• Title/Summary/Keyword: Load Losses

Search Result 361, Processing Time 0.032 seconds

A Study on Loss Analysis of ZVT-PWM Boost Converter using Quasi-Resonant Technique (유사공진 기술을 이용한 ZVT-PWM Boost 컨버터의 손실분석에 관한 연구)

  • 김정래;박경수;성원기;김춘삼
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Recently, DC-DC converters significantly increase the total losses as rising switching frequency. Trnditional soft switching technique for reducing switching losses even increase voltage/Clment stress of switch In this paper, Resonant circuit for soft switching is connected in parallel with power stage and only operates just before tum-on of the main sWItch. Therefore, ills doesn't affect the total circuit QI'||'&'||'pound;ration. The object of tIns paper is to make the linearized equivalent loss mxleIs. and to analyze the total losses by experiment. ZVT-PWlvI converter designed with 170-260[V] input, 400[V] 5[A] output, and 100[kHz] switching frequency is tested respectively with 500[W], 1[kW], 1.5[kW], and 2[kW] loads. The total losses in input 220[V], 2[kW] load are analyzed by usirm the linearized equivalent loss models.

  • PDF

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

Structural Analysis of Underground Parking Garage Under Vehicle Load (지하주차장 차량하중에 따른 구조체의 영향분석)

  • Kim, Young-Jin;Lee, Bum-Sick;Choi, Dong-Sub;Oh, Hyo-Keon;Kang, Chang-Bum
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.22-29
    • /
    • 2013
  • Accumulation of more than 20,000,000 vehicles since the establishment of the quality of life and economic development needs several parking lots and cause crack problem in Korea. Related structures in large cities due to the lack of parking garage attached to secure underground parking structures are actively being built, and the basement parking lot will continue to increase more stories and the trend is expected to be larger. But so far, construction of the underground parking structure is related to a number of problems, including cracks in the structure. Therefore, in this study, repair, reinforcement and a few non-economic losses in the current design criteria are presented. The review of the structure used to current design criteria is to minimize crack and maximize usability.

Reliability Improvement Considering Effect of Dispersed Generator and Interruption Cost in Distribution Systems (분산전원의 영향과 정전비용을 고려한 신뢰도 향상)

  • Kim, Kyu-Ho;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.172-177
    • /
    • 2006
  • This paper presents a method to improve reliability considering dispersed generator(DG) installation and interruption cost with load types. It is used to the different interruption costs with load pattern of daily peak load. The objective functions such as power losses cost operation cost of DG, power buy cost and interruption cost are minimized for reliability improvement and efficient operation. The several indices for reliability evaluation are improved by dispersed generator installation. The proposed method is applied to IEEE 13 bus test systems to demonstrate its effectiveness.

A New Load Resonant Inverter Topology Considering Stray Inductance Influences for Induction Heating (부유 인덕턴스를 고려한 새로운 유도 가열용 부하 공진형 인버터)

  • Lee, Byung-Kuk;Yoo, Sang-Bong;Suh, Bum-Seok;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.416-419
    • /
    • 1995
  • An analysis of a new load resonant inverter considering stray inductance is given. There are several different types for load resonant inverters. They can offer zero turn-on as well as zero turn-off switching losses, yielding high efficiency at high power and high frequencies. However, they didn't consider the influences of stray inductance. In conventional topology using lossless snubber capacitor, stray inductances result in very high frequency resonant current. Especially, these influences can be problematic in high power system such as induction heating system with large current of some 10A associated with it. These currents increase EMI problem, give harmful effects in gate driver's operation and increase loss of dc-link capacitor as well as snubber capacitor. Therefore, the effect of stray inductances should be treated and reduced. This paper presents a new load resonant inverter topology, which can reduce the effect of stray inductances.

  • PDF

Square CFST columns under cyclic load and acid rain attack: Experiments

  • Yuan, Fang;Chen, Mengcheng;Huang, Hong
    • Steel and Composite Structures
    • /
    • v.30 no.2
    • /
    • pp.171-183
    • /
    • 2019
  • As China's infrastructure continues to grow, concrete filled steel tubular (CFST) structures are attracting increasing interest for use in engineering applications in earthquake prone regions owing to their high section modulus, high strength, and good seismic performance. However, in a corrosive environment, the seismic resistance of the CFST columns may be affected to a certain extent. This study attempts to investigate the mechanical behaviours of square CFST members under both a cyclic load and an acid rain attack. First, the tensile mechanical properties of steel plates with various corrosion rates were tested. Second, a total of 12 columns with different corrosion rates were subjected to a reversed cyclic load and tested. Third, comparisons between the test results and the predicted ultimate strength by using four existing codes were carried out. It was found that the corrosion leads to an evident decrease in yield strength, elastic modulus, and tensile strain capacity of steel plates, and also to a noticeable deterioration in the ultimate strength, ductility, and energy dissipation of the CFST members. A larger axial force ratio leads to a more significant resulting deterioration of the seismic behaviour of the columns. In addition, the losses of both thickness and yield strength of an outer steel tube caused by corrosion should be taken into account when predicting the ultimate strength of corroded CFST columns.

Sensitivity analysis of time-dependent behaviors of PSC flexural members (프리스트레스트 훰 부재의 시간 종속적 거동에 관한 민감도 해석)

  • 김민주;김동기;김택중;이용학
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.119-124
    • /
    • 2001
  • A general procedure to implement the sensitivity analysis of PSC flexural members is proposed based on the analytical calculation of the gradients of stresses and strains with respect to the 21 design variables in a closed format. The formulation covers the long term losses including concrete creep, shrinkage, and PS steel relaxation as well as load effects. The derived formulation is applied to the rectangular section PSC beam with prestressing and nonprestressing steels for the sensitivity analysis. The analytically calculated sensitivity results are compared with those numerically calculated.

  • PDF

Optimal Operation of Dispersed Generation in MicroGrid Systems (마이크로 그리드에서 분산전원의 최적 운영 방안)

  • Kim, Kyu-Ho;Rhee, Sang-Bong;Kim, Soo-Nam;Lee, Sang-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.486_487
    • /
    • 2009
  • This paper presents a method for optimal operation to improve reliability of MicroGrid systems considering load types and interruption cost. The objective functions such as power losses cost, operation cost of dispersed generations, power purchasing cost, and interruption cost are minimized for reliability improvement and efficient operation. The several indices for reliability evaluation are improved by renewable energy sources installation.

  • PDF

Optimal Var Allocation in system planning by stochastic Linear Programming (확률 선형 계획법에 의한 최적 Var 배분 계획에 관한 연구)

  • Song, Kil-Yeong;Lee, Hee-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.863-865
    • /
    • 1988
  • This paper presents a optimal Var allocation algorithm for minimizing transmission line losses and improving voltage profile in a given system. In this paper, nodal input data is considered as Gaussian distribution with their mean value and their variance. A Stocastic Linear programming technique based on chance constrained method is applied, to solve the var allocation problem with probabilistic constraint. The test result in 6-Bus Model system showes that the voltage distribution of load buses is improved and the power loss is more reduced than before var allocation.

  • PDF

Study on the Calculation of the Optimal Power Operation Considering Line Contingencies (상정사고를 고려한 전력계통 최적운용에 관한 연구)

  • 박영문;백영식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.241-246
    • /
    • 1984
  • The power system scheduling process is formulated as an optimization problem with linear inequality constraints. AC Loadflow method is used for the problem solution and line losses are considered. The constraints under consiceration are generator power limits, load schedding limits and line capacity limits. In solving the objective function the Dual Relaxation method is adopted. Tests indicate that the method is practical for real time applications.

  • PDF