• 제목/요약/키워드: Liquid sensor

검색결과 316건 처리시간 0.026초

Electrochemical Determination of Capsaicin by Ionic Liquid Composite-Modified Electrode

  • Kim, Dong-Hwan;Nam, Sungju;Kim, Jaeyoon;Lee, Won-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권2호
    • /
    • pp.177-184
    • /
    • 2019
  • An electrochemical detection method for capsaicin has been developed using ionic liquid (IL) doped graphene-titania-Nafion composite-modified electrode. The combination of IL (1-hexyl-3-methylimidazolium with hexafluorophosphate counter ion) in the composite-modified electrode resulted in a significantly increased electrochemical response for capsaicin compared to that obtained at the corresponding electrode without IL. The increased electrochemical signal could be ascribed to the decreased electron transfer resistance through the composite film and also to the effective accumulation of capsaicin on the electrode surface due to ${\pi}-{\pi}$ interaction of the imidazole groups of IL with the aromatic rings of capsaicin. The present IL composite-modified electrode can detect capsaicin with a concentration range from $3.0{\times}10^{-8}M$ to $1.0{\times}10^{-5}M$ with a detection limit of $3.17{\times}10^{-9}M$ (S/N = 3). The present sensor showed good reproducibility (RSD = 3.2%).

New generation of imaging colorimeter and imaging polarimeter

  • Boher, Pierre;Leroux, Thierry;Glinel, David
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.453-456
    • /
    • 2009
  • We present a new generation of imaging colorimeter that ensures improved accuracy and sensitivity for shorter measurement times. The imaging optics is telecentric on the sensor and allows measurements at any distances without additional calibration. A new technology is used to make the color filters and flat densities. Imaging polarimetry at fixed wavelength is also possible with the same instrument.

  • PDF

다중센서 양변기에 관한 연구 (A Study on the Multi-sensor Toilet)

  • 임정빈;박남기;최보겸;김연경;김재욱
    • 한국전자통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.201-206
    • /
    • 2022
  • 본 논문은 변기 커버 자동 개폐식 기능을 갖춘 물 내림 시스템을 연구하였다. 커버 위에 부착된 적외선 센서의 감지 여부에 따라 작동하게 된다. 열림 기능의 적외선 센서가 감지 되면 변기 커버의 서보모터를 구동시켜 커버를 올리도록 설정하였고, 닫힘 기능의 적외선 센서가 감지되면 커버를 내리도록 설정하였다. 커버 내부에 기울기 센서를 달아서 커버가 내려가는 것에 동작하도록 설정한 뒤 이것이 작동되면 변기 레버와 연결되어 있는 서보모터가 공급 구의 마개를 열어 물을 내려보내는 방식이다. 또한, 물을 내려보내는 과정 중에서 물이 막혔을 때 알리기 위한 비접촉 수위센서와 LED 기능을 이용해 다음 사용자가 양변기를 이용할 때 겪을 수 있는 불펀을 최소화하였고, 변기가 닫혀있는 동안 세균 증식을 막기 위해 UV-LED 기능도 구현하였다.

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..

Multianalyte Sensor Array using Capillary-Based Sample Introduction Fluidic Structure: Toward the Development of an "Electronic Tongue"

  • 손영수
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.378-382
    • /
    • 2004
  • A micromachined fluidic structure for the introduction of liquid samples into a chip-based sensor array composed of individually addressable polymeric microbeads has been developed. The structure consists of a separately attached cover glass, a single silicon chip having micromachined channels and microbead storage cavities, and a glass carver. In our sensor array, transduction occurs via colorimetric and fluorescence changes to receptors and indicator molecules that are covalently attached to termination sites on the polymeric microbeads. Data streams are acquired for each of the individual microbeads using a CCD. One of the key parts of the structure is a passive fluid introduction system driven only by capillary force. The velocity of penetration of a horizontal capillary for the device having a rectangular cross section has been derived, and it is quite similar to the Washburn Equation calculated for a pipe with a circular cross section having uniform radius. The test results show that this system is useful in a ${\mu}$-TAS and biomedical applications.