• 제목/요약/키워드: Load Frequency Control

검색결과 790건 처리시간 0.026초

Design of HUST-PTF beamline control system for fast energy changing

  • Li, Peilun;Li, Dong;Qin, Bin;Zhou, Chong;Han, Wenjie;Liao, Yicheng;Chen, Aote
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2852-2858
    • /
    • 2022
  • A proton therapy facility is under development at Huazhong University of Science and Technology (HUST). To meet the need for fast energy changes during treatments, a beamline control system (BCS) has been designed and implemented. The BCS coordinates and controls various beamline devices by adopting a distributed architecture divided into three layers: the client, server, and device layers. Among these, the design of the server layer is the key to realize fast energy changes. The server layer adopts the submodule programming paradigm and optimizes the data interface among modules, allowing the main workflow to be separated from the device workflow and data. Furthermore, this layer uses asynchronous, multithreaded, and thread-locking methods to improve the system's ability to operation efficiently and securely. Notably, to evaluate the changing energy status over time, a dynamic node update method is adopted, which can dynamically adjust the update frequency of variable nodes. This method not only meets the demand for fast updates on energy changes but also reduces the server's communication load in the steady state. This method is tested on a virtual platform, and the results are as expected.

수용가 형태에 따른 전지전력저장시스템의 경제성 평가 (Economic Assessment of the Battery Energy Storage System with Its Customer Type)

  • 손학식;최준호;김재철
    • 조명전기설비학회논문지
    • /
    • 제16권2호
    • /
    • pp.81-89
    • /
    • 2002
  • 전지전력저장시스템은 부하 평준화, 순동 예비력 확보, 주파수·전압 조정, 신뢰도 향상 및 송변전 설비의 투자지연효과 등의 많은 장점을 가진다. 전지전력저장시스템의 보급을 확산하기 위해서는 수용가 입장에서 본 경제성 평가가 중요하다. 본 논문에서는 기존의 모델을 보완, 개선한 전지전력저장시스템의 경제성 평가 모델을 제안하였다. 제안된 경제성 평가 모델을 한국전력의 부하 조사로부터 얻어진 전형적 수용가인 경공업, 상업, 가정용 수용가에 적용하여 순현재가치, 수익률 등의 경제 척도를 통해 각 수용가의 경제성 타당성을 분석하였다. 이의 결과를 보면 전지전력저장시스템은 특정 수용가 형태(가정 수용가)에 유리하다는 것을 알 수 있었으며, 정부 및 에너지 에이전트는 이의 보급 확산을 위해 세금 혜택, 금융 지원 등의 프로그램을 실행하여야 할 것이다. 본 논문의 결과는 수용가의 투자 의사결정 및 정부 에너지 관련 부서의 정책에 도움이 될 것이다.

면내 압축 및 전단하중을 받는 적층 복합 보강 판의 자유진동해석 (Free Vibration Analysis of Laminated Composite Stiffened Plates under the In-plane Compression and Shear Loads)

  • 한성천;최삼열
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.191-203
    • /
    • 2006
  • 가정 변형률 9절점 쉘 요소를 이용하여 스티프너로 보강된 적층 복합 보강판의 진동 특성을 연구하였다. 기존의 연구결과들과 비교하기 위하여 대칭으로 적층된 carbon-epoxy 복합재료 적층 판을 사용하였다. 또한 본 연구에서 스티프너를 쉘로 모델링 한 결과들은 보 요소로 모델링 된 결과들과 비교하였다. 비틀림에 약한 스티프너의 경우에 국부 좌굴이 스티프너에서 발생할 수 있다. 이 경우에 스티프너는 쉘로 모델링 하여야 한다. 본 연구는 면내 압축 및 전단하중을 받는 적층 복합 보강 판과 보강되지 않은 적층 복합 판의 연구에 집중되어 있다. 면내 압축 및 전단하중은 적층복합 판의 고유진동수와 진동 모우드를 변화시키고 압축 하중의 증가는 압축 하중이 임계 좌굴하중에 도달하여 진동수가 0 이 될 때 까지 진동수를 감소시킨다. 면내 전단하중의 작용은 그렇지 않은 경우에 비하여 진동수를 증가시켰다. 또한 진동수와 면내 하중 관계 곡선의 교차는 적층 복합 보강판의 진동 모우드를 교체 시킨다. 본 연구에서 제시한 쉘 요소로 적층 복합 보강판을 해석한 결과 참고문헌과 비교하여 매우 정확한 결과를 나타내었다. 그러므로 보강된 적층 복합 판의 면내 전단 및 압축하중의 종류와 크기는 특정한 진동수와 모우드 형상의 조절을 위해 적절하게 선택되어야 한다. 고유치 문제를 풀기 위하여 Lanzcos 방법을 사용하였다.

에너지회생스너버를 적용한 하이브리드 3레벨 DC/DC 컨버터 (Hybrid Three-Level DC/DC Converter using an Energy Recovery Snubber)

  • 허예창;주종성;말론;김은수;강철하;이승민
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.36-43
    • /
    • 2017
  • This paper describes a hybrid multi-output three-level DC/DC converter suitable for a wide, high-input voltage range of an auxiliary power supply for a high-power photovoltaic generating system. In a high-power photovoltaic generating system, the solar panel output voltage depends on solar radiation quantity and varies from 450Vdc to 1100Vdc. The proposed hybrid multi-output three-level DC/DC converter, which is an auxiliary power supply, would be used as power source for control printed circuit boards and relay and cooling fans in a high-power photovoltaic generating system. The proposed multi-output ($24V_{DC}/30A$, $230V_{DC}/5A$) hybrid three-level boost converter, which uses an energy recovery snubber, is controlled by variable-frequency and phase-shifted modulations and can achieve zero-voltage switching with all operating conditions of input voltage and load range. Experimental results of a 2kW prototype are evaluated and implemented to verify the performance of the proposed converter.

새로운 능동 클램핑방식을 이용한 연료전지용 DC-AC 인버터의 특성 (Characteristic of fuel Cell DC-AC Inverter Using New Active Clamping Method)

  • 김칠용;조만철;문상필;김영준;김홍삼
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.337-340
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V], In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch S5 and S6 in the secondary switch, which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household.

  • PDF

하부요로계 폐색 진단용 요류음 계측 시스템의 구현 및 평가 (Implementation and estimation of the urophonography measurement system for diagnosis of Lower urinary tract symptom)

  • 정도운;조성택;전계록
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.7-15
    • /
    • 2005
  • A sensor and measuring system were implemented to measure both uroflow and urophonography signal during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the developed system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter which can most effectively reflected by the occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253{\sim}282$ Hz of the urophonography signal.

Vibration from a Shaft-Bearing-Plate System Due to an Axial Excitation of Helical Gears

  • Park, Chan-Il
    • Journal of Mechanical Science and Technology
    • /
    • 제20권12호
    • /
    • pp.2105-2114
    • /
    • 2006
  • In this paper, a simplified model is studied to predict analytically the vibration from the helical gear system due to an axial excitation of helical gears. The simplified model describes gear, shaft, bearing, and housing. In order to obtain the axial force of helical gears, the mesh stiffness is calculated in the load deflection relation. The axial force is obtained from the solution of the equation of motion, using the mesh stiffness. It is used as a longitudinal excitation of the shaft, which in turn drives the gear housing through the bearing. In this study, the shaft is modeled as a rod, while the bearing is modeled as a parallel spring and damper only supporting longitudinal forces. The gear housing is modeled as a clamped circular plate with viscous damping. For the modeling of this system, transfer matrices for the rod and bearing are used, using a spectral method with four pole parameters. The model is validated by finite element analysis. Using the model, parameter studies are carried out. As a result, the linearized dynamic shaft force due to the gear excitation in the frequency domain was proposed. Out-of-plan displacement from the forced vibrating circular plate and the renewed mode normalization constant of the circular plate were also proposed. In order to control the axial vibration of the helical gear system, the plate was more important than the shaft and the bearing. Finally, the effect of the dominant design parameters for the gear system can be investigated by this model.

2차 델타 시그마 변조기법을 이용한 고 정밀 및 고 안정 디지털 전자석 전원 장치에 관한 연구 (A Study on High Precision and High Stability Digital Magnet Power Supply Using Second Order Delta-Sigma modulation)

  • 김금수;장길진;김동희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.69-80
    • /
    • 2015
  • This paper is writing about developing magnet power supply. It is very important for power supply to obtain output current in high precision and high stability. As a switching noise and a power noise are the cause of disrupting the stability of output current, to remove these at the front end, low pass filter with 300Hz cutoff frequency is designed and placed. And also to minimize switching noise of the current into magnet and to stop abrupt fluctuations, output filter should be designed, when doing this, we design it by considering load has high value inductance. As power supply demands the stability of less than 5ppm, high precision 24bit(300nV/bit) analog digital converter is needed. As resolving power of 24bit(300nV/bit) analog digital converter is high, it is also very important to design the input stage of analog digital converter. To remove input noise, 4th order low pass filter is composed. Due to the limitation of clock, to minimize quantization error between 15bit DPWM and output of ADC having 24bit resolving power, ${\Sigma}-{\Delta}$ modulation is used and bit contracted DPWM is constituted. And before implementing, to maximize efficiency, simulink is used.

구리박막의 피로특성에 관한 제조공정의 영향 (Manufacturing Process Effect on Fatigue Properties for Copper Thin Film)

  • 안중혁;박준협;김윤재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1783-1786
    • /
    • 2007
  • The copper film coated by Sn is often used in various applications such as LCD, Mobile Phone and etc. Especially, when the film is used as tape carrier package(TCP) of LCD panel, the film is repeatedly applied by mechanical or(and) thermal stress and then is often failed. Therefore, to guarantee the reliability of the electrical devices using the film, the tensile and fatigue characteristics of the film are important. In this study, to obtain the tensile and fatigue characteristics of the film, the specimen was fabricated by etching process to make a smooth specimen of 2000 ${\mu}m$ width, 8000 ${\mu}m$ length and 15.26 ${\mu}m$ thickness. The 2 kinds of specimen were fabricated by other manufacturing process. These specimens had values of Young's modulus(80.2GPa) lower than literature values(108${\sim}$145GPa) for bulk values, but had high values of the yield and ultimate strength as 317MPa and 437MPa, respectively. And fatigue test of load-control with 20Hz frequency was performed.

  • PDF

거주자의 거동으로 발생하는 바닥진동의 층간 전달 및 바닥충격음의 음압레벨 특성 평가 (Characteristics of Transmission of Floor Vibration and Floor Impact Noise Due to Human Activities)

  • 이민정;최현기
    • 한국소음진동공학회논문집
    • /
    • 제27권1호
    • /
    • pp.5-13
    • /
    • 2017
  • Noise complaints among neighbors in apartment building are mainly caused by floor impact noise that is structure born noise due to occupant induced floor vibration. To control this noise problems many researchers have investigated floor systems and finishing materials. Light-weight impact noise affects by finishing materials, but heavy-weight impact noise induced by heel impacts during normal walking or jumping of children is concerned with structural system and floor vibration. To figure out the characteristics of floor impact noise and transmission of floor vibration due to human activities, vibration tests were conducted in apartment buildings. Impact hammer, heel drop and walking activities were loaded at center of upstairs living room, and accelerations of slabs for both upstairs and downstairs and sound pressure levels for downstairs were measured. The acceleration ratio of transmitted floor vibration to downstairs and human induced vibration in upstairs was between 0.5 and 1.0 according to slab size, wall, and load type. And floor impact noise occurred in the range of natural frequency of slab.