• 제목/요약/키워드: Liquid drop

검색결과 480건 처리시간 0.024초

Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구 (A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material)

  • 김석택
    • 한국환경과학회지
    • /
    • 제9권5호
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

액체로켓엔진 공급시스템 모듈 개발 (Development of Supply System Module for Liquid Rocket Engine)

  • 김혜민;이상복;김완조;노태성
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.79-84
    • /
    • 2010
  • 액체로켓엔진 공급시스템을 구성하는 배관, 오리피스, 굽힘관, 벨로우즈, 밸브, 플랜지 등의 공급계 부품들에 대한 액체로켓엔진 공급시스템 모듈을 개발하였다. 이 모듈은 각 부품별로 Sizing이 가능하며 압력강하를 계산할 수 있다. 또한, 공급시스템이 구성되면 시스템 전체 부품 개수, 압력강하, 출구압력, 무게를 도출할 수 있다.

  • PDF

Flow boiling of liquid nitrogen in narrow annular channels

  • Zhang P.;L., Qi S.;Z., Wang R.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권4호
    • /
    • pp.1-5
    • /
    • 2008
  • Flow and heat transfer characteristics of liquid nitrogen in narrow annular channels are very important for many practical applications. In the present study, the experimental investigation of flow boiling of liquid nitrogen in narrow annular channels with gap size of 0.2 and 0.5 mm is carried out. The pressure drop and heat transfer coefficients are experimentally measured. The comparison of the theoretical models for the pressure drop and the correlations of the flow boiling to the experimental results are carried out.

이중 스월 인젝터의 분무특성에 관한 연구 (Investigation for Spray Characteristics of Dual Swirl Injector)

  • 박희호;정충연;김유
    • 한국추진공학회지
    • /
    • 제9권1호
    • /
    • pp.17-26
    • /
    • 2005
  • 본 연구에서는 이중 스월 동축형 분사기의 운용조건인 산화제 및 연료 적용 압력, Recess에 의한 영향이 추진제의 분산각, 인젝터 출구에서의 속도성분, 오리피스에서의 액막 두께 등의 영향을 확인하여 설계에 반영할 수 있도록 비연소 시험과 아울러 분사기에서의 유동조건과 관련한 수치해석을 수행하였다. 추진제의 분산각은 적용한 압력 강하량에는 크게 변화하지 않으나 입구에서의 접선방향 속도성분비와 인젝터 형상계수에는 민감하게 반응하여 변하는 것을 알 수 있었다. 수치해석을 통한 인젝터 오리피스 내부 액막 두께 해석 및 연소실 내부 분산각 거동 해석의 타당성을 확인하였으며, 액막 두께변화에 속도성분비가 압력 강하량 변화에 비해 상대적으로 큰 영향을 미치는 것을 알 수 있었고, 속도 성분비율이 증가할수록 액막 두께가 감소하는 경향을 보였다.

Flow-3d를 이용한 표면장력 탱크용 메시 스크린 모델링 (Modeling of Mesh Screen for Use in Surface Tension Tank Using Flow-3d Software)

  • 김현탁;임상혁;윤호성;박정배;권세진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.984-990
    • /
    • 2017
  • 상용 CFD 프로그램 Flow-3d를 활용하여, 표면 장력 탱크 적용을 위한 메시 스크린의 모델링 및 추진제 배출 해석을 수행하였다. Flow-3d 내 거시적 다공성 매체 모델을 사용하였으며, $350{\times}2600$, $400{\times}3000$, $510{\times}3600$ DTW 메시 스크린에 대한 공극률, 모세관압, 항력계수를 스크린 모델에 대입 후, 기포점 측정 시뮬레이션을 수행하였다. 시뮬레이션 결과를 실험 데이터와 비교하였으며, 메시 스크린 모델링의 적절성을 검증하였다. 이를 기반으로 스크린 모델을 포함한 PMD 구조체에 대한 추진제 배출 해석을 수행하였다. 추진제는 액상의 NTO를 가정하였으며, $3{\times}10^{-3}g$ 가속 조건에서 초기 유량을 만족하도록 void를 유입시켰다. 메시 스크린을 통한 차압은 초기 약 270 Pa에서 시간에 따라 증가하였으며, 스크린 모델의 예상 기포점과 유사한 630 Pa에 이르기까지 액상 추진제 배출을 지속하였다.

  • PDF

케로신과 액체산소를 추진제로 하는 10톤급 액체로켓엔진의 재생냉각 특성 평가 (Evaluation on the Regenerative Cooling Characteristics in Liquid Rocket Engine of 10tf-thrust using Kerosene and Liquid Oxygen as a Propellant)

  • 한풍규;조원국;조용호
    • 한국항공우주학회지
    • /
    • 제32권4호
    • /
    • pp.111-117
    • /
    • 2004
  • 케로신과 액체산소를 추진제로 하며, 10톤을 설계 추력으로 하는 우주 발사체의 2단용 액체로켓엔진의 재생 냉각 특성에 대한 해석적 연구를 수행하였다. 또한 보조적인 냉각 방법으로서 노즐 확장부에는 대기로의 복사 방열에 의한 냉각을 적용하였다. 본 연구를 통해, 케로신을 연료로 하는 10톤 추력의 2단용 액체로켓엔진에서 재생냉각과 복사 냉각에 의한 냉각 기구만으로는 소재의 열 및 열구조적인 불안정성과 냉각채널에서의 과다한 압력강하에 의해 적합하지 않다는 것을 확인하였다.

아음속 수직분사제트에서 액적크기 특성에 대한 실험적 연구 (An Experimental Study on Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow)

  • 김민기;손진관;김진기;황용석;윤영빈
    • 한국분무공학회지
    • /
    • 제12권2호
    • /
    • pp.115-122
    • /
    • 2007
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomize. internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD (Sauter Mean Diameters) distribution by using Planar Liquid Laser Induced Fluorescence technique. The objectives of this research are get a droplet distributions and drop size measurements of each condition and compare with the other flow effects. As the result, This research has been showned that droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects, and normalized distance from the injector exit length(x/d, y/d). There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF

SELF-PULSATION CHARACTERISTICS OF A SWIRL COAXIAL INJECTOR WITH VARIOUS INJECTION AND GEOMETRIC CONDITIONS

  • Im, Ji-Hyuk;Kim, Dong-Jun;Yoon, Young-Bin;Bazarov, V.
    • 한국분무공학회지
    • /
    • 제10권3호
    • /
    • pp.29-37
    • /
    • 2005
  • The spray and acoustic characteristics of a gas/liquid swirl coaxial injector are studied experimentally. The self-pulsation is defined as a pressure and flow rate oscillations by a time-delayed feedback between liquid and gas phase. Self-pulsation has strong influences on atomization and mixing processes and accompanies painful screams. So. the spray and acoustic characteristics are investigated. Spray patterns are observed by shadow photography technique in order to determine the onset of self-pulsation. And self-pulsation boundary with Injection conditions and recess length is get. To measure the frequency of the spray oscillation. oscillation of the laser intensity which passes through spray is analyzed by Fast Fourier Transform. For acoustic tests, a PULSE System was used. Acoustic characteristics of a swirl coaxial injector are investigated according to the injection conditions. such as the pressure drop or the liquid and gas phase. and injector geometries. such as recess length and gap size between the inner and outer injector. Front the experimental results. the increase of recess length leads to the rapid increase of the sound pressure level. And as the pressure drop of the liquid phase increases. the frequency of the self?pulsation shifts to the higher frequency. The frequency of spray oscillations is the same as that of the acoustic fields by self-pulsation.

  • PDF

핀치이론의 수정 모델을 이용한 스프레이 모드의 해석 (Analysis of Spray Mode Using Modified Pinch Instability Theory)

  • 박아영;;김선락;유중돈
    • Journal of Welding and Joining
    • /
    • 제27권5호
    • /
    • pp.88-93
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

핀치이론의 수정 모델을 이용한 스프레이 모드의 해석 (Analysis of Spray Mode Using Modified Pinch Instability Theory)

  • 박아영;;김선락;유중돈
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.44-44
    • /
    • 2009
  • While the pinch instability theory (PIT) has been widely employed to analyze the spray transfer mode in the gas metal arc welding (GMAW), it cannot predict the detaching drop size accurately. The PIT is modified in this work to increase the accuracy of prediction and to simulate the molten tip geometry to be more physically acceptable. Since the molten tip becomes a cone shape in the spray mode, the effective wire diameter is formulated that the effective diameter is inversely proportional to current square. Modifications are also made to consider the finite length of the liquid column and current leakage through the arc. While the effective diameter influences drop transfer significantly, the current leakage has negligible effects. The effects of modifications on drop transfer are analyzed, and the predicted drop diameters show good agreements with the experimental data of the steel wire.

  • PDF