• 제목/요약/키워드: Load Frequency Control

검색결과 790건 처리시간 0.026초

A New Control Scheme for a Class-D Inverter with Induction Heating Jar Application by Constant Switching Frequency

  • Choi Won-Suk;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Journal of Power Electronics
    • /
    • 제5권4호
    • /
    • pp.272-281
    • /
    • 2005
  • In this paper, a simple power control scheme for a constant frequency Class-D inverter with a variable duty cycle is proposed. It is more suitable and acceptable for high- frequency induction heating (IH) jar applications. The proposed control scheme has the advantages of not only wide power regulation range but also ease of control output power. Also it can achieve a stable and efficient Zero-Voltage-Switching (ZVS) in a whole load range. The control principles of the proposed method are described in detail and its validity is verified through simulated and experimental results on 42.8kHz IGBT for induction heating rated on 1.6kW with constant frequency variable power.

주파수변화율을 이용한 제주계통 부하차단 방안 (A Scheme for the Load Shedding on Cheju Power Systems using Rate of Change of Frequency)

  • 장병태;이소영;조경보;곽노홍;안정식;오화진;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.184-186
    • /
    • 2003
  • Power systems must be operated within limits that will ensure adequate generation and transmission capacity to avoid cascading. In developing a set of operations limits, it is important to do so within a general framework in order to ensure that the operating objectives are met. In the this regard, when the system experiences a generation-load imbalance, the principles of sound operation will be maintained by bringing under control an unscheduled power flow condition as quickly as possible. This paper presents load shedding application which responds both to frequency and to rate of change of frequency. Its application is in the operating situation of load suddenly in excess of generation, either because of generator or other equipment failure. A scheme which is able to utilize rate of change of frequency as well as frequency itself is an improvement over existing scheme.

  • PDF

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

제주-해남 HVDC 시스템의 주파수 검출방식 변경에 관한 연구 (A Study on the Modification of Frequency Detection Methode for Cheju-Heanam HVDC System)

  • 박종광;김찬기;양병모
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.176-178
    • /
    • 2005
  • In this paper deals with the frequency control of the HVDC scheme linking Haenam to Cheju Island. The primary aim of the study is to develop and evaluate a new frequency control that can be employed without having to utilize the existing Synchronous Compensators(Gas Turbines). Study cases are completed involving synchronous compensators trip and load tripping events and study plots presented. It is demonstrated that the existing frequency measurement can be replaced by one derived from the AC network alone, incorporated into a new frequency control algorithm and gives good frequency control and dynamic performance.

  • PDF

직류 마이크로그리드에서 펄스형 부하 보상용 슈퍼커패시터 무순단 제어법 (A Seamless Control Method for Supercapacitor to Compensate Pulsed Load in DC Microgrid)

  • 담두이헝;이홍희
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.265-272
    • /
    • 2018
  • This paper proposes a new control method for the supercapacitor (SC) to compensate the pulsed load and to enhance the power quality of the DC microgrid. By coordinating the operating frequency, the SC is controlled to handle the surge current, while the low-frequency current component is dealt with by the remaining sources in the system. The operation mode of the SC unit is automatically changed based on the state of charge and DC bus voltage level. Meanwhile, the mismatch in the power demand is covered by the SC unit by regulating the DC bus voltage level. The effectiveness of the proposed method is verified experimentally by the prototype with two distributed generators and one SC unit.

전력선 통신을 이용한 원격 부하제어 시스템의 구축 (Implementation of Control System for Remote Load using Power line Communication)

  • 김호;이원선;전희종;박종찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.685-688
    • /
    • 2002
  • This paper deals with new scheme of remote load control management system with communication from RCU to controller using power line Power line communication is useful for economical data link but various problems and limitations are caused in using power lines for communications channel. A power line is not so good in the commercial electrical power, and its load noise and high frequency noise are so much. To decrease these noise, we used the FSK(Frequency Shift Keying) modulation method. The experimental results show that the proposed system in this paper is compatible with the conventional system with low cost and the feasibility is very high for new or remodeling plant.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

PIR Speed Control Method of AC Motors Considering Time Delay in Speed Information

  • Lee, Jung-Ho;Choi, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2289-2297
    • /
    • 2017
  • Applying a periodic load torque to an AC motor generates a ripple, which is synchronized to the frequency of the periodic load torque, at the speed of the motor. Consequently, numerous studies have focused on reducing the speed ripple caused by the load torque. However, it is difficult to reduce the speed ripple when there is a time delay in acquiring speed information, such as that from a sensorless control. Therefore, we propose a speed control method for reducing speed ripples caused by a periodic load torque when there is a time delay in acquiring the speed information. The proposed method is verified by conducting simulations using the Simulink program from MATLAB, and by applying the method to an actual motor in which speed ripples occur due to a periodic load torque that is synchronized with the speed of the motor.

횡하중에 대한 점성 및 점탄성감쇠기의 진동제어성능의 비교 (Comparison of Motion Control Capacity of Viscous and Viscoelastic Dampers for Lateral Loads)

  • 김진구;김유경
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권2호
    • /
    • pp.155-162
    • /
    • 2001
  • In this study a structure with viscoelastic and viscous dampers with identical damping coefficient subjected to stationary seismic and wind load were analyzed in time and frequency-domain to compare motion control capability of viscous and viscoelastic dampers. The dampers were placed based on story drift and acceleration obtained from RMS responses. According to the analysis results, the motion control capability of viscous dampers turned out to be superior to that of the viscoelastic dampers for the case of seismic load. On the contrary, in case of wind load, the viscoelastic dampers were more effective in the mitigation of dynamic responses. However, it was also found that the differences were in a narrow margin.

  • PDF

정지형 UPS의 병렬운전 제어 (The Parallel Operation Control of Static UPSs)

  • 민병권;원충윤
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF