• 제목/요약/키워드: Load Losses

검색결과 361건 처리시간 0.021초

공동주택 변압기용량 적정 산정을 위한 수용률 개선 및 사례 연구를 통한 경제성 평가 (The Study on Estimation of The Transformer Capacity of Housing and Economic Evaluation Using Case Studies)

  • 이윤상;서정열;신희상;조성민;김재철
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.142-149
    • /
    • 2010
  • Interest in energy efficiency and savings have been rising internationally. For this reason, the domestic housing construction in the area of power equipment is being actively studied. Currently approximately 400,000 per year of domestic housing is being built. Applies to housing construction during the current transformer capacity low utilization and load factor has been applied has been designed. In other words, excessively high reserve capacity has been applied. According to this problem, initial facility costs and power losses will cause because transformer low utilization be appropriated. Thus, the energy efficiency drops. In this paper, analysis of past utilization of the housing transformer, and applying an appropriate demand factor has been analyzing the energy loss reduction. this analysis of current domestic conditions for the proper housing transformer scheme is to calculate the capacity.

A New LLC Resonant Converter with Multiple Outputs for High Efficiency and Low Cost PDP Power Module

  • Kim, Chong-Eun;Yi, Kang-Hyun;Moon, Gun-Woo;Lee, Buem-Joo;Kim, Sang-Man
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.439-441
    • /
    • 2005
  • A new LLC resonant converter with multiple outputs is proposed for high efficiency and low cost plasma display panel (PDP) power module. In the proposed converter, ZVS turn-on of the primary MOSFETs and ZCS nun-off of the secondary diodes are guaranteed in the overall input voltage and output load range. Moreover, the primary MOSFETs and the secondary diodes have low voltage stresses clamped to input and the output voltage, respectively. Therefore, the proposed converter shows the high efficiency due to the minimized switching and conduction losses. In addition, by employing the transformer, which has the two and more secondary side, the proposed converter can have multiple outputs and they show the great cross-regulation characteristics. As a result, the proposed converter can be implemented with low cost and compact size. The 500W prototype is implemented, which integrates the sustaining and addressing power supplies of PDP power module. The maximum efficiency is 96.8% and the respective output voltages are well regulated. Therefore, the proposed converter is suitable for high efficiency and low cost PDP power module.

  • PDF

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

ATM 통신망에서의 지연 및 손실 우선순위를 갖는 다중화 알고리즘의 성능 평가 (Performance Evaluation of Multiplexing Algorithms with Both Delay and Loss Priorities in ATM Networks)

  • 전용희
    • 한국통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.842-856
    • /
    • 1994
  • 광대역 종합정보 통신망 (B-ISDN)이 수용할 여러 서비스들은 다양한 지연, 지연 변화 및 셀 손실 확률 요구 사항을 가지고 있다. B-ISDN을 위한 적절한 제어 방법의 설계는 매우 중요하고 어려운 문제이다. 본 논문에서는, 그러한 다양한 요구사항을 만족하기 위하여, 지연 및 손실 우선 순위 모두를 가진 다종화 알고리즘을 제안한다. 손실 우선 순위의 구현을 위하여, 음성 셀은 폐기 불가한 셀(즉, 높은 우선 순위의 셀) 및 폐기 가능한 셀(즉, 낮은 우선 순위의 셀)로 생성됨을 가정하였다. 낮은 순위의 음성셀은 통신망내에서 혼잡이 발생하면 폐기될 수 있다. 본 셀 탈락 방법은 음성 및 데이터의 지연뿐만 아니라 셀 손실도 감소 시키는 것을 보여주고 있다. 이러한 부하 감소 방법은 광대역 종합정보 통신망의 이용율을 크게 개선 시킬 수 있을 것으로 기대된다.

  • PDF

STATCOM을 이용한 고속전철 부하가 연계된 계통의 안정도 향상에 관한 연구 (A Study on System Stability Improvement of Power System with High Speed Electric Railway Using STATCOM)

  • 이준경;오재경;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.625-631
    • /
    • 2003
  • The purpose of this paper is to assess experimentally system stability of the 154 ㎸ transmission system due to the current of the forthcoming AC High-Speed Railway (HSR) era. It introduces a simple method to evaluate the system stability The proposed method also shows the relationship between stability and power losses, and the stability indices made by the numerical process proposed in this paper will be used to assess whether a system can be stabilized or not. This paper also presents the improvement of the stability via loss reduction using STATCOM. Reactive power compensation is often the most effective way to improve both power transfer capability and system stability. The suitable modeling of the electric railway system should be applicable to the PSS/E. In the case study the proposed method is tested on a practical system of the Korea Electric Power Corporation (KEPCO) which will be expected to accommodate the heavy HSR load. Furthermore, it prove that the compensation of voltage drop and its by-product, loss reduction is closely related to improvement of system stability.

Life-cycle-cost optimization for the wind load design of tall buildings equipped with TMDs

  • Venanzi, Ilaria;Ierimonti, Laura;Caracoglia, Luca
    • Wind and Structures
    • /
    • 제30권4호
    • /
    • pp.379-392
    • /
    • 2020
  • The paper presents a Life-Cycle Cost-based optimization framework for wind-excited tall buildings equipped with Tuned Mass Dampers (TMDs). The objective is to minimize the Life-Cycle Cost that comprises initial costs of the structure, the control system and costs related to repair, maintenance and downtime over the building's lifetime. The integrated optimization of structural sections and mass ratio of the TMDs is carried out, leading to a set of Pareto optimal solutions. The main advantage of the proposed methodology is that, differently from the traditional optimal design approach, it allows to perform the unified design of both the structure and the control system in a Life Cycle Cost Analysis framework. The procedure quantifies wind-induced losses, related to structural and nonstructural damage, considering the stochastic nature of the loads (wind velocity and direction), the specificity of the structural modeling (e.g., non-shear-type vibration modes and torsional effects) and the presence of the TMDs. Both serviceability and ultimate limit states related to the structure and the TMDs' damage are adopted for the computation of repair costs. The application to a case study tall building allows to demonstrate the efficiency of the procedure for the integrated design of the structure and the control system.

High Efficiency Drive of Dual Inverter Driven SPMSM with Parallel Split Stator

  • Lee, Yongjae;Ha, Jung-Ik
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.216-224
    • /
    • 2013
  • This paper describes dual inverter drive for a fractional-slot concentrated winding permanent magnet synchronous machine (PMSM). PMSMs are widely used in many applications from small servo motors to few megawatts generators thanks to its high efficiency and torque density. Especially, fractional-slot concentrated winding PMSM is very popular in the applications where wide operation range is required because it shows very wide constant power speed ratios. High speed operation, however, requires lots of negative daxis current for reducing back-EMF regardless of output torque. Field weakening current does not contribute to the torque generation in surface mounted PMSM case and causes inverter and copper loss. To reduce the losses from field weakening current, this paper proposes PMSM with split stator and parallel dual inverter drive. Proposed parallel dual inverter drive reduces back-EMF and enables efficient drive at high speed and light load situation. Control strategy of proposed dual inverter system is established through loss analysis and simulation. Proposed concept is verified with practical experiment.

컴퓨터기반의 DAS를 적용한 태양광 조명설비의 운용패턴 고찰 (Load Pattern Considerations of The Photovoltaic Lighting System by Using Computer-based Date Acquisition System)

  • 황명근;허창수
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.1-10
    • /
    • 2003
  • 옥외 조명 시스템의 응용으로 두 가지 태양광설비(PV) 조명방식에 저압나트륨 램프(low pressure sodium: LPS)와 무전극 램프(electrodeless lamp)를 부하로 한 조명설비 시스템을 설계·제작·설치하며, 전지 수명을 고려한 감시 목적으로 데이터 수집에 유효한 랩뷰(Labview) 프로그램을 사용하였다. 설치된 PV 시스템에서 태양전지 배열로부터 만들어진 전원 및 그것의 최대 출력에 비교된 에너지 손실을 실험하였고, PV 시스템 개체구성 요소들의 성능을 관찰하였으며, 설치된 PV 조명방식들의 성능을 분석한 후, 태양전지 배열 음량을 줄이는 가능성에 대한 태양광 조명설비 동작특성에 대해 고찰하였다.

뉴로퍼지 제어기를 이용한 고주파 유도 가열기의 시변부하에 대한 정전력 제어 (The power regulation of a High-Frequency Induction Heating System with time variance load using a neural fuzzy controller)

  • 장종승;김승철;임영도
    • 한국정보통신학회논문지
    • /
    • 제2권2호
    • /
    • pp.223-230
    • /
    • 1998
  • 본 논문은 뉴랄퍼지를 이용한 디지탈식 제어기를 고주파 유도 가열기의 전력 조절을 위해 IGBT를 사용한 위상 전이(Phase-Shift) 펄스폭 변조(PWM)와 펄스 주파수 변조(PFM)가 조절되는 공진 고주파 인버터를 응용한 유도가열기를 설명한다. 이는 실제로 산업 현장에서 20KHz~500KHz 유도 가열 및 유도 용해 전원 장치용으로 쓰인다. 위상 전이(Phase-Shift) PWM 정전력 조절 기술을 바탕으로 한 적응 주파수 추종 기법은 스위칭 손실을 최소화하고 전력조절을 용이하게 하기 위해 소개되어졌다. IGBT를 사용하여 실험적으로 만들어진 실험장치는 성공적으로 논증과 토의가 되어졌다.

  • PDF

UPFC Device: Optimal Location and Parameter Setting to Reduce Losses in Electric-Power Systems Using a Genetic-algorithm Method

  • Mezaache, Mohamed;Chikhi, Khaled;Fetha, Cherif
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 2016
  • Ensuring the secure operation of power systems has become an important and critical matter during the present time, along with the development of large, complex and load-increasing systems. Security constraints such as the thermal limits of transmission lines and bus-voltage limits must be satisfied under all of a system’s operational conditions. An alternative solution to improve the security of a power system is the employment of Flexible Alternating-Current Transmission Systems (FACTS). FACTS devices can reduce the flows of heavily loaded lines, maintain the bus voltages at desired levels, and improve the stability of a power network. The Unified Power Flow Controller (UPFC) is a versatile FACTS device that can independently or simultaneously control the active power, the reactive power and the bus voltage; however, to achieve such functionality, it is very important to determine the optimal location of the UPFC device, with the appropriate parameter setting, in the power system. In this paper, a genetic algorithm (GA) method is applied to determine the optimal location of the UPFC device in a network for the enhancement of the power-system loadability and the minimization of the active power loss in the transmission line. To verify our approach, simulations were performed on the IEEE 14 Bus, 30 Bus, and 57 Bus test systems. The proposed work was implemented in the MATLAB platform.