• Title/Summary/Keyword: Liver CT 검사

Search Result 109, Processing Time 0.029 seconds

Comparison of Image Quality and Dose between Intra-Venous and Intra-Arterial Liver Dynamic CT using MDCT (MDCT를 이용한 역동적 간 컴퓨터단층촬영 검사에서 정맥과 동맥 주입법에 따른 영상의 화질 및 선량 비교)

  • Ji-Young, Kim;Ye-Jin, Cho;Hui-Hyeon, Im;Ju-Hyung, Lee;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.123-129
    • /
    • 2023
  • The purpose of this study was to analyze differences in imaging quality and dose difference between intra-venous (IV) and intra-arterial (IA) liver dynamic computed tomography (CT). Herein, retrospective, blinded analysis was conducted to analyze signal-to-noise and contrast-to-noise ratios in cases of patients who underwent IV or IA liver dynamic CT for transarterial chemoembolization (TACE), an interventional procedure for hepatocellular carcinoma. The dose length product (DLP) value stored in Picture Archive and Communication System (PACS) was used to calculate the effective dose and thereby compare differences in the dose between the two methods. The mean liver and spleen signal to noise ratio (SNR) was greater in IV-liver dynamic CT than in IA-liver dynamic CT; however, contrast to noise ratio (CNR) was higher in IA-liver dynamic CT than in IV-liver dynamic CT. However, there were no differences in DLP and effective dose between the two methods. In conclusion, our findings showed that IA-liver dynamic CT showed a similar effective dose and superior CNR compared with IV-liver dynamic CT. Further studies must analyze 3D angiography CT of the hepatic artery to clearly distinguish the feeding artery, which is the essential step in interventional procedures for hepatocellular carcinoma.

Fatty Liver Diagnostics from Medical Examination to Analyze the Accuracy Between the Abdominal Ultrasonography and Liver Hounsfield Units (건강검진에서 지방간 진단의 상복부초음파검사와 간 Hounsfield Units 측정값과의 정확성 분석)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.229-235
    • /
    • 2017
  • In abdominal Ultrasonography, the fatty liver is diagnosed through hepatic parenchymal echo increased parenchymal density and unclear blood vessel boundary, and according to many studies, abdominal Ultrasonography has 60~90% of sensitivity and 84~95% of specificity in diagnosis of fatty liver, but the result of Ultrasonography is dependent on operators, so there can be difference among operators, and quantitative measurement of fatty infiltration is impossible. Among examinees who same day received abdominal Ultrasonography and chest computed tomography (CT), patients who were diagnosed with a fatty liver in the Ultrasonography were measured with liver Hounsfield Units (HU) of chest CT imaging to analyze the accuracy of the fatty liver diagnosis. Among 720 subject examinees, those who were diagnosed with a fatty liver through abdominal Ultrasonography by family physicians were 448, which is 62.2%. The result of Liver HU measurement in the chest CT imaging of those who were diagnosed with a fatty liver showed that 175 out of 720 had the measured value of less than 40 HU, which is 24.3%, and 173 were included to the 175 among 448 who were diagnosed through Ultrasonography, so 98.9% corresponded. This indicates that the operators' subjective ability has a great impact on diagnosis of lesion in Ultrasonography diagnosis of a fatty liver, and that in check up chest CT, under 40 HU in the measurement of Liver HU can be used for reference materials in diagnosis of a fatty liver.

Diagnosis of Fatty Liver Complicated by Simple Obesity in Children: Serum ALT and Its Correlation with Abdominal CT and Liver Biopsy (소아의 단순성 비만증에 의한 지방간의 진단: ALT치와 복부 전산화단층촬영 및 간생검 소견간의 상관관계)

  • Lee, Seong-Hee;Kim, Hwa-Jung;Oh, Jae-Cheol;Han, Hae-Jeong;Kim, Hee-Sup;Tchah, Hann;Park, Ho-Jin;Shin, Mi-Keong;Lee, Min-Jin;Lee, Sang-Chun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.2 no.2
    • /
    • pp.153-163
    • /
    • 1999
  • Purpose: The purpose of our study is to provide useful information for diagnostic methods of fatty liver by childhood simple obesity and to provide correlation between serum alanine aminotransferase (ALT) for screening test and abdominal computerized tomography (CT) and liver biopsy for confirmative diagnostic methods of fatty liver. Methods: Among 78 obese childrens who visited our hospital, CT was carried out in 26 childrens. Of these, liver biopsy was carried out in 15 childrens who had high obesity index or severe elevated ALT. Based on the level of serum ALT, 26 cases were classified into 3 groups, and compared with physical measurements and degree of fatty infiltration on CT and liver biopsy. Results: 1) Correlation between ALT and physical measurements: Of 26 obese children, ALT was abnormally elevated (>30 IU/L) in 17 cases (67.4%) but there was no significant correlation between ALT and physical measurements (p>0.05). 2) Correlation between degree of fatty infiltration on CT and ALT: Of 26 cases, 13 cases (50%) revealed fatty liver on CT. The degree of fatty liver on CT had significant correlation with elevation of ALT (p<0.05). 3) Correlation between the degree of fatty infiltration on liver biopsy and ALT: Liver biopsy was performed in 15 cases of which 14 cases revealed fatty liver. But one case had normal hepatic histology with severe obesity and normal ALT. Fourteen fatty liver cases on liver biopsy were classified into 3 groups by the degree of fatty infiltration and analysed with obesity index and ALT. The histologic hepatic steatosis had no significant correlation with obesity index (p>0.05), but significant correlation with ALT (p<0.05). 4) Correlation between CT and liver biopsy finding: Both CT and liver biopsy were performed in 15 cases of which 6 cases revealed normal finding on CT and 9 cases manifested fatty liver. There was significant correlation between CT and liver biopsy findings (r=0.6094). Conclusion: The results of our study suggest that abdominal CT and liver biopsy are useful and accurate methods of estimating fatty liver in the childhood obesity. But biochemical abnormalities of routine liver function tests dot not correlate well with severity of the fatty liver and liver injury.

  • PDF

Relationship between 18FDG Uptake Rate and CT Number in Fatty Liver on PET-CT (PET-CT 검사에서 지방간의 18FDG 섭취율과 CT Number의 관련성 연구)

  • Lee, Eun-Hyeng;Seok, Jong-Min;Jeon, Woo-Jin;Ko, Eun-Ju;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.159-165
    • /
    • 2018
  • The purpose of this study is to provide the basic information for diagnosis and treatment of fatty liver by investigating the relationship of the body $^{18}FDG$ uptake and CT Number in patients with fatty liver. This study was conducted on patients who were admitted to the N hospital from January 2014 to October 2015 underwent PET-CT. This result, the probability of fatty liver was 5 times higher in male. The $^{18}FDG$ uptaking were increased by more than 1.000 times respectively in the Liver RT, Middle liver, Liver LT from patients with fatty liver (p <.05). And the CT Number were decreased by 0.93, 0.88, and 0.92 times respectively in Liver RT, Middle liver, Liver LT from patients with fatty liver (p <.05). In conclusion, significant changes of $^{18}FDG$ uptake rate and CT number according to fatty liver provide reliable information for diagnosis and treatment of fatty liver patients. And it can be used as a basic data for the study of fatty liver predictability.

Diagnostic Imaging of Liver Cirrhosis in a Shih-Tzu Dog (시츄견에서 발생한 간경화의 영상 진단)

  • Choi, Ho-Jung;Lee, Ki-Ja;Chang, Jin-Hwa;An, Ji-Young;O, I-Se;Ahn, Se-Joon;Jeong, Seong-Mok;Park, Seong-Jun;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.4
    • /
    • pp.367-370
    • /
    • 2009
  • A 5-year-old, intact female Shih-Tzu dog was presented with 1 year history of icterus, ascites and anorexia. The serum biochemistry revealed elevated liver enzyme levels. Microhepatica and decreased serosal detail were detected in abdominal radiography. Abdominal ultrasonographic findings included irregular liver margins, multifocal hypoechoic nodules in the liver parenchyma, and ascites. Computed tomography (CT) showed multifocal hypodense nodules with ring-like contrast enhancement. Cytologic and histopathologic examination by liver core biopsy revealed fibrosis. Cirrhosis was diagnosed based on above results. This report focuses on the imaging characteristics of ultrasonography and CT for liver cirrhosis in a dog.

The Objective Image Analysis for HCC and HH with a Axial Image of Liver CT Scan (Liver CT 단면영상에서 간세포암과 간혈관종의 객관적 영상분석)

  • Hwang, In-Gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.411-417
    • /
    • 2015
  • To distinguish between HCC and HH is one of the important test methods in determining the treatment method by determining the treatment method by distinguishing malignant growth and benign tumors in liver CT scan. Currently, the specialist is reading CT images by their subjective judgment. So, the purpose of this study is to treat reading the CT images even more objective way. The test times after injection contrast medium in this study are the before injection phase(Pre.), artery phase(35sec), portal phase(70sec) and delay phase(180sec). The general pattern change of HCC in change of contrast enhancement pattern shows 26.6% matching. And the case of HH shows 16.6% matching. In order to observe the change of HU value between HCC and HH, each average values and standard deviation was confirm and as a result, it shows the lagre difference between artery and portal phase in lesion.(HCC$19.76{\pm}23.52$, HH$60.23{\pm}29.43$). And it shows the 76.6% matching in HCC and 80.0% matching in HH. Thorough this study, to suggest a HU value as objective analysis method and if the anlaysis method was used in clinical will assist in the diagnosis.

The evaluation of useful on the additional PET/CT Liver scan (PET/CT 검사에서 Gastrointestinal Cancer 환자의 Liver 추가촬영에 대한 유용성 평가)

  • Park, Se Youn;Lee, Hwa Jin;Lee, Mu Seok;Kim, Jung Uk;Ji, Hye In
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.46-48
    • /
    • 2016
  • Purpose The liver one of the most common site for distant metastasis for a variety of tumor, especially of gastrointestinal origin. the purpose of this study was to analyze image quality between standard scan and additional liver scan. Materials and Methods From September 2015 to February 2016. 152 patients were examined undergo gastrointestinal cancer. 32 patients confirmed liver metastasis analyzed same liver ROI level and check the SNR, SUV and T/N ratio Results The $SNR_{mean}$ of standard was $17.7{\pm}10.3$; addition was $22.3{\pm}9.7$ (p<0.05). In $SUV_{max}$ of standard was $6.7{\pm}2.8$; addition was $7.6{\pm}3.2$ (P<0.05). and the T/N ratio of standard was $2.1{\pm}0.6$; addition was $2.5{\pm}0.8$ (P<0.05). Conclusion The $SNR_{mean}$, $SUV_{max}$ and T/N ratio were higher than those on the first scan (P<0.05). The SNRmean showed the highest change rate among the parameters. A additional liver scan is more favorable for the detection of gastrointestinal cancer patients.

  • PDF

The methods of distinguishing between HCC and HH in Liver CT scan (Liver CT 영상에서 간세포암과 간혈관종 구별에 대한 연구)

  • Hwang, In-gil;Ko, Seong-Jin;Choi, Seok-Yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.173-174
    • /
    • 2015
  • 간에서 발생하는 악성종양과 양성종양의 대표적 질환 으로는 간세포암(Hepatocelluar carci- noma, HCC)과 간혈관종(Hepatic hemangioma, HH)이다. CT검사를 이용한 진단에 있어서 두 질환은 시간변화에 따른 조영증강양상 차이가 나타난다. Liver 3-phase computed tomography검사를 시행하여 시간별 조영증강 양상을 알아보았다. 본 연구는 조영제 주입전, 동맥기(35sec), 문맥기(70sec), 지연기(180sec)에 대한 Enhan -cement Pattern 변화와 HU(Hounsfield unit)값 변화, pixel값 변화의 관찰로서 검증하였다. 실험결과 HU를 사용한 방법에서 의미있게 구분되었고 임상적용 시 판독에 도움을 줄 것으로 생각한다.

  • PDF

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners (PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가)

  • Park, Seung-Yong;Ko, Hyun-Soo;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Purpose: Facilities use own sever or mini PACS system for storage and analysis of the PET/CT data. Mini PACS can storage scan data as well as measuring SUV. Therefore, the study was performed to confirm whether or not measured SUV on mini PACS is measured equally on PET/CT workstation. Materials and Methods: In February 2011, 30 patients who were performed $^{18}F$-FDG wholebody PET/CT scan in Biograph 16, Biograph 40 and Discovery Ste 8 were enrolled. First, using each workstation, SUV in liver and aorta of mediastinum level was measured. Second, using mini PACS, SUV was measured by same method. Result: The correlation coefficient of SUV in liver between PET/CT scanner and min PACS in Biograph 16, Biograph 40, Discovery Ste 8 was 0.99, 0.98, 0.64 respectably, the correlation coefficient of SUV in aorta was 0.98, 0.98, 0.66, and these were showed positive correlation coefficient. Difference of SUV between Biograph workstation and mini PACS was not showed statistical significant difference at 5% level of significance. Difference of SUV between Discovery Ste 8 workstation and mini PACS was showed statistical significant difference at 5% level of significance. Conclusion: In case that patient was scanned by the other scanner, if the correction of SUV formula in mini PACS for each scanners is performed, mini PACS will be usefully used to provide consistently quantitative assessment.

  • PDF