures with small strain, the incremental total Lagrangian formulation is presented based on the virtual work principles. A multi-field layer-wise finite shell element is proposed for assuring high accuracy and non-linearity of displacement, electric and thermal fields. For dynamic consideration of thermopiezoelastic snap-through phenomena, the implicit Newmark's scheme with the Newton-Raphson iteration is implemented for the transient response of various piezolaminated models with symmetric or eccentric active layers. The bifurcate thermal buckling of symmetric structural models is first investigated and the characteristics of piezoelectric active responses are studied for finding snap-through piezoelectric potentials and the load-path tracking map. The thermoelastic stable and unstable postbuckling, thermopiezoelastic snap-through phenomena with several attractors are proved using the nonlinear time responses for various initial conditions and damping loss factors. Present results show that thermopiezoelastic snap-through phenomena can result in the difficulty of buckling and postbuckling control of intelligent structures.

외란관측기 기반한 2 자유도 제어계의 설계 (Design of control system with two degrees of freedom based on the disturbance observer)

  • 하홍곤
    • 융합신호처리학회논문지
    • /
    • 제11권1호
    • /
    • pp.74-79
    • /
    • 2010
  • 많은 제어기법들이 제어계의 제어성능을 개선하기 위해 제안되고 있다. 제어계에서 제어에 대한 자유도는 독립적으로 조정할 수 있는 폐루프 전달함수의 수로 결정된다. 목표치 추종 및 외란억제에 대해 2자유도 제어기법이 많이 이용되고 있다. 본 논문에서는 외란을 제거하기 위해 외란관측기를 갖는 제어계를 2자유도 제어계로 변환시켰으며, 기동 및 부하변동 시 과도응답의 제거를 용이하게 하였다. 그리고 외란관측기의 설계법이 주파수 영역으로 제안하였으며, 이 방법으로 설계된 외란관측기를 이용하여 2자유도 제어계를 구성하였다. 시뮬레이션 결과를 통하여 제안한 알고리즘의 유효성을 확인 하였다.

Capacitive Coupling을 이용한 VFTO 측정계에 대한 고찰 (On the Considerations of VFTO Measuring Systems using by Capacitive Coupling)

  • 김진기;김민규;김영배;문인옥;김익수;이형호;김종연;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1520-1522
    • /
    • 1994
  • The clarification of insulation capability of GIS(Gas Insulated Substation) under very fast transient overvoltages such as disconnector/circuit-breaker induced surge is very important for establishing not only a rational insulation testing method, but also insulation design intending to make GIS more reliable and more minimized. One of the absolute prerequisits for this is that more accurate measurement of VFTO. This describes capacitive voltage measuring methods for high voltage steep-footed oscillating waves using capacitive coupling principle and their systems including source and load impedances. Time domain response of unit step and its frequency characteristics are also investigated.

  • PDF

2관성계의 부분적인 상태궤환을 갖는 $H_{\infty}$제어 (Partial State Feedback $H_{\infty}$ Control of Two-Mass System)

  • 한윤석;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권10호
    • /
    • pp.562-570
    • /
    • 1999
  • In the industrial motor drive system which is composed of a motor and load connected with a flexible shaft, a torsional vibration is often generated because of the elastic elements in torque transmission. This vibration, which is generated in a two-mass mechanical system. To solve this problem, recently there has been a lot of researches for the robust control relevant to the $H_{\infty}$ control suppressing the torsional vibration and rejecting the torque disturbance. In the case of the $H_{\infty}$controller, however, the command tracking property becomes worse because of overshoot during transient response. For this reason the $H_{\infty}$ controller, which includes the two-degrees-of-freedom(TDOF) controller, is designed in order to improve command tracking property. However, it also includes complexity realizing this controller. In this paper, a new $H_{\infty}$ controller with partial state feedback is proposed. Proposed $H_{\infty}$controller has simple structure but satisfies with the fast command tracking property and the attenuation of disturbances and vibrations simultaneously, just like the complicated TDOF $H_{\infty}$ controller.

  • PDF

동적전압보상기의 전압제어를 위한 PLL 방식의 개선 (Improvement of PLL Method for Voltage Control of Dynamic Voltage Restorer)

  • 김병섭;최종우
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.936-943
    • /
    • 2009
  • Dynamic voltage restorer(DVR) is now more preferable enhancement than other power quality enhancement in industry to reduce the impact of voltage faults, especially voltage sags to sensitive loads. The main controllers for DVR consists of PLL(phase locked loop), compensation voltage calculator and voltage compensator. PLL detects the voltage faults and phase. Compensation voltage calculator calculates the reference voltage from the source voltage and phase. With calculated compensation voltage from PLL, voltage compensator restores the source voltage. If PLL detect ideal phase, compensation voltage calculator calculates ideal compensation voltage. Therefore, PLL for DVR is very important. This paper proposes the new method of PLL in DVR. First, the power circuit of DVR system is analyzed in order to compensate the voltage sags. Based on the analysis, new PLL for improving transient response of DVR is proposed. The proposed method uses band rejection filter(BRF) at q-axis in synchronous flame. In order to calculate compensation voltage in commercial instruments, the PQR theory is used. Proposed PLL method is demonstrated through simulation using Matlab-Simulink and experiment, and by checking load voltage, confirms operation of the DVR

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한 연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;이진국
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.32-39
    • /
    • 2003
  • 동기발전기 출력전압은 여자시스템의 계자전류 제어에 의해 일정하게 유지된다. 고주파 PWM 컨버터(전류제어 모드 buck 컨버터) 형태의 여자시스템은 부하변동이 발생하였을 때 동기발전기의 계자전류를 제어하게 된다. 이 논문은 정상상태 및 과도상태에서의 안정화를 개선하기 위하여 여자시스템의 설계 및 실험에 대해 다루었다. 시뮬레이션 및 실험 결과는 제안된 여자시스템이 50[kW] 동기발전기의 DVR에 의해 응답시간이 개선되었음을 보여주었다.

철도차량용 스위치드 릴럭턴스 전동기의 설계 및 속도제어에 관한 연구 (A Study on the Design and Speed Control of the Switched Reluctance Motor for Railway Traction Application)

  • 조희;김경화
    • 한국철도학회논문집
    • /
    • 제15권3호
    • /
    • pp.237-243
    • /
    • 2012
  • 3차원 유한요소법을 이용하여 엔드코일 효과를 고려한 SRM의 자계해석을 수행하였다. 고정자 극 형상에 따른 자계특성의 비교를 통하여 제안된 형상에서 자계특성이 향상됨을 확인하였다. 해석한 자계특성을 적용하여 철도부하에 대한 PI 제어기와 슬라이딩모드 제어기의 속도제어를 수행하였다. 속도 제어 시뮬레이션은 Matlab-Simulink를 사용하여 구현되었으며 부하 가변 조건에서 슬라이딩모드 제어기가 PI 제어기에 비해 더 우수한 과도응답 및 정상상태응답을 나타냄을 확인하였다.

발전기 가속에너지를 이용한 고장파급방지장치 운전조건 완화용 전기저장장치 적정용량 산정방안 (Required Capacity Assessment of Energy Storage System for Relieving Operation Condition of SPS Using Generator Acceleration Energy)

  • 송승헌;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Due to the highly concentrated power plants integrated through the limited transmission lines in Korea, a Special Protection System(SPS) has been applied to stabilize the power systems by instantly tripping the pre-determined generators in a large-scaled power plant when a fault occurs on the drawing transmission lines. Moreover, power outputs of those generators are constrained to avoid any activation of Under Frequency Load Shedding(UFLS) even after those generators are tripped by SPS action. For this, this paper proposes a method for calculating the required capacity of Energy Storage System(ESS) expected to relieve the operating constraints to generators using its fast response for controlling power system frequency. The proposed method uses the generator acceleration energy to derive the stable condition during the SPS action. In addition, its effectiveness is verified by the case studies adopting actual SPS operations in Korean power systems.

Design-Oriented Stability of Outer Voltage Loop in Capacitor Current Controlled Buck Converters

  • Zhang, Xi;Zhang, Zhongwei;Bao, Bocheng;Bao, Han;Wu, Zhimin;Yao, Kaiwen;Wu, Jing
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.869-880
    • /
    • 2019
  • Due to the inherent feedforward of load current, capacitor current (CC) control shows a fast transient response that makes it suitable for the power supplies used in various portable electronic devices. However, considering the effect of the outer voltage loop, the stable range of the duty-cycle is significantly diminished in CC controlled buck converters. To investigate the stability effect of the outer voltage loop on buck converters, a CC controlled buck converter with a proportion-integral (PI) compensator is taken as an example, and its second-order discrete-time model is established. Based on this model, the instability caused by the duty-cycle is discussed with consideration of the outer voltage loop. Then the dynamical effects of the feedback gain of the PI compensator and the equivalent series resistance (ESR) of the output capacitor on the CC controlled buck converter with a PI compensator are studied. Furthermore, the design-oriented closed-loop stability criterion is derived. Finally, PSIM simulations and experimental results are supplied to verify the theoretical analyses.