• 제목/요약/키워드: Liquid column

검색결과 1,371건 처리시간 0.028초

Innovative modeling of tuned liquid column damper controlled structures

  • Di Matteo, Alberto;Di Paola, Mario;Pirrotta, Antonina
    • Smart Structures and Systems
    • /
    • 제18권1호
    • /
    • pp.117-138
    • /
    • 2016
  • In this paper a different formulation for the response of structural systems controlled by Tuned Liquid Column Damper (TLCD) devices is developed, based on the mathematical tool of fractional calculus. Although the increasing use of these devices for structural vibration control, it has been demonstrated that existing model may lead to inaccurate prediction of liquid motion, thus reflecting in a possible imprecise description of the structural response. For this reason the recently proposed fractional formulation introduced to model liquid displacements in TLCD devices, is here extended to deal with TLCD controlled structures under base excitations. As demonstrated through an extensive experimental analysis, the proposed model can accurately capture structural responses both in time and in frequency domain. Further, the proposed fractional formulation is linear, hence making identification of the involved parameters extremely easier.

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • 제36권5호
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

Narrowbore high-performance liquid chromatographic method for the determination of cetirizine in plasma using column switching

  • Hyun, Myung-Ja;Ban, Eunmi;Woo, Jong-Soo;Kim, Chong-Kook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.398.2-398.2
    • /
    • 2002
  • A column switching HPLC assay was developed to allow the separation and quantitation of cetirizine in human plasma by ultraviolet (UV) detection. Plasma samples were prepared by liquid-liquid extraction. After drying, the residue was reconstituted in 20 mM phosphate buffer (pH 2.8) containing 15% acetonitrile. The samples were initially injected onto a clean-up Capcell Pak MF C18 column. (50 mm $\times$ 4.6 mm I.D.), and the chromatographic region containing the peaks of interest was followed in an analytical C18 microcolumn (250 mm$\times$1.5 mm I. D.) via column switching device. (omitted)

  • PDF

다양한 HPLC Column에서의 IgY(Immunoglobulin Yolk) 분리특성 (Separation Characteristics of IgY (Immunoglobulin Yolk) in Various HPLC Columns)

  • 송성문;김인호
    • Korean Chemical Engineering Research
    • /
    • 제50권4호
    • /
    • pp.659-665
    • /
    • 2012
  • 동물 혈청 중의 IgG (Immunoglobulin G)에 해당되는 난황에 포함된 면역 단백질 IgY (Immunoglobulin Yolk)는 식품 단백질로 장내 면역 물질로 중요하다. IgY를 정제하기 위해 신선란의 노른자에 카리지난이나 아라빅검을 전처리 물질로 사용하였다. 전처리 후 FPLC (Fast Protein Liquid chromatography)의 DEAE (Diethylaminoethyl) Sepharose 칼럼에서 이온교환법에 의해 불순물을 제거하여 IgY를 얻고, GF HPLC (Gel Filtration High Performance Liquid Chromatography)로 IgY의 분자량을 측정하고 표준 IgY와 비교하여 IgY 단백질을 동정하였다. GF HPLC에서 IgY의 다양성을 발견하였고 IgY 단백질 군의 다양성을 IE HPLC (Ion Exchange High Performance Liquid Chromatography)에서 AX, CX, SCX 칼럼을 사용하여 pH, NaCl 농도를 바꾸어 조사하였다. AX를 사용하여 0.5M NaCl, pH=8 조건에서 3개의 IgY 피크를 분리하였고, SCX를 이용했을 때 0.5M NaCl, pH=5 조건에서도 3개의 IgY 피크를 분리할 수 있었다.

Buffeting response control of a long span cable-stayed bridge during construction using semi-active tuned liquid column dampers

  • Shum, K.M.;Xu, Y.L.;Guo, W.H.
    • Wind and Structures
    • /
    • 제9권4호
    • /
    • pp.271-296
    • /
    • 2006
  • The frequency of a traditional tuned liquid column damper (TLCD) depends solely on the length of liquid column, which imposes certain restrictions on its application to long span cable-stayed bridges during construction. The configuration of a cable-stayed bridge varies from different construction stages and so do its natural frequencies. It is thus difficult to apply TLCD with a fixed configuration to the bridge during construction or it is not economical to design a series of TLCD with different liquid lengths to suit for various construction stages. Semi-active tuned liquid column damper (SATLCD) with adaptive frequency tuning capacity is studied in this paper for buffeting response control of a long span cable-stayed bridge during construction. The frequency of SATLCD can be adjusted by active control of air pressures inside the air chamber at the two ends of the container. The performance of SATLCD for suppressing combined lateral and torsional vibration of a real long span cable-stayed bridge during construction stage is numerically investigated using a finite element-based approach. The finite element model of SATLCD is also developed and incorporated into the finite element model of the bridge for predicting buffeting response of the coupled SATLCD-bridge system in the time domain. The investigations show that with a fixed container configuration, the SATLCD with adaptive frequency tuning can effectively reduce buffeting response of the bridge during various construction stages.

아음속 유동장에 수직분사시 오리피스 내부유동 효과에 대한 연구 (Effects of Orifice Internal Flow on Transverse Injection into Subsonic Crossflows)

  • 김정훈;안규복;윤영빈
    • 한국추진공학회지
    • /
    • 제7권1호
    • /
    • pp.28-39
    • /
    • 2003
  • 본 연구에서는 캐비테이션과 수력튀김과 같은 유동 현상이 수직 분사된 액체 제트의 분열에 미치는 영향을 살펴보았다. 오리피스 지름, 오리피스의 길이대 지름비, 오리피스 입구의 형상 그리고 배출 압력을 변화시켜가며 내부 유동 변화를 살피고 수직분사시 액주의 분열 거리와 제적을 구하여 기존의 연구 결과와 비교하고 분석하였다. 실험 결과 곡률이 없는 경우(sharp edged)의 오리피스에서는 어느 정도 이상의 압력에서 모두 캐비테이션이 발생하였고 곡률이 없는 경우 중 길이대 지름비가 작은 오리피스에선 캐비테이션 성장에 의한 수력튀김(hydraulic flip)현상도 관찰할 수 있었다 수직분사시 캐비테이션이 성장할수록 그리고 수력튀김 현상이 나타날 때 액주의 분열거리는 상당히 감소한다는 것을 알 수 있었다. 하지만 곡률이 있는 경우와 없는 경우 모두 유량 계수를 고려한 유효지름과 유효 모멘텀 플럭스 비에 대해 거의 같은 궤적 형상을 나타낸다는 것을 알 수 있었다.

Separation of Burnup Monitors in Spent Nuclear Fuel Samples by Liquid Chromatography

  • Joe, Kih-Soo;Jeon, Young-Shin;Kim, Jung-Suck;Han, Sun-Ho;Kim, Jong-Gu;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.569-574
    • /
    • 2005
  • A coupled column liquid chromatography system was applied for the separation of the burnup monitors in spent nuclear fuel sample solutions. A reversed phase column was studied for the adsorption behavior of uranyl ions using alpha-hydroxyisobutyric acid as an eluent and used for the separation of plutonium and uranium. A cation exchange column prepared by coating 1-eicosylsulfate onto the reversed phase column was used for the separation of the lanthanides. In addition, retention of Np was checked with the reversed phase column and cation exchange column, respectively, according to the oxidation states to observe the interference effect for the separation of burnup monitors. This chromatography system showed a great reduction in separation time compared to a conventional anion exchange method. A good agreement from the burnup data was obtained between for this method and a conventional anion exchange method to within 1% of a difference for the spent nuclear fuel samples of about 40 GWD/MTU.

Isolation of ginsenosides Rb1, Rb2, Rc Rd, Re, Rf and Rg1 from cinseng root by high performance liquid chromatography

  • Paik, Nam-Ho;Park, Man-Ki;Choi, Kang-Ju;Cho, Yung-Hyun
    • Archives of Pharmacal Research
    • /
    • 제5권1호
    • /
    • pp.7-12
    • /
    • 1982
  • Ginsenosides Rb1, Rb2, Rc, Rd, Re, Rf and Rg1 were effectively isolated from ginseng root by preparative liquid chromatography (LC) on two PrepPAK-500/c18 cartridges in series and semipreparative LC on a .mu. Bondapak cabohydrate analysis column, a .mu.Bondapak C18 column or a .mu. Porasil column. The identities of the isolated ginsenosides were confirmed by analytical high-performance liquid chromatography (HPLC) and infrared spectrophotometry. By this method large scale isolation of pure ginsenosides was efficiently accomplished.

  • PDF

원통형 액적내의 표면장력 변화로 인한 흐름특성에 관한 실험적 연구 (Experimental study of the surface-tension driven flow in a cylindrical liquid column)

  • 이진호;강희찬;이동진
    • 대한기계학회논문집
    • /
    • 제11권4호
    • /
    • pp.629-636
    • /
    • 1987
  • An experiment is carried out to study the surface-tension driven flow characteristics in a cylindrical liquid column heated from above (which is the low gravity floating zone simulated on earth) with varing the aspect ratio and diameter of the liquid column. Hexadecane, octadecane, silicon oil(10cs), FC-40 and water are used as the test liquids. The free surface shape varies sinusoidally for Ma>M $a_{cr}$ and its frequency is found to be the same as that of temperature oscillation. It is verified that the surface temperature profile changes from linear to S-shaped profile for Ma>M $a_{cr}$ . The frequency of temperature oscillation decreases with increasing liquid volume, while its level increases. M $a_{cr}$ decreases with increasing aspect ratio, and also decreases with increasing Prandtl number in the range of 25