• Title/Summary/Keyword: Livestock buildings

Search Result 18, Processing Time 0.022 seconds

Development of New Conceptual Ventilation Graphs for Mechanically Ventilated Livestock Buildings (畜舍의 換氣量 決定을 위한 새로운 換氣그래프 開發)

  • Choi, Hong-Lim;Kim, Woo-Joong;Kim, Hyeon-Tae
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.3
    • /
    • pp.91-100
    • /
    • 1991
  • Since ventilation in livestock buildings is critical for indoor air quality, the first step in designing environmental control is to determine required ventilation rate. The purpose of the study was to suggest a conceptually new ventilation graph for determining minimum/maximum ventilation rate based on the conservation law of the thermal energy and mass in livestock buildings. PC-based programs coded with PASCAL language, [RVALUE] for overall thermal resistance of composite structural walls/ceilings, [POLYNOM] for coefficients values of animal's sensible heat equation were involved in developing a computer program, [VENTGRPH] for the determination of ventilation rate. It would be useful for design, for such a program would permit the designer to explore various design options and immediately, see the result in terms of its effect on minimum ventilation rates.

  • PDF

Analysis of the Wind Pressure Coefficient Characteristic of Livestock Shed Roof Surface according to the Opening of Side Walls (측벽 개방유무에 따른 축사지붕면의 풍압계수 특성분석)

  • You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • Livestock buildings are rural facilities as vulnerable to natural disasters as vinyl houses. Many of livestock buildings have a roof but without side walls. The roof of such structures is easily blown away by a typhoon and this results in a heavy loss. Therefore, farmers install winch curtains on the sides to prevent damages caused by typhoons. This study purposed to examine the distribution of wind pressure coefficient among different positions of livestock shed roof according to the opening of side walls. It was found that according to the distribution of peak external pressure coefficient on the roof surface of livestock shed, the wind blowing at wind angle $0^{\circ}$ was disadvantageous to roof surface regardless of the presence of side walls. However, it was confirmed that the peak external pressure coefficient was affected by wind angle and the length of eave depending on the presence of side walls.

A Study on Separation Distance between Industrial Source and Residential Areas to Avoid Odor Annoyance Using AUSPLUME Model (AUSPLUME 모델을 이용한 악취를 피하기 위한 산업오염원과 주거단지 사이 이격거리에 관한 연구)

  • 정상진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.5
    • /
    • pp.393-400
    • /
    • 2002
  • Separation distance between industrial source and residential areas to avoid odor annoyance was investigated using AUSPLUME model. A Gaussian plume model (AUSPLUME) for the dispersion was used to calculate odor emission from ground level area source. Using the dispersion model to calculate ambient odor concentrations, the separation distance between industrial source and residental areas was defined by %HA (percentage of highly annoyed person) and odor percentile concentration (C98). The result was compared with the separation distance of various nation guidelines for livestock buildings. The calculated separation distance for industrial source showed similar pattern comparing with various guidelines for livestock buildings.

A Field Survey on Concentration of Odor Compounds in Pig Buildings and Boundary Areas (돈사 내 및 부지경계에서 악취물질 발생 조사 연구)

  • Yoo Yong-Hee;Kim Tae-Il;Jeong Jong-Won;Gwak Jeong-Hun;Choi Hee-Chul;Song Jun-Ik;Yang Chang Bum;Jang Young-Kee;Kim Ho-Jung;Song Ki-Pong
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • A field survey was conducted to determine the concentration of odor compounds from pig buildings and that were 20 meters within the boundary area. The odor compounds were measured from large, medium and small farms with enclosed and open housing systems and slurry and sawdust manure fermentation treatment methods. Among the odor compounds investigated, ammonia ($NH_3$) had the highest concentration at 0.9 ${\~}$ 21.0 ppm followed by Hydrogen Sulfide($H_2S$) with a wide variation concentration of 51.9 ${\~}$ 6,712.4 pub, Uethylmercaptan($CH_3SH$) with non-detectable (N. D.) ${\~}$ 12.9 ppb, Dimethylsulphide($(CH_3)_2S$), with N. D. ${\~}$ 5.2 ppb and Dimethyldisulphide($(CH_3)_2S_2$) with N. D. ${\~}$ 2.6 ppb. Considering the prevailing wind direction and air velocity ranging from 0.23 to 0.73 m/s within the boundary area, the odorous matters; $NH_3$, $H_2S$, $CH_3SH$, $(CH_3)_2S_2$ and $(CH_3)_2S$ were 0.2${\~}$4.5 ppm, 0.01 ${\~}$0.06 ppb, N. D. ${\~}$0.009ppb, N. D.${\~}$0.002ppb and N. D. for $(CH_3)_2S$ respectively. These findings suggested that the Odor compounds $(CH_3)_2S_2$ had the lower detection in the boundary area whilst $(CH_3)_2S$ had no detection level within a 20-meter distance only. However, with these results odor compounds from pig buildings has to be further investigated under more controlled environmental factors.

  • PDF

Calculated external pressure coefficients on livestock buildings and comparison with Eurocode 1

  • Kateris, D.L.;Fragos, V.P.;Kotsopoulos, T.A.;Martzopoulou, A.G.;Moshou, D.
    • Wind and Structures
    • /
    • v.15 no.6
    • /
    • pp.481-494
    • /
    • 2012
  • The greenhouse type metal structures are increasingly used in modern construction of livestock farms because they are less laborious to construct and they provide a more favorable microclimate for the growth of animals compared to conventional livestock structures. A key stress factor for metal structures is the wind. The external pressure coefficient ($c_{pe}$) is used for the calculation of the wind effect on the structures. A high pressure coefficient value leads to an increase of the construction weight and subsequently to an increase in the construction cost. The EC1 in conjunction with EN 13031-1:2001, which is specialized for greenhouses, gives values for this coefficient. This value must satisfy two requirements: the safety of the structure and a reduced construction cost. In this paper, the Navier - Stokes and continuity equations are solved numerically with the finite element method (Galerkin Method) in order to simulate the two dimensional, incompressible, viscous air flow over the vaulted roofs of single span and twin-span with eaves livestock greenhouses' structures, with a height of 4.5 meters and with length of span of 9.6 and 14 m. The simulation was carried out in a wind tunnel. The numerical results of pressure coefficients, as well as, the distribution of them are presented and compared with data from Eurocodes for wind actions (EC1, EN 13031-1:2001). The results of the numerical experiment were close to the values given by the Eurocodes mainly on the leeward area of the roof while on the windward area a further segmentation is suggested.

Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea (국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사)

  • Jeong J. W.;Yoo Y. H.;Song J. I.;Kim T. I.;Jeon B. S.;Yang C. B.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2005
  • The farm house structure, ventilation system and manure treatment of two-storey buildings and sawdust pig houses were surveyed and analyzed. Based on the data for ten selected farms in five provinces during eight months, the goal is to eventually establish a standard two-storey pig house. Manure treatments were composting, slurry and activated sludge in two-storey pig houses, while fermentation method was done in sawdust pig house. The depth of sawdust as a litter material were 10 to 60cm, with a duration of 1/2, 1, 3 and 6 months, respectively. The ventilation systems were the mechanical type in two-storey pig houses and natural system in the sawdust pig house. Side wall in the two-storey pig house was enclosed with insulation materials such as block, colored metal sheet and sandwich panels. The minimum ceiling height in the first floor of the two-storey pig house was 2.0m and the maximum was 3.0m. On the second floor, ceiling height ranged from 2.0 to 2.7m. The construction cost in the two-storey systems were $700\~140$, and sidewall curtain systems were $30\~40$ thousand Won/pyung.

  • PDF

Aerodynamic Approaches for Estimation of Waste Disease Spread in Pig Farm through Airborne Contaminants (양돈장의 소모성질병 확산 분석을 위한 현장 모니터링 및 공기유동학적 분석)

  • Seo, Il-Hwan;Lee, In-Bok;Moon, Oun-Kyung;Kwon, Kyeong-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • Pig chronic wasting disease, including porcine reproductive and respiratory syndrome (PRRS) and postweaning multisystemic wasting syndrome (PMWS), have made a continuous economic damage in pig farms. Airborne spread of livestock viruses are an important spread factor which is difficult to analyze due to invisible airflow and limitation of measurement. The objective of this study is to analyze airborne disease spread between buildings in the experimental pig farm by means of field experiment and computational fluid dynamics (CFD). The field experiments were conducted to capture airborne virus using air sampler and teflon filter along multi points in the experimental pig farm. The samples were tested in terms of virus detection resulting in positive reaction for PRRS and PCV-2 viruses, which can be a firm evidence of airborne virus spread. The CFD simulation model was developed by considering complex topography, wind conditions, building arrangement, and ventilation systems and was used to analyze airborne virus spread according to different wind conditions. The CFD computed result showed a possibility of airborne virus spread via livestock aerosol from infected pig house to neighboring pig houses according to wind directions. The CFD simulation technique is expected to provide significant data for estimating and making a counterplan against airborne disease spread.

Estimation of Particulate Matter and Ammonia Emission Factors for Mechanically-Ventilated Pig Houses (강제환기식 양돈시설의 암모니아 및 미세먼지 배출계수 산정)

  • Park, Jinseon;Jeong, Hanna;Hong, Se-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.6
    • /
    • pp.33-42
    • /
    • 2020
  • Emission factors for ammonia and particulate matters (PMs) from livestock buildings are of increasing importance in view of the environmental protection. While the existing emission factors were determined based on the emission inventory of other countries, in situ measurement of emission factors is required to construct an accurate emission inventory for Korea. This study is to report measurements of ammonia and PMs emissions from mechanically-ventilated pig houses, which are common types of pig barns in Korea. Ventilation rates and concentrations of ammonia and PMs were measured at the ventilation outlets of a weaner unit, a growing pig unit and a fattening pig unit to calculated the emission factors. The PMs emission was characterized with different aerodynamic diameters (PM2.5, PM10, and total suspended particulates (TSP)). The measured ammonia emission factors for weaners, growing pigs and fattening pigs were 0.225, 0.869 and 1.679 kg animal-1 yr-1, respectively, showing linear increase with pigs' age. The PMs emission factors for three growing stages were 0.023, 0.237 and 0.241 kg animal-1 yr-1, respectively for TSP, 0.017, 0.072 and 0.223 kg animal-1 yr-1, respectively for PM10, and 0.011, 0.016 and 0.151 kg animal-1 yr-1, respectively for PM2.5. PMs emissions were increased with pigs' age due to increasing feed supply and animal movement. The measured emission factors were smaller than those of the existing emission inventory indicating that the existing ones overestimate the emissions from pig buildings and also suggesting that long-term in situ monitoring at various livestock buildings is required to construct the accurate emission inventory.

A Farm Scale Study on the Modified Ventilation System for Improving Environmental Factors in a Confined Nursery Pig Building (무창자돈사의 환경요인 개선을 위한 변형환기시스템의 현장 평가 연구)

  • Kim, H.T.;Ko, H.J.;Kim, K.Y.;Nishizu, T.;Choi, H.L.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.175-181
    • /
    • 2006
  • Nursery pig building is imperative to provide environmental conditions favorable to maintenance of piglet health and the efficiency of growth rate. To meet the ultimate goal, it is necessary to apply proper ventilation design and construction to a confinement livestock building. This study was conducted to investigate the performance of a modified ventilation system in terms of devised slot-inlet (modification I) and exhaust fan (modification II) to improve air change rate in a confined nursery pig building, with dimension of 5.9 m(W) ${\times}$ 12.6 m(L) ${\times}$ 2.2 m(H) in an Darby Genetic Station. The experiment was carried out in August, especially when the outdoor peak temperature were above $30^{\circ}C$ and the measured indoor environmental factors were temperature, air velocity, humidity and ammonia concentration which have been known to affect the piglet health and growth. There was no difference in indoor temperature between the original and modified ventilation systems, however the air velocity and ammonia concentration in confined nursery pig building with modified ventilation system were, in most cases, better performance than original ventilation system. Therefore, it was concluded that the slot-inlet system that kept indoor environmental factors pertinent and had an economic advantage, should be considered as a ventilation system for decreasing sensible heat from piglet in confined nursery pig building during extreme summer season.

Effects of Enzyme Complex on Odor Emission from Swine Slurry and Swine Buildings (효소복합체가 양돈슬러리 및 돈사 악취발생에 미치는 영향)

  • Jung, K.H.;Han, J.C.;Kwack, S.J.;Jung, J.D.;Lee, J.W.;Kim, D.H.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • This study was carried out to investigate the effect of enzyme complex on odor emission from swine slurry and the process of making swine liquid manure. Ammonia and hydrogen sulfide concentrations were significantly decreased by using the enzyme complex of liter per ton level of liquid swine slurry in the manure storage tank according to the time. Characteristics of liquid swine slurry were affected by the enzyme complex, total nitrogen and ammonia nitrogen contents were reduced compare with control. Ammonia and hydrogen sulfide concentrations in the finishing pig building and offensive odor compound on the boundary line of swine farm were significantly decreased by spraying in swine finishing building. In conclusion, the results obtained from this study suggest that using the enzyme complex of liter per ton level of liquid swine slurry for making liquid swine manure may improve the quality of swine liquid fertilizer and reduce odor emission. Also farm scale enzyme complex treatment may improve air quality in finishing pig building and deduce offensive odor compound of swine farm.

  • PDF