• Title/Summary/Keyword: Liquid flow measurement

Search Result 242, Processing Time 0.024 seconds

Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography (중성자 래디오그래피를 이용한 액체금속 유동장 측정)

  • Cha, Jae-Eun;Saito, Yasushi
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow) (국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구)

  • 임기원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

Application of DFB Diode Laser Sensor to Reacting Flow (II) - Liquid-Gas 2-Phase Reacting Flow -

  • Park, Gyung-Min;Masashi Katsuki;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.139-145
    • /
    • 2003
  • Diode laser sensor is conducted to measure the gas temperature in the liquid-gas 2-phase counter flow flame. C$\_$10/H/ sub 22/ and city gas were used as liquid fuel and gas fuel, respectively. Two vibrational overtones of H$_2$O were selected and measurements were carried out in the spray flame region stabilized the above gaseous premixed flame. The path-averaged temperature measurement using diode laser absorption method succeeded in the liquid fuel combustion environment regardless of droplets of wide range diameter. The path-averaged temperature measured in the post flame of liquid-gas 2-phase counter flow flame showed qualitative reliable results. The successful demonstration of time series temperature measurement in the liquid-gas 2-phase counter flow flame gave us motivation of trying to establish the effective control system in practical combustion system. These results demonstrated the ability of real-time feedback from combustor inside using the non-intrusive measurement as well as the possibility of application to practical combustion system. Failure case due to influence of spray flame was also discussed.

Liquid Atomization and Spray Characteristics in Electrostatic Spray of Twin Fluids (2유체 정전분무의 액체 미립화 및 분무 특성)

  • Kim, Jeong-Heon;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1552-1560
    • /
    • 2001
  • This paper presents the experimental results of a study undertaken to develop an electrostatic spray system for a combustion application. The characteristics of the liquid atomization and the droplet dispersion in the electrostatic spray of twin fluids were investigated by the optical measurement techniques. The processes associated with the break-up of charged jets were also observed using the laser sheet visualization. The diameter and velocity of droplets were simultaneously measured using the phase Doppler measurement technique. The electrostatic atomization of the liquid fuel depended primarily on the charging voltage and the flow rate, but the dispersion of droplets depended significantly on the aerodynamic flow. Aerodynamic influences on the liquid atomization decreased with an increase of the charging voltage. Consequently, the liquid atomization and the droplet dispersion could be independently controlled using the electrostatic and aerodynamic mechanisms.

An Experimental Study on Laminar Flow Temperature Using Thermo-sensitive Liquid Crystal (감온액정을 이용한 층류유동의 온도장에 관한 실험적 연구)

  • Chang, Tae-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.4
    • /
    • pp.373-378
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the temperature field in a two-dimensional cross section of fluid flow. This study found the temperature distribution for Re =900~1,500 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for temperature measurement and liquid crystal is used for heat transfer experiments in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

  • PDF

An Experimental Study on Laminar Flow Velocity by Using Thermo-sensitive Liquid Crystal (감온액정을 이용한 층류유동의 속도장에 관한 실험적 연구)

  • Chang, Tae-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2004
  • An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the velocity field in a two-dimensional cross section of fluid flow. This study found the velocity distributions for Re = 1,594 ~ 2,510 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for velocity measurement by using liquid crystal in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

  • PDF

Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement (다회선 초음파 유량계를 이용한 거래용 오일유량 측정)

  • Hwang, Shang-Yoon;Lee, Ho-June;Park, Ki-Hwan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF

Development of a 9as-liquid two-phase flowmeter using double orifice plates (2중판 오리피스를 이용한 기액 2상유량계의 개발)

  • 이상천;이상무;남상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.619-629
    • /
    • 1998
  • An experimental work was conducted to investigate a feasibility of simultaneous measurement of gas-liquid two-phase flowrates with double orifice plates using air and water. The tests were carried out under the atmospheric pressure and at the ambient temperature using two different tube sizes. Qualities of an air-water flow in the present study have values less than 0.1 and thus the mixed flow showed bubbly, plug, slug flow regimes. The probability density function (PDF) and the power spectral density function (PSDF) of the instantaneous pressure drop traces for the flow regimes were obtained. It is found that some distinctive features exist in the distribution of these functions, depending upon the two-phase flow pattern. The time-averaged value of the instantaneous pressure drop increases with increasing gas and liquid flowrates, showing a single-valued function for the total mass flowrate and the quality. It is also found that the two-phase discharge coefficient exhibits a consistent trend for variation of dimensionless parameters such as the superficial velocity ratio and the gas Reynolds number. The results indicate that simultaneous measurement of two-phase flowrate may be possible based upon a statistical analysis of the instantaneous pressure drop curves monitored using double orifice plates.

  • PDF

Review of Experimental Studies on Swirling Flow in the Circular Tube using PIV Technique

  • Chang, Tae-Hyun;Nah, Do-Baek;Kim, Sang-Woo
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.1
    • /
    • pp.21-28
    • /
    • 2009
  • The study of swirling flow is of technical and scientific interest because it has an internal recirculation field, and its tangential velocity is related to the curvature of streamline. The fluid flow for tubes and elbow of heat exchangers has been studied largely through experiments and numerical methods, but studies about swirling flow have been insufficient. Using the particle image velocimetry(PTV) method, this study found the time averaged velocity distribution with swirl and without swirl along longitude sections and the results appear to be physically reasonable. In addition, streamwise mean velocity distribution was compares with that of other. Furthermore, other experimental investigation was performed to study the characteristics of turbulent water flow in a horizontal circular tube by using liquid crystal. 2D PIV technique is employed for velocity measurement and liquid crystal is used for heat transfer experiments in water. Temperature visualization was made quantitatively by calibrating the colour of the liquid crystal versus temperature using various approaches.

Micro-PIV measurement of internal flow in a micro droplet

  • KINOSHITA Haruyuki;KOBAYASHI Toshio;OSHIMA Marie
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.141-145
    • /
    • 2004
  • Visualization and PIV measurements of the symmetrical recirculation flow in a nanoliter-sized droplet have been performed using the micro PIV system. The airflow sweeps over the nanoliter-sized liquid droplet fixed in a microchannel and the frictional force drags the liquid on the round interface, which causes the symmetrical recirculation flow in the droplet. The internal recirculation flow in the droplet has been visualized and measured successfully. The results of micro PIV measurement show the maximum speed of the recirculation flow is up to 10 mm/s. The high-speed recirculation can enhance a stirring effect and generate strong shear in the droplet, resulting in acceleration of mixing.

  • PDF