Evaluation of Image Quality and dose with the Change of kVp and BMI in the Liver CT (CT 검사 시 관전압과 BMI 변화에 따른 화질 및 피폭평가)

  • Kim, Dong-Hyun;Ko, Sung-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Choi, Seok-Yoon;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.331-338
    • /
    • 2013
  • CT for follow-up visits because of liver disease, body mass index (BMI) and kVp according to the change of the image quality and radiation dose to evaluate for changes. March 2010 to June 2011 at Pusan P University Hospital, abdominal CT scans a patient BMI (Body Mass Index. Less BMI) index was less than 25 in the treatment of subjects had a 48-person Noise and SNR at 100kVp abdominal image is lager than the 120kVp image. CTDI volume value at by the analysis of the radiation dose is 4.47mGy(100kVp) and 9.01mGy(120kVp). So CTDIvol in 100kVp is smaller than CTDIvol in 120kVp(decrease by 44.1%). And, effective dose is 7.1mSv(100kVp) and 12.51mSv(120kVp). So effective dose in 100kVp is smaller than effective dose in 120kVp(decrease by 43%). Evaluation of image quality is that Unacceptable 0 person, Suboptimal 0 person, Adequate 0 person, Good 1 person, Excellent 47 person. In case of repeatly patient, we examinate abdomianl CT scan by using low kVp and body mass index less than 25. We can has good quality image and benefit of low radiation dose.

The Study of Patient Dose Comparison on Liver Computed Tomography : For 4 Equipment Vendors (간 전산화단층촬영 시 환자 선량 비교 연구 : 4개 장비회사를 대상으로)

  • Joo, Young-Cheol;Lim, Chung-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.215-216
    • /
    • 2013
  • 본 연구는 간 CT검사를 받은 환자의 선량 및 일반적 정보를 이용하여 후향적으로 진행된 연구로서, 우리나라에서 사용 빈도가 높은 4개사의 CT장비에서 각 장비별로 간 CT검사 시 환자가 받는 평균유효선량의 차이를 알아보고, 성별, 연령, 신장, 체중과 같은 환자의 특성에 따라 장비사별 환자선량을 비교 분석을 통해 임상에서 각자의 장비를 이용하여 방사선사가 간 CT검사를 진행하거나 새로운 검사조건 설정 시 환자선량 감소를 위해 고려해야 할 사항을 제시하는데 목적이 있다.

  • PDF

Effect of Extended Field of View on Measurements of Standardized Uptake Value in PET/CT (PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향)

  • Park, Soon-Ki;Nam, Ki-Pyo;Kim, Kyeong-Sik;Shin, Sang-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of extended CT field of view (FOV) on PET/CT of Standardized uptake value (SUV) when imaging extends beyond the CT FOV. Materials and Methods: CT images were reconstructed at different FOV sizes (500 and 700 mm). Two sets of CT images were reconstructed from the CT projection data by using two FOV sizes. Twenty patients were used in this study. PET images were reconstructed using attenuation maps with 500 mm CT FOV and 700 mm extended CT FOV images. Region of interests (ROIs) drawn on the PET images. In addition, twenty patients' PET images reconstructed by 500 mm CT FOV and 700 mm extended CT FOV were compared with $SUV_{max}$. Results: When using attenuation maps with 700 mm extended CT FOV, the $SUV_{max}$ analysis of liver (p=0.000), lung (p=0.007), mediastinum (p=0.001) were statistically significant. Conclusions: 700 mm extended CT FOV helps to recover the true activity distribution in the PET emission data. In addition, 700 mm extended CT FOV has affected SUV measurement of liver, lung, mediastinum.

  • PDF

Liver Tumor Detection Using Texture PCA of CT Images (CT영상의 텍스처 주성분 분석을 이용한 간종양 검출)

  • Sur, Hyung-Soo;Chong, Min-Young;Lee, Chil-Woo
    • The KIPS Transactions:PartB
    • /
    • v.13B no.6 s.109
    • /
    • pp.601-606
    • /
    • 2006
  • The image data amount that used in medical institution with great development of medical technology is increasing rapidly. Therefore, people need automation method that use image processing description than macrography of doctors for analysis many medical image. In this paper. we propose that acquire texture information to using GLCM about liver area of abdomen CT image, and automatically detects liver tumor using PCA from this data. Method by one feature as intensity of existent liver humor detection was most but we changed into 4 principal component accumulation images using GLCM's texture information 8 feature. Experiment result, 4 principal component accumulation image's variance percentage is 89.9%. It was seen this compare with liver tumor detecting that use only intensity about 92%. This means that can detect liver tumor even if reduce from dimension of image data to 4 dimensions that is the half in 8 dimensions.

Role of Whole Body FDG-PET in the Diagnosis of Hidden Distant Metastasis before Liver Transplantation in Patients with Primary Liver Cancer (고식적 검사로 간외 전이를 진단하지 못한 원발성 간암 환자에서 간이식 전에 시행한 전신 FDG-PET의 역할)

  • Lee, Won-Woo;Ryu, Jin-Sook;Yang, You-Jung;Kim, Jae-Seung;Yeo, Jeong-Seok;Moon, Dae-Hyuk;Lee, Sung-Gyu
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.368-380
    • /
    • 2002
  • Purpose: Liver transplantation (LT), one of the therapeutic options of primary liver cancer has been suffering from recurrence caused by metastasis in 8-54% of patients. This study was performed to investigate whether FDG-PET is useful for detecting hidden metastasis in LT candidates. Materials and Methods: Twenty-six patients (male:female=23:3, mean age 55.7 years) underwent FDG-PET. Their previous conventional diagnostic studies (CDS) like abdomen US and CT, chest x-ray and CT, and bone scan were negative (n=22) or equivocal (n=4) for metastasis. Positive FDG-PET findings were confirmed by biopsy or clinical follow-up. Results: Among 4 patients with equivocal metastatic lesions on CDS, 3 had 6 hypermetabolic lesions on FDG-PET, which were confirmed as metastasis and subsequently LTs were cancelled. Of these, 5 lesions were initially negative on CDS. Remained 1 patient underwent LT with a negative FDG-PET result. Among 22 patients without metastasis on CDS, 5 had 7 hypermetabolic lesions on FDG-PET. One of these patients proved to have 2 metastatic lesions, and LT was cancelled. The other 4 patients had S hypermetabolic lesions on FDG-PET, which were confirmed as benign lesions, and 3 patients of them underwent LT. In summary, FDG-PET was useful in avoiding 4 unwarranted LT by detecting unsuspected metastatic lesions on CDS. A total of 17 patients underwent LT. In comparison with pathology, the sensitivity and specificity of FDG-PET for detecting viable primary liver cancer were 55.6% (5/9) and 87.5% (7/8), respectively. Conclusion: FDG-PET can detect additional hidden metastasis and contribute to reducing unwarranted LT in the patients with primary liver cancer.

Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

Computed Tomographic Features of Blunt Abdominal Trauma in a Dog (개에서 컴퓨터단층촬영을 이용한 복부 장기 열상 진단 1례)

  • Park, Hyun-young;Seo, Ji-won;Lee, Young-won;Choi, Ho-jung
    • Journal of Veterinary Clinics
    • /
    • v.33 no.1
    • /
    • pp.39-42
    • /
    • 2016
  • A 10 months old, male Poongsan dog was referred with a history of right forelimb lameness due to hit by a car a few hours before presentation. On the physical examination, the dog showed pale mucous membrane, respiration distress, and skin abrasions. The main laboratory finding was leukocytosis, while hematocrit was normal. Abdominal radiography revealed the loss of abdominal serosal detail, which was diagnosed as peritoneal hemorrhage on ultrasonography (US) and aspiration. On computed tomography (CT), hepatic and splenic injuries were seen characterized by the discontinuity of the capsule with irregular margin and lower density lesions than parenchyma. No contrast enhancing area were shown in the laceration lesion. The accessory spleen was incidentally found by US and CT. In this case, acute intra-abdominal hemorrhage from splenic and hepatic laceration was diagnosed using CT.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.173-182
    • /
    • 1999
  • Contrast-enhanced CT has an important role in assessing liver lesions, the optimal protocol to get most effective result is not clear. The mein goal when deciding injention protocol is to optimize lesion detectability with rapid scanning when lesion to liver contrast is maximum. For this purpose, we developed a physiological model of the contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver is achieved in two paths. This dual supply characteristic distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and to second, by portal vein. However, it is assumed that only gepatic artery can supply blood to hepatocellular carcinoma(HCC) compartment, thus, the difference of contrast enhancement is resulted between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using the computer program Matlab, CT contrast-enhancement curves were simulated. The simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with the mean enhancement curves from 24 patients exposed to the same protocols as the simulation. These enhancement curves showed a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and the effects were analyzed. The variables to be considered in the injection protocol were injection rate, dose, and concentration of contrast material. These data may help to optimize scanning protocols for better diagnosis.

  • PDF

Gallbladder Agenesis in a Miniature Pinscher : Computed Tomographic and Ultrasonographic Features (담낭 무형성을 가진 미니어쳐 핀셔에서 컴퓨터단층촬영과 초음파 특징)

  • Kim, Seung-Gon;Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.111-114
    • /
    • 2013
  • A 4-year-old spayed female Miniature Pinscher was presented with a 3.5-year history of elevated liver enzymes level. Continuous elevation of liver enzymes was found on repeated blood examinations and the dog was referred for further evaluation. The abdominal ultrasonography revealed that the gallbladder could not be visualized in any plane. The absence of gallbladder was suspected on ultrasonography. Computed tomography (CT) confirmed gallbladder agenesis (GBA). This is the first reported case of diagnosis of GBA in Miniature Pinscher by using CT.

Usefulness of Scan Position Change on Dual Time Point PET-CT in Pancreas Cancer (췌장암 Dual Time Point PET/CT 검사에서 Scan Position Change의 유용성 평가)

  • Chang, Boseok;Kim, Jae Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.299-305
    • /
    • 2016
  • Despite of the development of medical equipments and technology. Pancreatic cancer has maked high false positive rate and low survival rate compared to other cancers. Therefore, early catch of pancreatic cancer is the only way to enhance the viability. It is important to find the exact location of the pancreas cancer in early stage. The method of optimum scan for early detection of pancreatic cancer on PET/CT exam is proposed. Examined the anatomical region that potentially can be missing from the supine position of ordinary pet/ct exam. The characteristics and usefulness of angle variation ($0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$) of patients scan position is analyzed. The proposed scan method (named JJ-projection) is bringing advantage of anatomical discrimination by separating stomach, liver, gallbladder duodenum and pancreas. ROC curve analysis is shows to advantage of the JJ-Projection method. The sensitivity has increased 4.6% than the supine delay scan method, the results sensitivity has increased from 91% to 95.2%. The specificity has increased from 75.1% to 84%. Compared with the results observed in cancer by biological biopsy, The accuracy has increased from 86.8% to 94.1%.