• Title/Summary/Keyword: Liquid line

Search Result 537, Processing Time 0.035 seconds

Moment Evaluations of Gimbal Expansion Joints for Liquid Rocket Engine Propellant Pipes (액체로켓엔진 배관 김발 신축 이음 모멘트 평가)

  • Yoo, Jaehan;Moon, Ilyoon;Lee, Soo Yong;Choi, Chunghyeon
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.105-110
    • /
    • 2013
  • The gimbal expansion joint for the pipe line of a liquid rocket engine undergoes high pressure and cyclic rotational displacement loadings. In present study, the moment analyses and tests of the internal-type gimbal expansion joint for the engine were performed. The moment components due to spring stiffness, friction and lateral force were obtained using a analytic method and their sums at low and high pressures were compared with the test results. Also, applying a $MoS_2$ dry film lubricant to the pin of a external hinge expansion joint, it is tested that the galling of the pin was removed and the friction coefficient was decreased for low pressures.

Performance test and uncertainty analysis of the FBG-based pressure transmitter for liquid metal system

  • Byeong-Yeon KIM;Jewhan LEE;Youngil CHO;Jaehyuk EOH;Hyungmo KIM
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4412-4421
    • /
    • 2022
  • The pressure measurement in the high-temperature liquid metal system, such as Sodium-cooled Fast Reactor(SFR), is important and yet it is very challenging due to its nature. The measuring pressure is relatively at low range and the applied temperature varies in wide range. Moreover, the pressure transfer material in impulse line needs to considered the high temperature condition. The conventional diaphragm-based approach cannot be used for it is impossible to remove the effect of thermal expansion. In this paper, the Fiber Bragg Grating(FBG) sensor-based pressure measuring concept is suggested that it is free of problems induced by the thermal expansion. To verify this concept, a prototype was fabricated and tested in an appropriate conditions. The uncertainty analysis result of the experiment is also included. The final result of this study clearly showed that the FBG-based pressure transmitter system is applicable to the extreme environment, such as SFR and any other high-temperature liquid metal system and the measurement uncertainty is within reasonable range.

Metallizations and Electrical Characterizations of Low Resistivity Electrodes(Al, Ta, Cr) in the Amorphous Silicon Thin Film Transistor (비정질 실리콘 박막 트랜지스터 소자 특성 향상을 위한 저 저항 금속 박막 전극의 형성 및 전기적 저항 특성 평가)

  • Kim, Hyung-Taek
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.96-99
    • /
    • 1993
  • Electrical properties of the Thin Film Transistor(TFT) electrode metal films were investigated through the Test Elements Group(TEG) experiment. The main purpose of this investigation was to characterize the electrical resistance properties of patterned metal films with respect to the variations of film thickness and TEG metal line width. Aluminum(Al), Tantalum(Ta) and Chromium(Cr) that are currently used as TFT electrode films were selected as the probed metal films. To date, no work in the electrical characterizations of patterned electrodes of a-Si TFT was accomplished. Bulk resistance$(R_b)$, sheet resistance$(R_s)$, and resistivities($\rho$) of TEG patterned metal lines were obtained. Electrical continuity test of metal film lines was also performed in order to investigate the stability of metallization process. Almost uniform-linear variations of the electrical properties with respect to the metal line displacements was also observed.

  • PDF

Application of On-Line SPE-LC/MSD to Measure Perfluorinated Compounds (PFCs) in Water (On-Line SPE-LC/MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Jung, Jong-Moon;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • We applied a sensitive method based on on-line solid-phase extraction (SPE) and liquid chromatography/mass spectrometry (LC/MSD) using an electrospray interface for the determination of eleven perfluorinated compounds (PFCs) in water. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 mL water samples, recoveries were between $80.4{\pm}5.2%{\sim}109.5{\pm}1.4%$ and limit of quantification (LOQ) were 3.6~15.9 ng/L for the PFCs. The total PFCs concentrations of the tributaries and main stream of Nakdong River water samples were in the range of $8.0{\sim}678.6{\mu}g/L$.

Permeation Apparatus for on-line Measurement of the Permeation Characteristics through Dense Polymeric Membranes (투과특성의 on-line 측정을 위한 투과장치)

  • 염충균;김범식;김철웅;김광주;이정민
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.86-93
    • /
    • 1998
  • A permeation apparatus has been devdoped which could make the on-line measurements of both flux and permeate composition. Pervaporative experiment of a single component, i.e. water was performed by using poly(vinyl alcohol) membrane crosslinked with glutaraldehyde to confirm the validity of the apparatus. In the experiment, steady-state permeation was obtained in 15 minutes and the measurement could be completed within 20 minutes. A comparison of the on-line measurement was made with the fluxes measured simultaneously by the conventional method in which the permeates were collected by liquid nitrogen. The on-line measurement by the apparatus showed an excellent agreement with the conventional measurement within a difference of $\pm$2%. From the flux data with operating time, 3 kinds of diffusion coefficients of water $D_{slope}, D_{1/2}$, and $D_t$ were determined, which were also coincident with values in a literature. It was confirmed that accurate measurements of fluxes could be obtained from the apparatus.

  • PDF

Salting-out Effects on the Partition of Proteins in Aqueous Two-phase Systems

  • KIM, CHAN-WHA;CHO KYUN RHA
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.5
    • /
    • pp.352-357
    • /
    • 1996
  • The partition of proteins in the salt-rich phase of polyethylene glycol (pEG)/salt aqueous two-phase systems is limited by the salting-out effects of salt. The logarithm of the concentration of proteins partitioned in the salt-rich phase decreases linearly with increases in the concentration of salt in the salt-rich phase (salting-out). Therefore, the partition of a given protein in the salt-rich phase of aqueous two-phase systems can be estimated from the salting-out constant. The slope of the solubility line (salting-out con-stant) for a given protein is determined by the type of salt in the two-phase systems.

  • PDF

Growth and Characterizations of Liquid-Phase-Epitaxial Fe doped GaAs

  • Ko, Jung-Dae;Kim, Deuk-Young;Kang, Tae-Won
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1997.06a
    • /
    • pp.253-259
    • /
    • 1997
  • The iron doped GaAs single crystals were grown by liquid phase epitaxial method and its some physical properties were evaluated with a view to investigate the crystal quality and emission property. The isomer shift of 0.303mm/sec is calculated from low-temperature M ssbauer spectroscopy and we know that charge state of iron ion is 3+ in GaAs crystal. In low temperature photoluminescence, the deep emission bands with wide-line width have been observed at 0.99eV and 1.15eV in addition to sharp excitonic peaks. We attributed that these deep emissions are originated from substitutional Fe-acceptor which has charge state of 3+ and 2+, respectively.

  • PDF

Liquid Chromatography of Non-Chromophores by Indirectly Photometric Detection (간접 분광광도 측정에 의한 비발색단의 액체크로마토그래피)

  • Sam-Woo Kang;Hae-Beom Oh;Young-Ja Moon
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.184-189
    • /
    • 1987
  • Brilliant green was examined as a detection reagent in the separation of some aliphatic alcohols, ketones and esters by the reverse-phase liquid chromatography. These samples not possessing chromophore could be indirectly detected by photometric detector with the assistance of brilliant green in visible range (625nm). Some mixtures of samples were also able to separated and detected with good base line resolution and comparatively high sensitivity.

  • PDF

Antiferroelectric Liquid Crystal Display with High Image Quality

  • Chang, Young-Joo;Yu, Jeong-Seon;Yoo, Jeong-Geun;Jeong, Dong-Jin;Park, Sung-Chon;Chae, Su-Yong;Yang, Hong-Geun
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.1-3
    • /
    • 2002
  • The antiferroelectric liquid crystal display (AFLCD) is a unique display that can at demonstrate a moving image perfectly the passive matrix driving scheme. We optimised driving the waveform and introduced a dual-driving method. Also, by improving this driving method and using line inversion method, we realize the AFLC display of high image quality with $160(RGB){\times}240$, 32768 colors, crosstalk free and flicker free contrast ratio is greater than 60:1, and the brightness is above 200 $cd/m^2$.

Water Tests of Fuel Pump for 75-ton Class Liquid Rocket Engine (75톤급 액체로켓엔진용 연료펌프의 수류시험)

  • Kim, Dae-Jin;Choi, Chang-Ho;Hong, Soon-Sam;Kwak, Hyun-D.;Kim, Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.61-65
    • /
    • 2011
  • A series of water tests of a fuel pump for liquid rocket engines are performed at a room temperature. According to the test results, the head coefficient of the pump follows the conventional similarity rule - unlike this, the pump shows better efficiency with higher rotational speed. Also, it is found that the pressure at the rear bearing outlet is higher than expected because the inlet of bypass pipe line is narrow. Furthermore, the cavitation performance of the fuel pump is found to be sufficient for the engine operation and is better at the lower flow ratio and higher rotational speed.