• 제목/요약/키워드: Liquid chromatography coupled with mass spectrometry

검색결과 126건 처리시간 0.03초

Putative multiple reaction monitoring strategy for the comparative pharmacokinetics of postoral administration Renshen-Yuanzhi compatibility through liquid chromatography-tandem mass spectrometry

  • Sun, Yufei;Feng, Guifang;Zheng, Yan;Liu, Shu;Zhang, Yan;Pi, Zifeng;Song, Fengrui;Liu, Zhiqiang
    • Journal of Ginseng Research
    • /
    • 제44권1호
    • /
    • pp.105-114
    • /
    • 2020
  • Background: Exploring the pharmacokinetic (PK) changes of various active components of single herbs and their combinations is necessary to elucidate the compatibility mechanism. However, the lack of chemical standards and low concentrations of multiple active ingredients in the biological matrix restrict PK studies. Methods: A putative multiple reaction monitoring strategy based on liquid chromatography coupled with mass spectrometry (LC-MS) was developed to extend the PK scopes of quantification without resorting to the use of chemical standards. First, the compounds studied, including components with available reference standard (ARS) and components lacking reference standard (LRS), were preclassified to several groups according to their chemical structures. Herb decoctions were then subjected to ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry analysis with appropriate collision energy (CE) in MS2 mode. Finally, multiple reaction monitoring transitions transformed from MS2 of ultrahigh-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry were used for ultrahigh-performance liquid chromatography coupled with triple quadrupole mass spectrometry to obtain the mass responses of LRS components. LRS components quantification was further performed by developing an assistive group-dependent semiquantitative method. Results: The developed method was exemplified by the comparative PK process of single herbs Radix Ginseng (RG), Radix Polygala (RP), and their combinations (RG-RP). Significant changes in PK parameters were observed before and after combination. Conclusion: Results indicated that Traditional Chinese Medicine combinations can produce synergistic effects and diminish possible toxic effects, thereby reflecting the advantages of compatibility. The proposed strategy can solve the quantitative problem of LRS and extend the scopes of PK studies.

Tentative identification of 20(S)-protopanaxadiol metabolites in human plasma and urine using ultra-performance liquid chromatography coupled with triple quadrupole time-of-flight mass spectrometry

  • Ling, Jin;Yu, Yingjia;Long, Jiakun;Li, Yan;Jiang, Jiebing;Wang, Liping;Xu, Changjiang;Duan, Gengli
    • Journal of Ginseng Research
    • /
    • 제43권4호
    • /
    • pp.539-549
    • /
    • 2019
  • Background: 20(S)-Protopanaxadiol (PPD), the aglycone part of 20(S)-protopanaxadiol ginsenosides, possesses antidepressant activity among many other pharmacological activities. It is currently undergoing clinical trial in China as an antidepressant. Methods: In this study, an ultra-performance liquid chromatography coupled with triple quadrupole time-of-flight mass tandem mass spectrometry method was established to identify the metabolites of PPD in human plasma and urine following oral administration in phase IIa clinical trial. Results: A total of 40 metabolites in human plasma and urine were identified using this method. Four metabolites identified were isolated from rat feces, and two of them were analyzed by NMR to elucidate the exact structures. The structures of isolated compounds were confirmed as (20S,24S)-epoxydammarane-12,23,25-triol-3-one and (20S,24S)-epoxydammarane-3,12,23,25-tetrol. Both compounds were found as metabolites in human for the first time. Upon comparing our findings with the findings of the in vitro study of PPD metabolism in human liver microsomes and human hepatocytes, metabolites with m/z 475.3783 and phase II metabolites were not found in our study whereas metabolites with m/z 505.3530, 523.3641, and 525.3788 were exclusively detected in our experiments. Conclusion: The metabolites identified using ultra-performance liquid chromatography coupled with triple quadrupole time-of-flight mass spectrometry in our study were mostly hydroxylated metabolites. This indicated that PPD was metabolized in human body mainly through phase I hepatic metabolism. The main metabolites are in 20,24-oxide form with multiple hydroxylation sites. Finally, the metabolic pathways of PPD in vivo (human) were proposed based on structural analysis.

Determination of Sulfonamides in Meat by Liquid Chromatography Coupled with Atmospheric Pressure Chemical Ionization Mass Spectrometry

  • Kim, Dal-Ho;Choi, Jong-Oh;Kim, Jin-Seog;Lee, Dae-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1590-1594
    • /
    • 2002
  • Liquid chromatography/atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) has been used for the determination of sulfonamides in meat. Five typical sulfonamides were selected as target compounds, and beef meat was selected as a matrix sample. As internal standards, sulfapyridine and isotope labeled sulfamethazine (${13}^C_6$-SMZ) were used. Compared to the results of recent reports, our result have shown improved precision to a RSD of 1.8% for the determination of sulfamethazine spiked with 75 ng/g level in meat.

Possibilities of Liquid Chromatography Mass Spectrometry (LC-MS)-Based Metabolomics and Lipidomics in the Authentication of Meat Products: A Mini Review

  • Harlina, Putri Widyanti;Maritha, Vevi;Musfiroh, Ida;Huda, Syamsul;Sukri, Nandi;Muchtaridi, Muchtaridi
    • 한국축산식품학회지
    • /
    • 제42권5호
    • /
    • pp.744-761
    • /
    • 2022
  • The liquid chromatography mass spectrometry (LC-MS)-based metabolomic and lipidomic methodology has great sensitivity and can describe the fingerprint of metabolites and lipids in pork and beef. This approach is commonly used to identify and characterize small molecules such as metabolites and lipids, in meat products with high accuracy. Since the metabolites and lipids can be used as markers for many properties of a food, they can provide further evidence of the foods authenticity claim. Chromatography coupled to mass spectrometry is used to separate lipids and metabolites from meat samples. The research data usually is compared to lipid and metabolite databases and evaluated using multivariate statistics. LC-MS instruments directly connected to the metabolite and lipid databases software can be used to assess the authenticity of meat products. LC-MS has good selectivity and sensitivity for metabolomic and lipidomic analysis. This review highlighted the combination of metabolomics and lipidomics can be used as a reference for analyzing authentication meat products.

Simple and Robust Measurement of Blood Plasma Lysophospholipids Using Liquid Chromatography Mass Spectrometry

  • Ji, Dong Yoon;Lee, Chang-Wan;Park, Se Hee;Lee, Eun Jig;Lee, Do Yup
    • Mass Spectrometry Letters
    • /
    • 제8권4호
    • /
    • pp.109-113
    • /
    • 2017
  • Single analytical procedure including extraction, liquid chromatography, and mass spectrometric analysis was evaluated for the simultaneous measurement of lysophospholipids (LPLs). LPLs, particularly, lysophosphatidic acids (LPA) and sphingosine 1-phosphate (S1P) are lipid messengers ubiquitously found in various biological matrix. The molecular species mediate important physiological roles in association with many diseases (e.g. cancer, inflammation, and neurodegenerative disease), which emphasize the significance of the simple and reliable analytical method for biomarker discovery and molecular mechanistic understanding. Thus, we developed analytical method mainly focusing on, but not limited by those lipid species S1P and LPA using reverse phase liquid chromatography-tandem mass spectrometry (RPLC-ESI-MS-MS). Extraction method was modified based on Folch method with optimally minimal level of ionization additive (ammonium formate 10 mM and formic acid). Reverse-phase liquid-chromatography was applied for chromatographical separation in combination with negative ionization mode electrospray-coupled Orbitrap mass spectrometry. The method validation was performed on human blood plasma in a non-targeted lipid profiling manner with full-scan MS mode and data-dependent MS/MS. The proposed method presented good inter-assay precision for primary targets, S1P and LPA. Subsequent analysis of other types of LPLs identified a broad range of lysophosphatidylcholines (LPCs) and lysophosphatidyl-ethanolamines (LPEs).

Effect of Stewing Time on the Small Molecular Metabolites, Free Fatty Acids, and Volatile Flavor Compounds in Chicken Broth

  • Rong Jia;Yucai Yang;Guozhou Liao;Yuan Yang;Dahai Gu;Guiying Wang
    • 한국축산식품학회지
    • /
    • 제44권3호
    • /
    • pp.651-661
    • /
    • 2024
  • Chicken broth has a taste of umami, and the stewing time has an important effect on the quality of chicken broth, but there are fewer studies on the control of the stewing time. Based on this, the study was conducted to analyze the effects of different stewing times on the sensory, small molecular metabolites, free fatty acids, and volatile flavor compounds contents in chicken broths by liquid chromatography-quadrupole/time-of-flight mass spectrometry, gas chromatography-mass spectrometry, headspace solid-phase microextraction, and gas chromatography-mass spectrometry. Eighty-nine small molecular metabolites, 15 free fatty acids, and 86 volatile flavor compounds were detected. Palmitic and stearic acids were the more abundant fatty acids, and aldehydes were the main volatile flavor compounds. The study found that chicken broth had the best sensory evaluation, the highest content of taste components, and the richest content of volatile flavor components when the stewing time was 2.5 h. This study investigated the effect of stewing time on the quality of chicken broth to provide scientific and theoretical guidance for developing and utilizing local chicken.

Transformation of dissolved organic matter in a constructed wetland: A molecular-level composition analysis using pyrolysis-gas chromatography mass spectrometry

  • Park, Jongkwan;Choi, Mijin;Cho, Jaeweon;Chon, Kyongmi
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.390-396
    • /
    • 2018
  • This study investigated the transformation of dissolved organic matter (DOM) in a free-water surface flow constructed wetland. Pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) coupled with preparative high-performance liquid chromatography (prep-HPLC) was used to analyze the compositions of biopolymers (polysaccharides, amino sugars, proteins, polyhydroxy aromatics, lipids and lignin) in DOM according to the molecular size at three sampling points of the water flow: inflow, midflow, and outflow. The prep-HPLC results verified the decomposition of DOM through the decrease in the number of peaks from three to one in the chromatograms of the sampling points. The Py-GC/MS results for the degradable peaks indicated that biopolymers relating to polysaccharides and proteins gradually biodegraded with the water flow. On the other hand, the recalcitrant organic fraction (the remaining peak) in the outflow showed a relatively high concentration of aromatic compounds. Therefore, the ecological processes in the constructed wetland caused DOM to become more aromatic and homogeneous. This indicated that the constructed wetland can be an effective buffer area for releasing biochemically stable DOM, which has less influence on biological water quality indicators, e.g., biochemical oxygen demand, into an aquatic ecosystem.

Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry

  • Jang, Haejong;Mai, Xuan-Lan;Lee, Gunhee;Ahn, Jae Hyoung;Rhee, Jongsook;Truong, Quoc-Ky;Vinh, Dinh;Hong, Jongki;Kim, Kyeong Ho
    • Mass Spectrometry Letters
    • /
    • 제9권4호
    • /
    • pp.95-99
    • /
    • 2018
  • An innovative, simple, and rapid assay method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the simultaneous determination of eight statin drugs in human urine. A simple sample clean-up procedure using the "dilute and shoot" (DAS) approach enabled a fast and reliable analysis. The influence of the dilution factor was investigated to ensure detectability and reduce the matrix effect. Chromatographic separation was performed on a Phenomenex Kinetex C18 column ($50{\times}3.0mm$ i.d., $2.6{\mu}m$) using an elution gradient of mobile phase A composed of 0.1% acetic acid, and mobile phase B composed of acetonitrile, at a flow rate of 0.35 mL/min. Quantitation was performed on a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode using electrospray ionization in positive ion mode. The total chromatographic run time was 15 min. The method was validated for selectivity, sensitivity, recovery, linearity, accuracy, precision, and stability. The present method was successfully applied to the analysis of Rosuvastatin in urine samples after oral administration to healthy human subjects.

Determination of Corticosteroids in Moisturizers by LC-MS/MS

  • Park, Sumin;Choi, Gye Young;Lee, Seon-Ah;Kim, Hyun Jeong;Yum, Hye Yung;Paeng, Ki-Jung
    • Mass Spectrometry Letters
    • /
    • 제7권1호
    • /
    • pp.26-29
    • /
    • 2016
  • Simultaneous determination of three corticosteroids (clobetasol propionate, betamethasone dipropionate, fluticasone propionate) in moisturizers was performed by using liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS). Sample preparation was conducted by the liquid-liquid extraction (LLE). Moisturizers include emulsifying agent and it forms micelles. In order to improve the extraction efficiency of corticosteroids trapped in micelle, newly developed-optimized extraction conditions which can remove the matrix effect from moisturizers was applied with various pH conditions in LLE extraction stage of sample preparation. Thus, the addition of 10 μL of 1 M HCl into moisturizers sample before extraction could improve the extraction efficiency. For the quantitative analysis, SRM table that contained specific transition of all of target corticosteroids was created. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), limit of quantization (LOQ) and recovery. Over the 0.99 r2 value was obtained in calibration standard range. Effective accuracy and precision were also obtained. LODs were below 31 ng/mL and LOQs were estimated below 94 ng/mL for all corticosteroids tested.

A rapid separation of Cs, Sr and Ba using gas pressurized extraction chromatography with inductively coupled plasma-mass spectrometry

  • Sojin Jeong;Jihye Kim;Hanul Cho;Hwakyeung Jeong;Byungman Kang;Sang Ho Lim
    • 분석과학
    • /
    • 제37권2호
    • /
    • pp.123-129
    • /
    • 2024
  • We present a rapid method for the determination of Cs, Sr, and Ba, heat generators found in highly active liquid wastes, by gas-pressurized extraction chromatography (GPEC) using a column containing a cation-exchange resin. GPEC is a microscale column chromatographic technique that uses a constant flow rate of solvent (0.07 mL/min) with pressurized nitrogen gas supplied through a valve. In particular, because this method uses a small sample volume (a few hundred microliters), it produces less chemical waste and allows for faster separation compared to traditional column chromatography. In this study, we evaluated the separation of Cs, Sr, and Ba using GPEC. The eluate from the column (GPEC or conventional column chromatography) was quantitatively analyzed using inductively coupled plasma-mass spectrometry to measure the column recovery and precision. The column reproducibility of the proposed GPEC system (RSDs of recoveries) ranged from 2.7 to 4.1 %, and the column recoveries for the three elements ranged from 72 to 98% when aqueous HCl was used as the eluent. The GPEC results are slightly different in efficiency and separation resolution compared to those of conventional column chromatography because of the differences in the eluent flow rate as well as the internal diameter and length of the column. However, the two methods had similar recoveries for Cs and Sr, and the precision of GPEC was improved by two-fold. Remarkably, the solvent volume required for GPEC analysis was five times lower than that of the conventional method, and the total analysis time was 11 times shorter.