Development of Real-time Checking System on Ringer's Solution Using Load Cell

  • Ha, Kwan-Yong;Nam, Chul;;Kim, Hie-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1409-1412
    • /
    • 2005
  • Therefore this study focused on developing real-time system, which makes it possible for nurses to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution. This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by A/D converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

Development of Weight Sensing Unit of Fruit Weight Grader Using Load Cell (중량선과기(重量選果機)의 중량감지부(重量感知部) 개선(改善)에 관(關)한 연구(硏究))

  • Kim, H.S.;Koh, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.4
    • /
    • pp.358-370
    • /
    • 1993
  • In Korea, fruit grading has been mainly done manually, and manual grading depends on human sense. Thus it is subjected to human error and is not always as consistent as would be desired. Therefore, a study on the development of fruit grader was initiated to improve the consistency of fruit grading. The sensitivity for fruit weight of the conventional spring type weight grader has a tendency to decrease by physical characteristics of spring which is used as a weight sensing unit. This study was carried out to develop weight measuring device for establishing the base of weight sensing unit of electronic weight grader. This device consists of a weight sensor using load cell, data acquisition system, and a microcomputer containing program to calculate fruit weight. The weight measuring device using load cell was developed to increase sensitivity of fruit weight. The result of this study showed that the weight sensing unit of electronic weight grader contributed to the improvement of performance of weight measuring device.

  • PDF

Design and Error Verification of Intravenous Injection Detection System that Combines Load Cell and Gyro Sensor (로드셀과 자이로센서를 융합한 수액 감지 시스템 설계 및 오차 검증)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.127-132
    • /
    • 2021
  • The intravenous injection monitoring system used by medical institutions was developed to remotely provide patients with the amount of intravenous injected and the termination point of the injection. In order to measure the amount of intravenous injection input, the weight or flow rate of the level going out from the inside to outside of the intravenous injection can be observed with a measuring sensor. The criteria for devices that apply herein are accuracy and vigilance. In addition, it is compact and should be easy to use when installing intravenous injection on patients. In medical institutions, the accuracy of the measured values must be high, and economically inexpensive devices are required. In this study, low-cost small-weight-centered load cell sensors were applied, and algorithms were applied to reduce the artefact by external movement by converging with gyro sensors for accuracy of measurements. As a result, it was possible to reduce the error of measurement, thereby improving the accuracy of the intravenous injection monitoring measurement value.

Design and evaluation of small size six-axis force/torque sensor using parallel plate sturcture (병렬판구조를 이용한 소형 6축 힘/토크센서의 설계 및 특성평가)

  • Joo, Jin-Won;Na, Gi-Su;Kim, Gap-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.353-364
    • /
    • 1998
  • This paper describes the design processes and evaluation results of a small-sized six-axis force/torque sensor. The new six-axis force/torque sensor including S-type structure has been developed using a parallel plate structure as a basic sensing element. In order tominimize coupling errors, the location of strain gages has been determined based on the finite element analysis and the connections of strain gages have been made such that the bridge circuit with 4 strain gages becomes balanced. Several design modifications result in a similar strain sensitivity for six-axis forces and moments, and the reduced coupling errors of 2.6% FS between each forces and moments. Calibration test results show that the six-axis load cell developed which has light weight of 135g and the maximum capacities of 196 N in forces and 19.6 N.m in moments is estimated to be within 7.1% FS in coupling error.

The Study on the Wafer Surface and Pad Characteristic for Optimal Condition in Wafer Final Polishing (최적조건 선정을 위한 Pad 특성과 Wafer Final Polishing의 가공표면에 관한 연구)

  • Won, Jong-Koo;Lee, Eun-Sang;Lee, Sang-Gyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • Polishing is one of the important methods in manufacturing of Si wafers and in thinning of completed device wafers. This study will report the characteristic of wafer according to processing time, machining speed and pressure which have major influence on the abrasion of Si wafer polishing. It is possible to evaluation of wafer abrasion by load cell and infrared temperature sensor. The characteristic of wafer surface according to processing condition is selected to use a result data that measure a pressure, machining speed, and the processing time. This result is appeared by the characteristic of wafer surface in machining condition. Through that, the study cans evaluation a wafer characteristic in variable machining condition. It is important to obtain optimal condition. Thus the optimum condition selection of ultra precision Si wafer polishing using load cell and infrared temperature sensor. To evaluate each machining factor, use a data through each sensor. That evaluation of abrasion according to variety condition is selected to use a result data that measure a pressure, machining speed, and the processing time. And optimum condition is selected by this result.

Development of Volume Monitoring System Filled in Storage Space (저장공간에 채워진 부피 모니터링 시스템 개발)

  • Lee, Young Tae;Kwon, Ik Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.129-133
    • /
    • 2019
  • In this paper, we developed a system to monitor the storage capacity of suction-type device such as vacuum cleaner or crop harvesters. The monitoring system consists of load cells and a differential pressure sensor which simultaneously monitor the weight and volume of the stock. Since weighing objects stored in storage containers alone cannot fully monitor the level of filling, more accurate monitoring can be achieved by monitoring volume and fusion with weight information. The volume was monitored using a phenomenon in which the flow rate of the inhaled air varies depending on the volume of the object filled in the storage container. In this paper, we developed a system to monitor the storage in three stages: low, medium and high.

Implementation of Segway Using Pressure Sensors (압력센서를 이용한 세그웨이 개발)

  • Jo, Sung-Chan;Kang, Su-Min;Huh, Kyung-Moo;Joo, Young-Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.285-290
    • /
    • 2013
  • As well as the advanced development of modern society, and the environmental problems caused by the use of fossil fuels is emerging. So do not reap the performance level of the car to be able to replace existing fossil fuel and low-emission energy and technology development are continually strives. Therefore, this study aims to present the direction of the new interface 21st century Mobile Auto Electric Segway technology in the field of security and disadvantages based. The Segway is a problem because the control itself skewed by certain slope where the slope in the wrong adjustment tipping. In this study, the year saw the introduction of two pressure sensors(Load cell) used to solve these drawbacks, according to the ratio of the weight control methods. In addition, the ramps operate in a straightforward, using an acceleration sensor and a gyro sensor in order to compensate for the slope value in free control method to study looked. Measured by calculating the value of the occupant's weight and according to the inclination of the pressure sensor pressure sensing experiment results this year, we can see that the control variable for the change in body weight is greater than the inclination. Segway is also easy to control, and the stability of the ramps, etc. As a result, created using a pressure sensor.

Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor (정전용량 수분센서의 배지 함수량 정량화)

  • Baek, Jeong-Hyeon;Park, Ju-Sung;Lee, Ho-Jin;An, Jin-Hee;Choi, Eun-Young
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.27-36
    • /
    • 2021
  • A capacitive water sensor was developed to measure the capacitance over a wide part of a substrate using an insulated electrode plate (30 cm × 10 cm) with copper and Teflon attached on either side of the substrate. This study aimed to convert the capacitance output obtained from the condenser-type capacitance sensor into the substrate water content. The quantification experiment was performed by measuring the changes in substrate water weight and capacitance while providing a nutrient solution and by subsequently comparing these values. The substrate water weight and capacitance were measured every 20 to 30 seconds using the sensor and load cell with a software developed specifically for this study. Using a curve-fitting program, the substrate water content was estimated from the output of the capacitance using the water weight and capacitance of the substrate as variables. When the amount of water supplied was increased, the capacitance tended to increase. Coefficient of variation (CV) in capacitance according to the water weight in substrate was greater with the 1.0 kg of water weight, compared with other weights. Thus, the fitting was performed with higher than 1.0 kg, from 1.7 to 6.0 kg of water weight. The correlation coefficient between the capacitance and water weight in substrate was 0.9696. The calibration equation estimated water content from the capacitance, and it was compared with the substrate water weight measured by the load cell.

Comparative analysis of fusion factors affecting the accuracy of injection amount of remote fluid monitoring system (원격 수액모니터링 시스템의 주입량의 정확도에 영향을 주는 융합인자의 비교 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.125-131
    • /
    • 2022
  • Recently, the prevalence of remotely managed patient care systems in medical institutions is increasing due to COVID-19. In particular, in the case of fluid monitoring, hospitals are considering introducing it as a system that can reduce patient safety and nurses' work. There are two products under development: a load cell method that measures weight and a method that detects drops of sap by infrared sensing. Although each product has differences in operation principle, sensor type, size, usage, and price, medical institutions are highly interested in the accuracy of the data obtained.In this study, two prototypes with different sensor methods were manufactured and the total amount of infusion per hour was measured to test the accuracy, which is the core of the infusion monitoring device. In addition, when there was an external movement, the change in the measured value of the sap was tested to evaluate the accuracy according to the measurement method. As a result of the experiment, there was a difference of less than 5% in the measurement value error of the two devices, and the load cell method showed a difference in the low-capacity measurement value and the infrared method in the high-capacity measurement value. As a result of this experiment, there was little difference in accuracy according to the sensor method of the infusion monitoring device, and it is considered that there is no problem in accuracy when used in a medical institution.