• 제목/요약/키워드: Load Sensing

검색결과 284건 처리시간 0.023초

평판보를 이용한 6분력 로드셀 개발에 관한 연구 (Development of 6-component Load Cell Using Plate Beams)

  • 김갑순;이세헌;엄기원
    • 한국정밀공학회지
    • /
    • 제15권8호
    • /
    • pp.109-115
    • /
    • 1998
  • This paper describes the development of a 6-component load cell with plate beams which may be used to measure forces Fx, Fy, Fz and moments Mx, My, Mz simultaneously in industry. We have analyzed the bending strains on the surface of the beams under forces or moments by using Finite Element Method and designed the sensing elements of 6-component load cell. We have also determined the attachment location of strain gages of each load cell and fabricated 6-component load cell. To evaluate the rated strain and interference error of each load cell, we have carried out characteristic test of 6-component load cell.

  • PDF

SimulationX를 이용한 부하 감지형 메인 컨트롤밸브의 효율에 관한 연구 (A Study on the Efficiency of a Load Sensing Main Control Valve Using SimulationX)

  • 김동명;이정민;정원지;장주섭
    • 대한기계학회논문집A
    • /
    • 제40권1호
    • /
    • pp.87-95
    • /
    • 2016
  • 본 연구에서는 오픈센터 시스템과 부하 감지형 시스템의 해석모델을 개발하고 시스템의 특성과 효율을 분석하였다. 오픈 센터 방식의 메인 컨트롤 밸브의 압력과 유량 특성을 분석하기 위해 각각의 포트별로 시험을 수행하였다. 시스템의 특성 분석 전 단계에서 시험 결과와 해석 결과를 비교함으로써 해석모델의 신뢰성을 검토하였다. 신뢰성이 검증된 오픈 센터 방식의 메인컨트롤 밸브에 유량 분배 밸브를 추가하여 부하 감지형 메인 컨트롤 밸브의 해석모델을 개발하였다. 두 가지 시스템의 효율을 분석하기 위해 동일한 부하 조건에서 해석을 수행하였으며 각각의 부하 특성에 따른 효율을 검토하였다. 또한, 서로 다른 부하 조건에서 유량 분배 시스템의 특성을 분석함으로써 복합 동작에 대한 성능도 검토 하였다.

다중 작동기를 가진 부하감응 유압서보장치의 포화방지 알고리즘 (Anti-Saturation Algorithm for a Load Sensing Hydraulic Servo System with Multiple Actuators)

  • 이춘호;최필환;김철수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 추계학술대회 논문집
    • /
    • pp.977-981
    • /
    • 1996
  • A load sensing hydraulic system is widely used to military and commercial mobile applications fur its high running efficiency. Although concept and general control schemes are well known, the poor maneuverability of simultaneous multioperation of actuators still remains to be solved. In this paper, a new control algorithm is proposed to prevent the saturation of the system in such operating conditions, in which the total required flowrate of actuators may exceed the pump supply flowrate. The effectiveness of the proposed algorithm is verified through experiments.

  • PDF

A minimum energy control of a load-sensing hydraulic servo system

  • Kim, S.D.;Cho, H.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집(한일합동학술편); 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.747-752
    • /
    • 1987
  • The dynamic characteristics of a load-sensing hydraulic servo system are complex and highly unstable. Another property of the system is that the setting value of pump compensator is closely related to energy efficiency as well as control performance of the system. This necessitates the development of an effective control algorithm which guarantees good control performance, stability and energy efficiency. This paper considers a suboptimal PID control for the velocity control problem of the load-sensing hydraulic servo system. The results of simulations studies and experiments show that the proposed suboptimal controller can produce much better control performance than nonoptimal controllers and give effective energy efficiency.

  • PDF

Agent-Based Load Balancing Method for Web GIS Services; Web-Based Forest Fire Management System

  • Jo, Yun-Won;Jo, Myung-Hee;Oh, Jeong-Soo
    • 대한원격탐사학회지
    • /
    • 제17권4호
    • /
    • pp.359-368
    • /
    • 2001
  • The prototype of forest fire management system on Web was studied. In the architecture of this system, one of the most important concerns is to handle load upcoming to Web Server so that it provides Web service without any delay or failure. In order to solve this problem, the agent is designed on dispatcher in a Web server cluster and implemented to distribute load dynamically by considering the information related to load coming to the Web Server such as the number of connection to the Map Server. The proposed forest fire management system has user-friendly interface with the GIS mapping functionality by selecting Map Objects Internet Map Server (MO IMS) as Map Server and is implemented using Java as programming language.

대용량 Compact형 로드셀의 기둥형 감지부 설계 및 해석 (Design and Analysis of Column Type Sensing Element for Large Compact Load Cell)

  • 강대임;신홍호;김종호;박연규
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.601-607
    • /
    • 2003
  • The column type is used as the sensing element of the load cell to measure the large force in the range of 10$^4$~ 10$^{7}$ N. However. it is not easy to handle the load with large capacity due to its size. It is, therefore, necessary to design a compact load cell with a low aspect ratio. Thus this paper showed the characteristic evaluation of compact load cell with respect to the shape of supporting plate. The supporting plate of the load cell was an annular type with inner(D$_{i}$) and outer(D$_{o}$) diameters. Using the strain distribution obtained from FEM. the supporting plate was designed to get the stable output voltage of the load cell. The three designed supporting plates were manufactured, and the result of characteristic experiment of the load cell, using the 10 MN hydraulic force standard machine, was compared with FEM.M.M.

A High Voltage, High Side Current Sensing Boost Converter

  • Choi, Moonho;Kim, Jaewoon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.36-37
    • /
    • 2013
  • This paper presents high voltage operation sensing boost converter with high side current. Proposed topology has three functions which are high voltage driving, high side current sensing and low voltage boost controller. High voltage gate driving block provides LED dimming function and switch function such as a load switch of LED driver. To protect abnormal fault and burn out of LED bar, it is applied high side current sensing method with high voltage driver. This proposed configuration of boost converter shows the effectiveness capability to LED driver through measurement results.

  • PDF

Electro-Micromechanical 시험법을 이용한 Ni Nanowire Strands 및 Carbon Nanotube 강화 에폭시 복합재료의 비파괴 감지능 평가 (Nondestructive Sensing Evaluation of Ni Nanowire Strands and Carbon Nanotube/Epoxy Composites Using Electro-Micromechanical Techniques)

  • 정진규;김성주;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.269-272
    • /
    • 2005
  • Nondestructive damage sensing and load transferring mechanism of Ni nanowire strands and multi-wall carbon nanotube (MWCNT)/epoxy composites were investigated using electro-micromechanical techniques. MWCNT composite was especially prepared for high volume contents, 50 vol % of reinforcement. Electro-micromechanical techniques were applied to measure apparent modulus and contact resistance of Ni nanocomposites with their alignment and different diameters, and adding contents. Applied cyclic load affected on apparent modulus and electrical properties on nanocomposites due to various inherent properties of each CNMs. Contact resistivity on humidity sensing was a good indicator for monitoring as for multifunctional applications. Further study on actuation as well as sensing will be investigated for the following work continuously.

  • PDF

Broad and stage-based sensing function of HCFRP sensors

  • Wu, Z.S.;Yang, C.Q.
    • Smart Structures and Systems
    • /
    • 제3권2호
    • /
    • pp.133-146
    • /
    • 2007
  • This paper addresses a new type of broad and stage-based hybrid carbon fiber reinforced polymer (HCFRP) sensor that is suitable for the sensing of infrastructures. The HCFRP sensors, a type of composite sensor, are fabricated with three types of carbon tows of different strength and moduli. For all of the specimens, the active materials are carbon tows by virtue of their electrical conductivity and piezoresistivity. The measurement principles are based on the micro- and macro-fractures of different types of carbon tows. A series of experiments are carried out to investigate the sensing performances of the HCFRP sensors. The main variables include the stack order and volume fractions of different types of carbon tows. It is shown that the change in electrical resistance is in direct proportion to the strain/load in low strain ranges. However, the fractional change in electrical resistance (${\Delta}R/R_0$) is smaller than 2% prior to the macrofractures of carbon tows. In order to improve the resistance changes, measures are taken that can enhance the values of ${\Delta}R/R_0$ by more than 2 times during low strain ranges. In high strain ranges, the electrical resistance changes markedly with strain/load in a step-wise manner due to the gradual ruptures of different types of carbon tows at different strain amplitudes. The values of ${\Delta}R/R_0$ due to the fracture of high modulus carbon tows are larger than 36%. Thus, it is demonstrated that the HCFRP sensors have a broad and stage-based sensing capability.

자기감지형 보수재로 단면증타된 콘크리트 부재의 역학 및 전기적 특성 (Mechanical and Electrical Characteristics of Concrete Members Enlarged with Self-Sensing Cementitious Materials for Repair)

  • 이건철;임건우;임창민;홍성원;김영민
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권5호
    • /
    • pp.139-146
    • /
    • 2023
  • In this study, compressive strength and adhesion strength were measured as repair materials to evaluate the mechanical and electrical properties of compression and shear specimens with self-sensing repair materials. As a result of the experiment, the strength improvement rate of the compression test specimen was higher than the section enlargement area ratio, but the shear test specimen did not show an improvement in strength as much as the section enlargement area ratio. Compression experiments under load showed high correlation between FCR-Strain and FCR-Stress, confirming self-sensing performance. However, the shear test did not show as much correlation as the compression test. Accordingly, it is judged that the self-sensing repair material is suitable for the compression member on which the compression load acts in the building.