• Title/Summary/Keyword: Load Reducing

Search Result 1,082, Processing Time 0.031 seconds

The Development of Intelligent Direct Load Control System

  • Choi, Sang Yule
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.103-108
    • /
    • 2015
  • The electric utility has the responsibility of reducing the impact of peaks on electricity demand and related costs. Therefore, they have introduced Direct Load Control System (DLCS) to automate the external control of shedding customer load that it controls. Since the number of customer load participating in the DLC program are keep increasing, DLCS operators a re facing difficulty in monitoring and controlling customer load. The existing DLCS needs constant operator intervention, e.g., whenever the load is about to exceed a predefined amount, it needs operator's intervention to control the on/off status of the load. Therefore, DLCS operators need the state-of-the-art DLCS, which can control automatically the on/off status of the customer load without intervention as much as possible. This paper presents an intelligent DLCS using the active database. The proposed DLCS is applying the active database to DLCS which can avoid operator's intervention as much as possible. To demonstrate the validity of the proposed system, variable production rules and intelligent demand controller are presented.

A Scheme for Reducing Load Forecast Error During Weekends Near Typhoon Hit (태풍 발생 인접 주말의 수요예측 오차 감소 방안)

  • Park, Jeong-Do;Song, Kyung-Bin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1700-1705
    • /
    • 2009
  • In general, short term load forecasting is based on the periodical load pattern during a day or a week. Therefore, the conventional methods do not expose stable performance to every day during a year. Especially for anomalous weather conditions such as typhoons, the methods have a tendency to show the conspicuous accuracy deterioration. Furthermore, the tendency raises the reliability and stability problems of the conventional load forecast. In this study, a new load forecasting method is proposed in order to increase the accuracy of the forecast result in case of anomalous weather conditions such as typhoons. For irregular weather conditions, the sensitivity between temperature and daily load is used to improve the accuracy of the load forecast. The proposed method was tested with the actual load profiles during 14 years, which shows that the suggested scheme considerably improves the accuracy of the load forecast results.

A Study on the Reduction effect of Peak Cooling Load on the Sunshade effect of BIPV System (BIPV 시스템의 차양 효과에 따른 피크 냉방부하 절감효과에 관한 연구)

  • Lee, Chung-Sik;Lee, Eung-Jik;Lee, Chul-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.14-20
    • /
    • 2008
  • As the number of buildings that use the transparent permeation materials as the outer wall is on the increase, the coming amount of the light rays is a lot, and thus the increase in the cooling load and the radiant heat of high temperature may cause the residents to discomfort. In order to reduce such influences, this paper analyzed the installation effects of the sunshade BIPV. The inner temperature of the room installed the sunshade BIPV or otherwise was measured, and compared and analyzed the effects of reducing the cooling load by the incoming light rays. The sample space of the third floor of S university installed the sunshade BIPV has two rooms on the same conditions, and for five sunny days selected in August, the researcher measured the air temperature and the temperature of the fittings with closing the windows to minimize the movement of air without operating the coolers. The maximum cooling load measured by the incoming light rays in the room where the sunshade BIPV was not installed was examined as 459.13kcal/h. It can be understood as the effect of reducing the cooling load according to the incoming rays of the room with sunshade BIPV. Even though the effect of cooling load reduction is not so great in a room, the total reduction in cooling room for the 32 rooms installed the sunshade BIPV was estimated to be 40442.27kcal/day, which will be able to bring the maximum reduction effect of 17.1kW in energy and reduce the investment cost owing to the reduction in cooling load when initially designing the building.

An Analytical Study on the Change of System Supports according to the Brace Installation (가새 설치 여부에 따른 시스템 동바리 거동변화에 대한 해석적 연구)

  • Oh, Byoung-Han;Choi, Byong J.
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.104-111
    • /
    • 2018
  • System supports are widely used in concrete construction due to the convenience and structural safety at the point of both installation and dismantling. However, there were frequent collapses in the construction sites due to the absence of both structural review and brace installations. Therefore, this paper examines the importance of braces in the system supports. In order to examine the importance of the brace, four types of braces were considered: 100% braces, 50% braces, 25% braces, and without braces. The maximum displacement of the 100% braced model was 0.97 mm, the 50% braced model was 1.13 mm, the 25% braced model was 1.16 mm and the non-braced model was 24.3 mm, respectively. Compared to the model with the without-braces, the model with 100% of the braces installed has a displacement of 4.0%, the model with 50% of the braces showed a displacement of 4.7%, and the model with 25% of the braces appeared to be a displacement of 4.8%. That is, the installation of the braces is effective in reducing the maximum displacement of the system supports and is effective in reducing the maximum displacement with only small number of braces installed.

Effects of Combined Sewer Overflows According to Drainage Basin Types (유역형상에 따른 합류식 하수도의 월류부하량 추정)

  • Lee, Cheol-Kyu;Hyun, In-Hwan;Jeong, Jeong-Youl;Shim, Jae-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.21-26
    • /
    • 2004
  • It is muck important to determine the intercepting capacities as measures for reducing the load of contamination influenced by CSOs during wet weather period. Intercepting and treating the whole rainfalls can be best measured for reducing the contamination load, but it is not desirable in view of scale and preservation of the wastewater treatment facilities. This study analyzed the quantity and quality of the water in the combined sewer by method of changing the type and size of drainage basin and intercepting capacities in rainfalls, estimate the influence the other CSOs at the change of planned intercepted quantity, and compared the degree of contamination load between the combined system and separate system by examining the influence of the other CSOs at the change of planned intercepted quantity.

A Stochastic Pplanning Method for Semand-side Management Program based on Load Forecasting with the Volatility of Temperature (온도변동성을 고려한 전력수요예측 기반의 확률론적 수요관리량 추정 방법)

  • Wi, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.852-856
    • /
    • 2015
  • Demand side management (DSM) program has been frequently used for reducing the system peak load because it gives utilities and independent system operator (ISO) a convenient way to control and change amount of electric usage of end-use customer. Planning and operating methods are needed to efficiently manage a DSM program. This paper presents a planning method for DSM program. A planning method for DSM program should include an electric load forecasting, because this is the most important factor in determining how much to reduce electric load. In this paper, load forecasting with the temperature stochastic modeling and the sensitivity to temperature of the electric load is used for improving load forecasting accuracy. The proposed planning method can also estimate the required day, hour and total capacity of DSM program using Monte-Carlo simulation. The results of case studies are presented to show the effectiveness of the proposed planning method.

Pole Assignment for Structural Active Control

  • Vongchavalitkul, Sanguan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.5-7
    • /
    • 2004
  • Significant progress has been achieved in the active control of civil-engineering structures, not only in the control algorithm, but also in control testing of the scaled model and full-scale building. At the present time, most algorithms used in the active control of civil engineering structures are based on the various active control techniques. In this paper represents active control method, by using pole assignment for reducing structural vibration under excited load. Numerical simulations are performed to assess the effectiveness of pole assignment control system. The relative displacement of structure system is significantly reduced.

  • PDF

The switching algorithm of MAP load balacing on HMIPv6 (HMIPv6(Hierachical Mobile IPv6 Mobility Management)상에서의 MAP과 이동노드(Mobile Node)의 Load-Balancing 을 위한 스위칭(Switching) 알고리즘 연구)

  • Sung, Ki-Hyuk;Yoo, Byung-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.209-210
    • /
    • 2006
  • Hierachical Mobile IPv6 (HMIPv6) solves Micro-mobility protocol problem about Handover. Mobility Anchor Point(MAP) helps reducing the handover, but this makes a load on the MAP. Besides the MAP operates this work everytime, and every Nodes. In this paper, we propose the algorithm that reduces the amount of Map working.

  • PDF