• Title/Summary/Keyword: Load Out

Search Result 4,872, Processing Time 0.035 seconds

Finite Element Analysis of Cracted Structural Steel Member (균열을 가진 강구조부재의 한계하중에 대한 유한요소해석)

  • 박용걸
    • Computational Structural Engineering
    • /
    • v.8 no.1
    • /
    • pp.123-126
    • /
    • 1995
  • The purpose of the analysis is the numerical simulation of structures strained to the limit loads. The finite element calculations and experiments with cracked structures have been carried out yielding over limit strains between 10% and 15% by single peak load. Load versus displacement-diagrams and J-diagrams up to the limit load are calculated. By this way the influence of geometric parameters may be assessed in the post yield region. It is proposed to use such calculations to correlate experiments carried out with small specimens to experiments simulating the true dimensions of the design structure.

  • PDF

The effects of Load of Hydraulic Oil on Hydraulic Mechanism (유압유 부하가 유압기계에 미치는 영향)

  • 박주석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.72-74
    • /
    • 1998
  • The adaptive skill of the human operator is now being simulated and reproduced by computer that have become more powerful and less expensive. This paper is concerned with an investigation of the effects of dynamic load of hydraulic oil on pressures with three different circuit(meter-in, meter-out and bleed-off). The experimental results showed that pressures increase with an increase in dynamic load in bleed-off circuit, but there is no variation of pressure in meter-in and meter-out circuits.

  • PDF

A Laborratory Study of the Fatigue and Development of Analysis Program of Concrete Pavements (시멘트 콘크리트 포장의 피로실험과 프로그램 작성)

  • 엄주용;임승욱;윤기용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.232-240
    • /
    • 1996
  • In the present study, a series of static load test and fatigue test were carried out to investigate the behavior of the CRCP. The specimens were sized to 25% of real one lane CRCP. The fatigue tests were carried out for the repetitive load as much as 16%, 39%, 40%, 48%, 59% and 78% of the max. static load for the center or corner loading. Compared the field test with laboratory test for FWD, it is an equpment useful to maintance and manage of the concrete pavements.

  • PDF

Experimental Study of Cushioning Pneumatic Cylinder with Meter In/Meter Out Control System (메타인 및 메타아웃 제어에 의한 공기압 실린더의 쿠션특성에 관한 실험적 연구)

  • 김동수;이상천
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.2
    • /
    • pp.97-104
    • /
    • 2000
  • Pneumatic cylinder is widely used for mechanical handling systems. Often, the impact occurs at the both ends points of pneumatic cylinder and generates destructive shock with in the structural operating members of the machine or equipment. To reduce the damage of system, therefore, shock absorbing devices are required. Cushioning of pneumatic cylinders at one or both ends of piston stroke is used to reduce the shock and vibration. The cylinder body have to withstand under high velocity and load. In this research, the pneumatic cushioning cylinder moving tests have been conducted for different load mass and supply pressure. The velocity of pneumatic cylinder actuation system with multiple orifice cushion sleeve which is set vertically controled with meter-in/out system. This study examines the dynamic characteristics of pneumatic cylinder with cushion devices. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion region characteristics was also revealed in the meter-in system.

  • PDF

A study on case analysis for loading capacity standard establishment of bi-directional pile load test (BD PLT) (양방향말뚝재하시험의 재하용량 기준 설정을 위한 사례분석 연구)

  • Choi, Yong-Kyu;Seo, Jeong-Hae;Kim, Sang-Il
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.377-384
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load test of Mega foundation, loading capacity specification were not specified exactly. Therefore there are so many confusions and variations of maximum 2 times in loading capacity are come out. In this study, specifications of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio and sufficiency ratio of design load were analyzed. It can be known that the loading capacity specification of bi-directional pile load test must be defined as 1-directional test load that is established as more than 2 times of design load.

  • PDF

A study on the part-load performance of 2-stage water source heat pump (2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구)

  • Lee, Young-Soo;Baik, Young-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF

Measurement and Analysis of Voltage Drop in Traction Power Supply System (전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석)

  • Kim, Joo-Rak;Lee, Young-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

Numerical Modelling of Reinforced Soil Slopes Under Railway Load (열차하중을 받는 토목섬유 보강사면의 수치해석)

  • Jung, Young-Hoon;Lee, Il-Wha;Jang, Ki-Soo;Yoo, Seung-Joon;Lee, Su-Hyung
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.753-760
    • /
    • 2006
  • This paper presents the procedure and results of the numerical modelling that was carried out to investigate the stability of reinforced soil slopes under dynamic railway load. The two-dimensional explicit dynamic finite element method (ABACUS) was used to carry out the numerical analyses. To simulate the railway load, the top surface of the embankment was excited by the uniform distributed load whose frequency and magnitude was estimated by the measured railway acceleration during train passing. The embankment displacements and geogrid axial forces were analyzed to evaluate the stability of reinforced soil slopes under the dynamic train load.

Analysis on the Load Carrying Capacity of Steel Bridges Considering Initial Stress (강교의 초기응력을 고려한 내하력 해석)

  • Chang, Kyong-Ho;Kang, Jae-Hoon;Jang, Gab-Chul
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.4 s.14
    • /
    • pp.129-136
    • /
    • 2004
  • Almost the steel bridges are manufactured and constructed by using weld process. The welding is necessary for connecting the flange, web and stiffener of steel bridges. However, residual stress and welding deformation producted by welding is a causes of decreasing the load carrying capacity of steel bridges. therefore, it is need to consider the initial stresses by welding when design the steel bridge. However, the influence of initial stress producted by welding on load carrying capacity of steel bridges is not elucidated. In this paper, the initial stress state on the flange, web and stiffener of steel bridges are clarified by carrying out 3-dimensional non-steady heat conduction analysis and 3-dimensional thermal elastic-plastic analysis. The influence of initial stress by welding on load carrying capacity of steel bridges is clarified by carrying out 3-dimensional elastic-plastic finite element analysis using finite deformation theory.

  • PDF

A Study on Cyclic Bending Load of Bus Folding Door Pillar including Adhesive Bonding and Spot Welding (접착제 접합과 점용접된 버스 폴딩도어 필러의 굽힘피로강도 평가에 관한 연구)

  • Yoon Ho-Chel
    • Journal of Welding and Joining
    • /
    • v.24 no.3
    • /
    • pp.55-59
    • /
    • 2006
  • This paper is concerned with a study on cyclic bending load of bus folding door pillar including adhesive bonding and spot welding. Three specimen types were used such as spot welding, I-type adhesive bonding and M-type adhesive bonding in this study. The tensile-shear tests were carried out to evaluate the tensile-shear strength of these three specimen types. Also four-point bending tests were carried out to evaluate the static and dynamic bending load. From the results, using adhesive bonding has a better effect on the static and dynamic bending load than using spot welding. Therefore, manufacturing better structural products can be expected by applying hybrid welding using adhesive and spot welding to those.