• 제목/요약/키워드: Load Cell Sensor

검색결과 124건 처리시간 0.031초

Development of Real-time Checking System on Ringer's Solution Using Load Cell

  • Ha, Kwan-Yong;Nam, Chul;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1409-1412
    • /
    • 2005
  • Therefore this study focused on developing real-time system, which makes it possible for nurses to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution. This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by A/D converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

중량선과기(重量選果機)의 중량감지부(重量感知部) 개선(改善)에 관(關)한 연구(硏究) (Development of Weight Sensing Unit of Fruit Weight Grader Using Load Cell)

  • 김효수;고학균
    • Journal of Biosystems Engineering
    • /
    • 제18권4호
    • /
    • pp.358-370
    • /
    • 1993
  • In Korea, fruit grading has been mainly done manually, and manual grading depends on human sense. Thus it is subjected to human error and is not always as consistent as would be desired. Therefore, a study on the development of fruit grader was initiated to improve the consistency of fruit grading. The sensitivity for fruit weight of the conventional spring type weight grader has a tendency to decrease by physical characteristics of spring which is used as a weight sensing unit. This study was carried out to develop weight measuring device for establishing the base of weight sensing unit of electronic weight grader. This device consists of a weight sensor using load cell, data acquisition system, and a microcomputer containing program to calculate fruit weight. The weight measuring device using load cell was developed to increase sensitivity of fruit weight. The result of this study showed that the weight sensing unit of electronic weight grader contributed to the improvement of performance of weight measuring device.

  • PDF

로드셀과 자이로센서를 융합한 수액 감지 시스템 설계 및 오차 검증 (Design and Error Verification of Intravenous Injection Detection System that Combines Load Cell and Gyro Sensor)

  • 김선칠
    • 한국융합학회논문지
    • /
    • 제12권1호
    • /
    • pp.127-132
    • /
    • 2021
  • 의료기관에서 사용되는 수액 모니터링 시스템은 원격으로 환자에게 투입된 수액량과 투여의 종료시점 정보를 제공하기 위해서 개발되었다. 수액 투입량을 측정하기 위해서는 수액 내부에서 외부로 나가는 정량을 무게로 혹은 유량을 측정센서로 측정할 수 있다. 여기에 적용되는 장치의 기준은 정확성, 경계성이다. 또한 소형으로 환자에게 수액 설치시 사용에 용이해야 한다. 의료기관에서는 측정값의 정확도가 높아야 하며, 경제적으로 저가의 장치를 요구하고 있다. 본 연구에서는 저가의 소형 무게 중심 로드셀 센서를 적용하였으며, 측정값의 정확도를 위해 자이로센서와 융합하여 외부 움직임에 의한 아트펙트를 줄이는 알고리즘을 적용하였다. 그 결과 측정의 오차를 줄일 수 있어 수액 모니터링 측정값의 정확도를 향상시키는 효과를 확인하였다.

병렬판구조를 이용한 소형 6축 힘/토크센서의 설계 및 특성평가 (Design and evaluation of small size six-axis force/torque sensor using parallel plate sturcture)

  • 주진원;나기수;김갑순
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.353-364
    • /
    • 1998
  • This paper describes the design processes and evaluation results of a small-sized six-axis force/torque sensor. The new six-axis force/torque sensor including S-type structure has been developed using a parallel plate structure as a basic sensing element. In order tominimize coupling errors, the location of strain gages has been determined based on the finite element analysis and the connections of strain gages have been made such that the bridge circuit with 4 strain gages becomes balanced. Several design modifications result in a similar strain sensitivity for six-axis forces and moments, and the reduced coupling errors of 2.6% FS between each forces and moments. Calibration test results show that the six-axis load cell developed which has light weight of 135g and the maximum capacities of 196 N in forces and 19.6 N.m in moments is estimated to be within 7.1% FS in coupling error.

최적조건 선정을 위한 Pad 특성과 Wafer Final Polishing의 가공표면에 관한 연구 (The Study on the Wafer Surface and Pad Characteristic for Optimal Condition in Wafer Final Polishing)

  • 원종구;이은상;이상균
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.26-32
    • /
    • 2012
  • Polishing is one of the important methods in manufacturing of Si wafers and in thinning of completed device wafers. This study will report the characteristic of wafer according to processing time, machining speed and pressure which have major influence on the abrasion of Si wafer polishing. It is possible to evaluation of wafer abrasion by load cell and infrared temperature sensor. The characteristic of wafer surface according to processing condition is selected to use a result data that measure a pressure, machining speed, and the processing time. This result is appeared by the characteristic of wafer surface in machining condition. Through that, the study cans evaluation a wafer characteristic in variable machining condition. It is important to obtain optimal condition. Thus the optimum condition selection of ultra precision Si wafer polishing using load cell and infrared temperature sensor. To evaluate each machining factor, use a data through each sensor. That evaluation of abrasion according to variety condition is selected to use a result data that measure a pressure, machining speed, and the processing time. And optimum condition is selected by this result.

저장공간에 채워진 부피 모니터링 시스템 개발 (Development of Volume Monitoring System Filled in Storage Space)

  • 이영태;권익현
    • 반도체디스플레이기술학회지
    • /
    • 제18권4호
    • /
    • pp.129-133
    • /
    • 2019
  • In this paper, we developed a system to monitor the storage capacity of suction-type device such as vacuum cleaner or crop harvesters. The monitoring system consists of load cells and a differential pressure sensor which simultaneously monitor the weight and volume of the stock. Since weighing objects stored in storage containers alone cannot fully monitor the level of filling, more accurate monitoring can be achieved by monitoring volume and fusion with weight information. The volume was monitored using a phenomenon in which the flow rate of the inhaled air varies depending on the volume of the object filled in the storage container. In this paper, we developed a system to monitor the storage in three stages: low, medium and high.

압력센서를 이용한 세그웨이 개발 (Implementation of Segway Using Pressure Sensors)

  • 조성찬;강수민;허경무;주영복
    • 전자공학회논문지
    • /
    • 제50권1호
    • /
    • pp.285-290
    • /
    • 2013
  • 최근 현대사회는 고도의 발전과 더불어 화석연료 사용으로 인한 환경문제가 대두되고 있다. 그래서 저공해 에너지 및 기술개발 등 지속적인 노력을 기울이고 있지만 기존의 화석연료와 자동차를 대체 할 수 있을 만한 수준의 성과를 거두지는 못하고 있다. 따라서 본 연구에서는 21세기 전기 오토모바일 분야에서 세그웨이(Segway) 기술을 토대로 단점을 보안하고 새로운 인터페이스의 방향을 제시하는데 그 목적을 두고 있다. 세그웨이는 자체의 기울어짐을 이용해서 제어를 하기 때문에 어느정도 경사가 있는 곳에서 기울기를 잘못 조절하면 그대로 넘어지는 문제가 있다. 본 연구는 이러한 단점을 해결해 보고자 2개의 압력센서(Load cell)를 사용하여 체중비율에 따른 제어방법을 도입해 보았다. 또, 경사로에서의 수월한 운행을 위해서 자이로센서와 가속도 센서를 사용해서 값을 보정해 경사에서도 자유로운 제어방법을 연구해 보았다. 탑승자의 체중과 경사각에 따른 압력센서의 압력 감지값을 실험으로 측정하여 산출해 본 결과 경사각에 비해서 체중에 대한 제어변수 변화량이 크다는 점을 알 수 있다. 결과적으로 압력센서를 사용해서 만든 세그웨이또한 제어가 간편하며 경사로 등에서의 안정성도 높은 것을 알 수 있다.

정전용량 수분센서의 배지 함수량 정량화 (Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor)

  • 백정현;박주성;이호진;안진희;최은영
    • 생물환경조절학회지
    • /
    • 제30권1호
    • /
    • pp.27-36
    • /
    • 2021
  • 정전용량 수분측정 센서는 수경용 배지 양쪽에 구리 및 테플론으로 절연된 전극판(30cm×10cm)을 부착하여 배지의 넓은 부분에 걸쳐 측정하도록 개발되었다. 본 연구는 콘덴서형 정전용량 센서로부터 출력되는 정전용량 값을 배지 함수량으로 변환하는 것이다. 정량화 실험은 양액을 공급하면서 배지 물무게와 정전용량 변화를 측정하고 그 값을 비교하는 방식으로 수행되었다. 배지 함수량과 정전용량은 본 연구를 위해 특별히 개발된 소프트웨어와 함께 센서와 로드셀을 사용하여 20~30초마다 측정되었다. 상용 curve-fitting 프로그램을 이용하여 배지 함수량과 정전용량을 변수로 정전용량 값으로 배지 함수량을 추정하였다. 공급하는 물의 양이 증가하면 정전용량도 증가하는 경향을 보였다. 배지 내 물무게에 따른 정전용량에 대한 변동계수(coefficient of variation, cv)는 배지 내 물무게가 1.0kg 수준에서 다른 무게에 비해 높아 함수량 보정은 물무게를 1.7~6.0kg 수준에서 수행하였다. 정전용량과 물무게 사이의 상관 계수는 0.996이었고 보정식에 의해 정전용량으로 추정된 함수량은 로드셀로 측정한 배지 함수량과 비교하였다.

원격 수액모니터링 시스템의 주입량의 정확도에 영향을 주는 융합인자의 비교 분석 (Comparative analysis of fusion factors affecting the accuracy of injection amount of remote fluid monitoring system)

  • 김선칠
    • 한국융합학회논문지
    • /
    • 제13권3호
    • /
    • pp.125-131
    • /
    • 2022
  • 최근에는 COVID-19 인해 의료기관에서 원격으로 관리되는 환자케어 시스템의 보급이 증가되고 있다. 특히 수액 모니터링인 경우 환자의 안전과 간호사의 업무를 줄일 수 있는 시스템으로 병원에서 도입을 고려하고 있다. 현재 개발되어 있는 제품은 무게를 측정하는 로드셀 방식과 적외선 센싱으로 수액 방울을 검출하는 방식의 두 가지 제품이 있다. 각 제품은 동작원리, 센서의 종류, 크기, 사용법, 가격등의 차이가 있지만, 의료기관에서는 획득되는 데이터의 정확도에 관심이 높다. 본 연구에서는 센서 방식이 다른 두 가지 시제품을 제작하여 수액모니터링 장치의 핵심인 정확도를 실험하기 위해 시간당 총 수액량을 측정하였다. 또 외부의 움직임이 있을 경우 수액 측정값의 변화를 실험하여 측정방식에 따른 정확도를 평가하였다. 실험 결과 두 장치의 측정값 오차는 5% 미만의 차이가 있었고, 로드셀 방식은 저용량 측정값에서 적외선 방식은 고용량 측정값에서 차이를 보였다. 본 연구결과 수액모니터링장치의 센서방식에 따른 정확도 차이는 거의 없었고, 향후 의료기관에서 사용할 경우 정확도의 문제는 없을 것으로 사료된다.