• Title/Summary/Keyword: Load Stress Testing

Search Result 208, Processing Time 0.023 seconds

Influence of Repeated Loading, Alternation of Temperature and Initial Condition on the Change of Strizctural and Mechanical Characteristics of Alluvial Clayey Soil (반복하중,온도변화 및 초기조건이 충적점토의 구조변화와 역학적 특성에 미치는 영향)

  • 유능구;유영선;최중대;김기성
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.4
    • /
    • pp.69-79
    • /
    • 1992
  • To estimate soil behavior and structural characteristics under the conditions of cyclic loading, freezing & thawing and initial state, several testing was performed and obtained following results. 1.After repeated freezing and thawing processes, original soil structure was destroyed and changed to globular structure from honeycomb or tube in its structure types. Also above processes resulted increasing the soil compression strain while decreasing the failure stress in stress-strain relationship and reached the soil structure into the mode of brittle fracture. Under cyclic loading conditions, soil cluster which was originally dispersed structure colloided with each other, seperated, and finally the soil failed due to the effect of overcompaction. 2.Through the stabilization processes seperated by four steps, the structure of soil skeleton was changed to quite different globular type. The degree of compressibility of soil was decreased in the normally consolidated zone, while the strength against external load increased due to soil particle stabilization. 3.Soil stress-strain chracteristics were largely influenced by repeated up and down processes of temperature. The maximum deformation was obtained in the case of temperature between 0 10˚C by the reseon of particle cluster reformation. 4.Soil compressibility was largely influenced by the optimum moisture content. Under freezing process, swelling could be found and its magnitude was proportional to the density of soil. 5.Density of soil was decreased as increasing the number or repeated freezing and thawing processes and the largest decreasing rate was found at the first turning point from freezing to thawing cycle.

  • PDF

FATIGUE LIFE ESTIMATION OF IMPLANT USING A FINITE ELEMENT METHOD (유한요소법을 이용한 치아 임플랜트 피로수명 예측)

  • Han In-Sook;Son Jung-Hun;Yang Young-Soo;Lee Seung-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.414-420
    • /
    • 2006
  • Purpose : The purpose of this study is to use finite element analysis to predict the fatigue life of an implant system subjected to fatigue load by mastication (chewing force). The reliability and the stability of implant system can be defined in terms of the fatigue strength. Not only an implant is expensive but also it is almost impossible to correct after it is inserted. From a bio-engineering standpoint, the fatigue strength of the dental implant system must be evaluated by simulation (FEA). Material and Methods Finite element analysis and fatigue test are performed to estimate the fatigue strength of the implant system. Mesh of implant is generated with the actual shape and size. In this paper, the fatigue strength of implant system is estimated. U-fit (T. Strong, Korea, internal type). The stress field in implant is calculated by elastic-plastic finite element analysis. The equivalent fatigue stress, considering the contact and preload stretching of a screw by torque for tightening an abutment, is obtained by means of Sine's method. To evaluate the reliability of the calculated fatigue strength, fatigue test is performed. Results: A comparison of the calculated fatigue strength with experimental data showed the validity and accuracy of the proposed method. The initiation points of the fatigue failure in the implant system exist in the region of high equivalent fatigue stress values. Conclusion: The above proposed method for fatigue life estimation tan be applied to other configurations of the differently designed and improved implant. In order to prove reliability of prototype implant, fatigue test should be executed. The proposed method is economical for the prediction of fatigue life because fatigue testing, which is time consuming and precision-dependent, is not required.

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

Evaluation of the Degradation Trend of the Polyurethane Resilient Pad in the Rail Fastening System by Multi-stress Accelerated Degradation Test (복합가속열화시험을 통한 레일체결장치 폴리우레탄 탄성패드의 열화 경향 분석)

  • Sung, Deok-Yong;Park, Kwang-Hwa
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.466-472
    • /
    • 2013
  • The use of a concrete track is gradually growing in urban and high-speed railways in many part of the world. The resilient pad, which is essentially when concrete tracks are used, plays the important role of relieving the impact caused by train loads. The simple fatigue test[1] to estimate the variable stiffness of resilient pads is usually performed, but it differs depending on the practical conditions of different railways. In this study, the static stiffness levels of used resilient pads according to passing tonnages levels were measured in laboratory tests. Also, the simple fatigue test and the multi-stress accelerated degradation test for new resilient pads were performed in a laboratory. The static stiffness of the used pad was compared with the results of tests of usage times and cycles. The results of the comparison showed that the variable static stiffness levels of the used pad were similar to results of the multi-stress accelerated degradation test considering the fatigue and heat load. With a T-NT equation related to the degree of the multi-stress accelerated degradation, a model of multi-stress accelerated degradation for a resilient pad was devised. It was found through this effort that the total acceleration factor was approximately 2.62. Finally, this study proposes an equation for a multi-stress accelerated degradation model for polyurethane resilient pads.

Assessment of Left Ventricular Function with Echocardiography in Patients Treated with Adriamycin : A Load-Independent Index of Myocardial Contractility and Comparisons between Rest and Exercise (Adriamycin을 사용한 환아에서 심초음파를 이용한 좌심실 기능의 평가 : 심근 수축력의 부하 비의존족 지표 및 휴식시와 운동시의 비교)

  • Park, Pyoung Soo;Park, Hye Young;Lee, Hae Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.214-222
    • /
    • 2002
  • Purpose : The aim of this study was to evaluate myocardial injury in children treated with adriamycin by echocardiography, which is non-invasive and safe measurement for children. Methods : Left ventricular dimensions, wall stress, and contractile function were determined by echocardiographic methods in 17 patient recepients with adriamycin chemotherapy at rest(group 1) and during stress(group 2). Twenty age-matched normal subjects were established as control group. Results : End-diastolic dimension was decreased in both groups(group 1; $92{\pm}7%$ of normal, group 2; $87{\pm}8%$ of normal, P<0.05). Left ventricular end diastolic volume and wall mass were also decreased in both groups(group 1; $96{\pm}12mL/m^2$ and $145{\pm}18g/m^2$, group 2; $87{\pm}8mL/m^2$ and $137{\pm}16g/m^2$, respectively, P<0.05 and P<0.05) and group 2 showed lower values than group 1. Meridional end systolic stress(ESSm) was increased in both groups but there was no significant difference between the two groups(group 1; $52.6{\pm}6.2g/cm^2$, group 2; $63.5{\pm}8.5g/cm^2$, P<0.05, normal value $45.7{\pm}3.5g/cm^2$). The load-independent relation of rate-corrected circumferential fiber shortening velocity(Vcfc) to ESSm has a significant abnormal change in 7 out of 17(41%) in group 1 and 12 out of 17(71%) in group 2. Conclusion : The load-dependent systolic index, such as fractional shortening, may fail to show abnormality because of the compensatory changes in preload and afterload which can mask the impaired contractility. Therefore, systolic performance also should be monitored by a load-indepedent contractility index such as slope value of the end-systolic pressure-dimension relation and the position of the left ventricular stress-fiber shortening velocity after exercise.

Condition Evaluation of the Pavement Foundations Using Multi-load Level FWD Deflections (다단계 하중 FWD를 사용한 도로기초 상태평가 연구)

  • Park, Hee-Mun;Kim, Richard Y.;Park, Seong-Wan
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.261-271
    • /
    • 2003
  • A condition evaluation procedure for the pavement foundations using multi-load level Falling Weight Deflectometer(FWD) deflections is presented in this paper. A dynamic finite element program incorporating a stress-dependent material model, was used to generate the synthetic deflection database. Based on this synthetic database, the relationships between surface deflections and critical responses, such as stresses and strains in base and subgrade layers, have been established. FWD deflection data, Dynamic Cone Penetrometer(UP) data, and repeated load resilient modulus testing results used in developing this procedure were collected from the Long Term Pavement Performance (LTPP) and North Carolina Department of Transportation (NCDOT) database. Research effort focused on investigation of the effect of the FWD load level on the condition evaluation procedures. The results indicate that the proposed procedure can estimate the pavement foundation conditions. It is also found that structurally adjusted Base Damage Index (BDI) and Base Curvature Index (BCI) are good indicators for the prediction of stiffness characteristics of aggregate base and subgrade respectively. A FWD test with a load of 66.7 kN or less does not improve the accuracy of this procedure. Results from the study for the nonlinear behavior of a pavement foundations indicate that the deflection ratio obtained from multi-load level deflections can predict the type and quality of the pavement foundation materials.

Model Testing on the Behavior of Laterally Loaded Pile in NC Clay Soils (정규압밀 점토 지반에서 매입말뚝의 수평거동에 관한 모형 실험 연구)

  • Kim, Byeong-Tak;Lee, Sang-Ung;Kim, Yeong-Su
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.39-52
    • /
    • 1998
  • The pupose of the present paper is to estimate the effects of constraint condition of pile head, ground condition(dry unit weight. $\gamma_4$) and embedded pile lengths on the behavior of single pile which is embedded in normally consolidated clay. BBperiment functions can be quantified to these effects obtained from the results of model teats. The ground of model tests is normally consolidated( NC ) clay under three kinds of effective vertical stress. The results of the model tests using the steel pile of two different embedded pile length and of free-head and fired-head show that the lateral load-deflection relationship is to be elasto plastic behavior below $\gamma_d/\gamma_{dmax}$: 0.84 and that the reduction of lateral load of beyond maximum lateral load($Q_{max}$) at each model test is significantly time-dependent. In this study, it is shown that the displacement relationship can be fitted to exponential function of time by model best results. The effect of ground conditions on the ultimate and yield lateral load is fitted to exponential function including the ratio of dry unit weight to maximum dry unit weight. When tests by results are compared with those from Broms and Budhu et at., the predicted results are over-estimated about 27-87 ayo. In effectivity of constraint condition of pile head on the lateral load-deflection response, the $Q_{fixed}/Q_{gree}-y/D$ relationship is highly non-linear and fitted to parabolic function.

  • PDF

A Study on the Static Structural Strength Evaluation of 53ft Liquefied Natural Gas Tank Container (53ft 액화천연가스 탱크 컨테이너의 정적 구조 강도 평가에 관한 연구)

  • Chunsik Shim;Hokyung Kim;Daseul Jeong;Deokyeon Lee;Kangho Kim;Minsuk Kim;Sungkuk Wi;Heechang Noh;Youngbin Kwon;Changseok Hong;Kim Byeonghwa;Cheonghak Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.278-287
    • /
    • 2023
  • This study aims to analyze and evaluate the structural strength of a 53ft Liquefied Natural Gas (LNG) tank container according to International Organization for Standardization (ISO) 1496-3, amidst growing global demand for LNG transportation. The research was conducted in two main stages: structural analysis using Finite Element Analysis (FEA) under various load conditions, and structural strength tests following ISO 1496-3 test procedures. The structural analysis was performed considering different loading conditions to assess the structural safety of the tank container. Calculated stresses were compared with allowable stress under specified load conditions. The structural strength tests were conducted at Mokpo National University's Subsea Umbilical cable Riser Flowline R&D Center, which provided a suitable testing environment. The study found that calculated stresses met the allowable stress under specified load conditions, confirming the structural safety of the tank container. Additionally, the maximum deformation and permanent deformation satisfied the design criteria for all test cases, indicating the container's structural strength meets requirements. The research also contributed valuable data for future structural strength tests of similar products and facilitated the development of safe and efficient LNG transportation solutions by developing effective test procedures in accordance with ISO 1496-3 standards.

Accelerated Life Testing and Validity Evaluation of Finger Strips Used for Electromagnetic Shielding Doors (전자파 차폐 도어용 핑거 스트립의 가속수명시험 및 유효성 평가)

  • Lee, Joo Hong;Kim, Do Sik;Chang, Mu Seong;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.9
    • /
    • pp.831-837
    • /
    • 2015
  • Many persons and electronic devices are exposed to electromagnetic (EM) waves generated from magnetic resonance imaging (MRI) equipment, EM pulses (EMPs), and many other kinds of EM wave devices. Finger strips are used to provide shielding from these EM waves. Because of the high thermal conductivity of finger strips, they are used in the design of specialized doors that are installed in shielded rooms. In this study, we perform an accelerated life test using the load acceleration stress, which affects the main failure mode of finger strips. We predict the life of the finger strip under normal usage conditions based on the results of the accelerated life test. We compare the results with those predicted from the life test under normal usage conditions to evaluate the validity of accelerated life testing.

Time-Frequency Analysis of Dispersive Waves in Structural Members Under Impact Loads (시간-주차수 신호처리를 이용한 구조용 부재에서의 충격하중에 의한 분석 파동의 해석)

  • Jeong, H.;Kwon, I.B.;Choi, M.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.481-489
    • /
    • 2000
  • A time-frequency analysis method was developed to analyze the dispersive waves caused by impact loads in structural members such as beams and plates. Stress waves generated by ball drop and pencil lead break were recorded by ultrasonic transducers and acoustic emission (AE) sensors. Wavelet transform (WT) using Gabor function was employed to analyze the dispersive waves in the time-frequency domain, and then to find the arrival time of the waves as a function of frequency. The measured group velocities in the beam and the plate were compared with the predictions based on the Timoshenko beam theory and Rayleigh-Lamb frequency equations, respectively. The agreements were found to be very good.

  • PDF